16 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
ZLZdenek Linha
Zdenek Linha
JVJan Vrba
Jan Vrba
JKJakub Kollár
Jakub Kollár
Ondrej FiserOndrej Fiser
Ondrej Fiser
TPTomas Pokorny
Tomas Pokorny
DVDavid Vrba
David Vrba
Knowledge of the dielectric parameters of biological tissues is important in a wide range of medical applications of electromagnetic fields. Commercial systems using high-quality vector network analyzers (VNA) are expensive and can be a barrier to the development of existing and emerging applications. Therefore, the main objective of this work was to investigate the potential of using inexpensive VNA, which is available on the market, to measure the dielectric parameters of biological tissues. To accomplish this task, a system for the measurement of dielectric properties of biological tissues in the frequency range from 70 MHz to 3 GHz using inexpensive VNA was developed and presented. The system consists of pocketVNA 2.0 and a custom-made coaxial reflection probe with a diameter of 2.2 mm. The virtual line model of the coaxial probe was used to convert the measured reflection coefficients to the complex permittivity. A total of five ex-vivo tissues (heart, muscle, liver, kidney cortex, and fat) and two standard liquids (isopropanol and ethanol) were measured. The lower accuracy and lower signal-to-noise ratio of the inexpensive VNA were compensated for by post-processing of the measured data, including a time-domain gating and fitting of the evaluated dielectric properties to the Cole-Cole and Debye models for tissues and standard liquids, respectively. The measurement results were compared to the results obtained with a commercial measurement system, and both the standard deviation and mean absolute percentage error (MAPE) are evaluated and presented. The lowest achieved MAPE of biological tissues was for fitted relative permittivity 4.35% (fat, f < 200 MHz) and 0.66% (kidney cortex, f > 200 MHz) and for fitted equivalent electrical conductivity 2.58% (heart, f < 200 MHz) and 3.83% (heart, f > 200 MHz).

27 October 2022 in Cancers
Verified
Journal Article
Open access
PDF file
JKJakub Kollár
Jakub Kollár
TDTomas Drizdal
Tomas Drizdal
JVJan Vrba
Jan Vrba
DVDavid Vrba
David Vrba
TPTomas Pokorny
Tomas Pokorny
Ondrej FiserOndrej Fiser
Ondrej Fiser
Thermal ablation is a well-known method used in interventional radiology to treat cancer. The treatment success is closely related to the exact catheter location in the treated area. Current navigation methods are based mostly on ultrasound or computed tomography. This work explores the possibility of tracking the catheter position during ablation treatment of hepatocellular carcinomas (HCC) using an ultra-wideband (UWB) antenna array and microwave radar imaging based on the “Delay and Sum” (DAS) algorithm. The feasibility was first numerically studied on a simple homogeneous liver model. A heterogeneous anthropomorphic 3D model of the treated region consisting of the main organs within the treated area was then used. Various standard radiofrequency ablation (RFA) catheters were placed virtually in the heterogeneous model. The location and orientation of the antenna elements of the developed imaging system and the applied frequency band were studied. Subsequently, an experimental setup consisting of a 3D printed homogeneous anthropomorphic model, eight UWB dipole antennas, and catheters was created and used in a series of measurements. The average accuracy determining the catheter position from simulated and experimental data was 3.88 ± 0.19 and 6.13 ± 0.66 mm, which are close to the accuracy of clinical navigation systems.

12 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
TPTomas Pokorny
Tomas Pokorny
JRJan Rédr
Jan Rédr
HLHana Laierova
Hana Laierova
BSBarbora Smahelova
Barbora Smahelova
JKJakub Kollár
Jakub Kollár
Microwave imaging systems show potential as replacements for commonly used stroke diagnostic systems. We developed and tested a 10-port microwave system on a liquid head phantom with ischemic and hemorrhagic strokes of varying sizes and positions. This system allows for visualization of changes in dielectric parameters using the TSVD Born approximation, enabling recognition of stroke position and size from the resulting images. The SVM algorithm effectively distinguishes between ischemic and hemorrhagic strokes, achieving 98% accuracy on experimental data, with 99% accuracy in ischemic scenarios and 97% in hemorrhagic scenarios. Using the TSVD Born algorithm, it was possible to precisely image changes in the absolute permittivity of different stroke locations; however, changes in stroke size were more apparent in the variations of absolute permittivity than in the reconstructed stroke size within the antenna plane. Outside this plane, changes in the S-parameters decreased depending on the distance and size of the stroke, making detection and classification more difficult. One ring of antennas around the head proved insufficient, prompting us to focus on developing a system with antennas positioned around the entire head.

13 December 2024 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Open access
JKJakub Kollár
Jakub Kollár
MNMarek Novak
Marek Novak
MBMilan Babak
Milan Babak
TDTomas Drizdal
Tomas Drizdal
JVJan Vrba
Jan Vrba
Ondrej FiserOndrej Fiser
Ondrej Fiser
Ultra-wideband (UWB) radar differential imaging has a potential to be one of non-invasive, real-time, and non-ionizing methods for radiofrequency ablation (RFA) monitoring. In this study we developed a novel 3D UWB radar system for monitoring of the ablation zones (AZ) sizes and shapes. The system was first numerically tested on both homogeneous and heterogeneous patient models, followed by corresponding experiments. We applied a 3D Delay-and-Sum (DAS) algorithm to reconstruct and locate AZs, supported by an original method to determine average permittivity for heterogeneous DAS reconstructions. Additionally, an algorithm estimating the AZ size and shape was developed. The system demonstrated high precision with a monitoring error of 1.2 ± 0.9 mm in simulations and 1.3 ± 0.8 mm in ex vivo experiments. AZ volume and shape were approximated with relative errors of 14.8 ± 9.5 % in numerical models and 29.6 ± 24.3 % in experiments. These results indicate that the developed UWB radar system is a promising method for accurate RFA monitoring.

26 June 2025 in Physica Medica
Verified
Journal Article
Open access
TDTomas Drizdal
Tomas Drizdal
MPMargarethus M. Paulides
Margarethus M. Paulides
DJDaniel de Jong
Daniel de Jong
MNMarek Novak
Marek Novak
TPTomas Pokorny
Tomas Pokorny
GRGerard C. van Rhoon
Gerard C. van Rhoon

1 January 2026 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Open access
JRJan Rédr
Jan Rédr
ZLZdenek Linha
Zdenek Linha
JKJakub Kollár
Jakub Kollár
BSBarbora Smahelova
Barbora Smahelova
TPTomas Pokorny
Tomas Pokorny
JVJan Vrba
Jan Vrba