Sentinox (STX) is an acid-oxidizing solution containing hypochlorous acid in spray whose virucidal activity against SARS-CoV-2 has been demonstrated. In this paper, results of a randomized controlled trial (RCT) on the efficacy of STX in reducing viral load in mild COVID-19 patients (NCT04909996) and a complementary in vitro study on its activity against different respiratory viruses are reported. In the RCT, 57 patients were randomized (1:1:1) to receive STX three (STX-3) or five (STX-5) times/day plus standard therapy or standard therapy only (controls). Compared with controls, the log10 load reduction in groups STX-3 and STX-5 was 1.02 (p = 0.14) and 0.18 (p = 0.80), respectively. These results were likely driven by outliers with extreme baseline viral loads. When considering subjects with baseline cycle threshold values of 20–30, STX-3 showed a significant (p = 0.016) 2.01 log10 reduction. The proportion of subjects that turned negative by the end of treatment (day 5) was significantly higher in the STX-3 group than in controls, suggesting a shorter virus clearance time. STX was safe and well-tolerated. In the in vitro study, ≥99.9% reduction in titers against common respiratory viruses was observed. STX is a safe device with large virucidal spectrum and may reduce viral loads in mild COVID-19 patients.
Electroencephalography (EEG) continues to be a pivotal investigation in children with epilepsy, providing diagnostic evidence and supporting syndromic classification. In the pediatric population, electroencephalographic recordings are frequently performed during sleep, since this procedure reduces the number of artifacts and activates epileptiform abnormalities. To date, no shared guidelines are available for sleep induction in EEG. Among the interventions used in the clinical setting, melatonin and sleep deprivation represent the most used methods. The main purpose of this study is to test the non-inferiority of 3–5 mg melatonin versus sleep deprivation in achieving sleep in nap electroencephalography in children and young adult patients with epilepsy. To test non-inferiority, a randomized crossover trial is proposed where 30 patients will be randomized to receive 3–5 mg melatonin or sleep deprivation. Each enrolled subject will perform EEG recordings during sleep in the early afternoon for a total of 60 EEGs. In the melatonin group, the study drug will be administered a single oral dose 30 min prior to the EEG recording. In the sleep deprivation group, parents will be required to subject the child to sleep deprivation the night before registration. Urinary and salivary concentrations of melatonin and of its main metabolite 6-hydroxymelatonin will be determined by using a validated LC-MS method. The present protocol aims to offer a standardized protocol for sleep induction to be applied to EEG recordings in those of pediatric age. In addition, melatonin metabolism and elimination will be characterized and its potential interference in interictal abnormalities will be assessed.
This study describes the development and validation of a fully automated workflow for serum sample preparation, enabling the quantitative determination of cannabidiol (CBD) and its active metabolite, 7-hydroxy-CBD, via liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) analysis. Implemented on an automated platform, the workflow performs key steps such as solvent dispensing, mixing, centrifugation, filtration, and supernatant transfer, producing 96-well plates ready for analysis. Human serum samples were obtained from patients with epilepsy treated with CBD. All samples were processed using both manual and automated methods to evaluate method agreement. Quantification was performed by LC–MS/MS with CBD-d3 as the internal standard (IS). Method validation was conducted in accordance with European Medicine Agency (EMA) guidelines, confirming that the automated protocol meets the recommended acceptance criteria for both intraday and interday precision and accuracy. Calibration curves demonstrated excellent linearity across the concentration ranges. Comparative analysis using Passing–Bablok regression and Bland–Altman plots demonstrated strong agreement between the methods. These findings support the clinical applicability of the automated method for the therapeutic drug monitoring (TDM) of CBD and 7-hydroxy-CBD, and its robust performance and scalability provide a solid foundation for the development of an expanded analytical panel covering a broader range of antiseizure medications (ASMs), enabling more standardized TDM protocols in clinical practice.