Mijung Jang

Dr. Mijung Jang

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2022 in Radiology
Verified
Journal Article
Closed access
BKBo Ra Kwon
Bo Ra Kwon
SSSung Ui Shin
Sung Ui Shin
SKSoo-Yeon Kim
Soo-Yeon Kim
YCYunhee Choi
Yunhee Choi
NCNariya Cho
Nariya Cho
WMWoo Kyung Moon
Woo Kyung Moon
Microcalcifications on mammograms obtained before neoadjuvant chemotherapy (NAC), peritumoral edema on MRI scans obtained after NAC, and clinical-pathologic variables were associated with survival ... Background Little is known regarding findings at imaging associated with survival in patients with luminal breast cancer treated with neoadjuvant chemotherapy (NAC). Purpose To determine the relati...

4 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
YDYoon Ah Do
Yoon Ah Do
MJMijung Jang
Mijung Jang
BYBo La Yun
Bo La Yun
SSSung Ui Shin
Sung Ui Shin
BKBohyoung Kim
Bohyoung Kim
SKSun Mi Kim
Sun Mi Kim
The present study evaluated the diagnostic performance of artificial intelligence-based computer-aided diagnosis (AI-CAD) compared to that of dedicated breast radiologists in characterizing suspicious microcalcification on mammography. We retrospectively analyzed 435 unilateral mammographies from 420 patients (286 benign; 149 malignant) undergoing biopsy for suspicious microcalcification from June 2003 to November 2019. Commercial AI-CAD was applied to the mammography images, and malignancy scores were calculated. Diagnostic performance was compared between radiologists and AI-CAD using the area under the receiving operator characteristics curve (AUC). The AUCs of radiologists and AI-CAD were not significantly different (0.722 vs. 0.745, p = 0.393). The AUCs of the adjusted category were 0.726, 0.744, and 0.756 with cutoffs of 2%, 10%, and 38.03% for AI-CAD, respectively, which were all significantly higher than those for radiologists alone (all p < 0.05). None of the 27 cases downgraded to category 3 with a cutoff of 2% were confirmed as malignant on pathological analysis, suggesting that unnecessary biopsies could be avoided. Our findings suggest that the diagnostic performance of AI-CAD in characterizing suspicious microcalcification on mammography was similar to that of the radiologists, indicating that it may aid in making clinical decisions regarding the treatment of breast microcalcification.

1 October 2019 in Radiology
Verified
Journal Article
Closed access
HCHye Young Choi
Hye Young Choi
SKSun Mi Kim
Sun Mi Kim
MJMijung Jang
Mijung Jang
BYBo La Yun
Bo La Yun
EKEunyoung Kang
Eunyoung Kang
WMWoo Kyung Moon
Woo Kyung Moon
US-guided directional vacuum-assisted removal or US follow-up without intervention could be an alternative to surgical excision for benign breast papilloma without atypia. Background Recent studies suggest that US-guided directional vacuum-assisted removal (DVAR) is a satisfactory alternative to surgery for benign papilloma of the breast and recommend discretionary d...

17 August 2019 in La radiologia medica
Verified
Journal Article
Closed access
HAHye Shin Ahn
Hye Shin Ahn
MJMijung Jang
Mijung Jang
SKSun Mi Kim
Sun Mi Kim
BYBo La Yun
Bo La Yun
SLSoo Hyun Lee
Soo Hyun Lee

1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
SLSoo Hyun Lee
Soo Hyun Lee
MJMijung Jang
Mijung Jang
SKSun Mi Kim
Sun Mi Kim
BYBo La Yun
Bo La Yun
JRJiwon Rim
Jiwon Rim
HCHye Young Choi
Hye Young Choi
Lee SH, et al. Korean J Radiol. 2019 Jan;20(1):58-68. https://doi.org/10.3348/kjr.2018.0012

1 July 2019 in Ultrasonography
Verified
Journal Article
Open access
PDF file
GYGabin Yun
Gabin Yun
SKSun Mi Kim
Sun Mi Kim
BYBo La Yun
Bo La Yun
HAHye Shin Ahn
Hye Shin Ahn
MJMijung Jang
Mijung Jang
Purpose: The purpose of this study was to assess the reliability of automated breast ultrasound (ABUS) examinations of suspicious breast masses in comparison to handheld breast ultrasound (HHUS) with regard to Breast Imaging Reporting and Data System (BI-RADS) category assessment, and to investigate the factors affecting discrepancies in categorization. Methods: A total of 135 masses that were assessed as BI-RADS categories 4 and 5 on ABUS that underwent ultrasound (US)-guided core needle biopsy from May 2017 to December 2017 were included in this study. The BI-RADS categories were re-assessed using HHUS. Agreement of the BI-RADS categories was evaluated using kappa statistics, and the positive predictive value of each examination was calculated. Logistic regression analysis was performed to identify the mammography and US findings associated with discrepancies in the BI-RADS categorization. Results: The overall agreement between ABUS and HHUS in all cases was good (79.3%, kappa=0.61, P<0.001). Logistic regression analysis revealed that accompanying suspicious microcalcifications on mammography (odds ratio PR], 4.63; 95% confidence interval [CI], 1.83 to 11.71; P=0.001) and an irregular shape on US (OR, 5.59; 95% CI, 1.43 to 21.83; P=0.013) were associated with discrepancies in the BI-RADS categorization. Conclusion: The agreement between ABUS and HHUS examinations in the BI-RADS categorization of suspicious breast masses was good. The presence of suspicious microcalcifications on mammography and an irregular shape on US were factors associated with ABUS yielding a lower level of suspicion than HHUS in terms of the BI-RADS category assessment.