Microwave imaging systems show potential as replacements for commonly used stroke diagnostic systems. We developed and tested a 10-port microwave system on a liquid head phantom with ischemic and hemorrhagic strokes of varying sizes and positions. This system allows for visualization of changes in dielectric parameters using the TSVD Born approximation, enabling recognition of stroke position and size from the resulting images. The SVM algorithm effectively distinguishes between ischemic and hemorrhagic strokes, achieving 98% accuracy on experimental data, with 99% accuracy in ischemic scenarios and 97% in hemorrhagic scenarios. Using the TSVD Born algorithm, it was possible to precisely image changes in the absolute permittivity of different stroke locations; however, changes in stroke size were more apparent in the variations of absolute permittivity than in the reconstructed stroke size within the antenna plane. Outside this plane, changes in the S-parameters decreased depending on the distance and size of the stroke, making detection and classification more difficult. One ring of antennas around the head proved insufficient, prompting us to focus on developing a system with antennas positioned around the entire head.
1 January 2026 in IEEE Transactions on Antennas and Propagation
Microwave imaging (MWI) offers a promising non-invasive approach for temperature monitoring during hyperthermia (HT) therapy. In this work, we investigate the extension of a clinical superficial HT system to facilitate non-invasive temperature assessment using microwave differential imaging. The integration of certified therapeutic technology with non-invasive monitoring represents an innovative step toward increasing the safety and effectiveness of clinical HT. A major challenge arises from the target region being located beneath a large-area applicator, which complicates the optimal placement of the imaging antennas and reduces system sensitivity. To address this, we evaluated the concept both numerically and experimentally using transmission coefficient thresholding (TCT) and multi-frequency imaging approaches. Experimental investigations focused on TCT index selection and the impact of frequency bandwidth on reconstruction quality. The results show that TCT improves spatial localization and yields a higher reconstruction intensity compared to truncated singular value decomposition (TSVD). Moreover, multi-frequency imaging in the range 0.6 – 0.8 GHz provided optimal performance. For temperature estimation, the single-frequency approach (0.7 GHz) achieved a low temperature estimation error but exhibited a less stable temperature estimation behavior. The multi-frequency approach (0.7 – 1 GHz) showed a higher temperature estimation error but demonstrated improved stability between the estimated and true temperatures. The proposed MWI framework demonstrates significant potential for integration into clinical HT workflows, offering enhanced temperature monitoring capabilities to improve treatment safety and efficacy.