Kagan Berk

Dr. Kagan Berk

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MRMuhammad Hassan Razzaq
Muhammad Hassan Razzaq
OAOlugbenga Ayeni
Olugbenga Ayeni
SKSelin Köklü
Selin Köklü
KBKagan Berk
Kagan Berk
MZMuhammad Usama Zaheer
Muhammad Usama Zaheer
Sen SinanSen Sinan
Sen Sinan
This study investigates the potential of Selective Laser Melting (SLM) to tailor the surface characteristics of Ti6Al4V directly during fabrication, eliminating the need for post-processing treatments potentially for dental implants. By adjusting the Volumetric Energy Density (VED) through controlled variations in the laser scanning speed, we achieved customized surface textures at both the micro- and nanoscale levels. SLM samples fabricated at moderate VED levels (50–100 W·mm3/s) exhibited optimized dual-scale surface roughness—a macro-roughness of up to 25.5–27.6 µm and micro-roughness of as low as 58.8–64.2 nm—resulting in significantly enhanced hydrophilicity, with water contact angles (WCAs) decreasing to ~62°, compared to ~80° on a standard grade 5 machined Ti6Al4V plate. The XPS analysis revealed that the surface oxygen content remains relatively stable at low VED values, with no significant increase. The surface topography plays a significant role in influencing the WCA, particularly when the VED values are low (below 200 W·mm3/s) during SLM, indicating the dominant effect of surface morphology over chemistry in these conditions. Biological assays using osteoblast-like MG-63 cells demonstrated that these as-built SLM surfaces supported a 1.5-fold-higher proliferation and improved cytoskeletal organization relative to the control, confirming the enhanced early cellular responses. These results highlight the capability of SLM to engineer bioactive implant surfaces through process-controlled morphology and chemistry, presenting a promising strategy for the next generation of dental implants suitable for immediate placement and osseointegration.

Verified
Journal Article
Open access
PDF file
KBKagan Berk
Kagan Berk
AÖAykut Can Önel
Aykut Can Önel
KOKarahan Ocak
Karahan Ocak
Yasemin TabakYasemin Tabak
Yasemin Tabak
GÖGökçe Özbay
Gökçe Özbay
Sen SinanSen Sinan
Sen Sinan
This study investigates the effects of post-processing on the surface roughness, wettability, and frictional behavior of selective laser-melted (SLM) cobalt–chromium–tungsten (CoCrW) alloys for orthodontic use. The SLM-CoCrW specimens were tested in as-manufactured, mechanically polished, and electropolished states. Surface characterization via stylus profilometry and atomic force microscopy (AFM) showed that both polishing methods reduced macro- and micro-scale roughness, with electropolishing producing the smoothest, most uniform topography. Static water contact angle (WCA) measurements revealed that mechanical polishing provided an optimal balance of roughness and hydrophilicity, resulting in the lowest friction, while ultrasmooth electropolished surfaces exhibited slightly higher friction due to increased hydrophobicity and a uniform Cr-rich oxide layer confirmed by X-ray photoelectron spectroscopy (XPS). XPS also indicated that electropolishing generated a homogenous chromium oxide passive film, whereas mechanical polishing left a chemically heterogeneous surface with exposed metallic sites. Importantly, performance is not governed solely by surface roughness; surface chemistry is equally critical, and both must be considered together—along with wettability and tribological behavior—to achieve optimal functional outcomes. From a clinical perspective, optimization of surface roughness and surface chemistry may result in decreased frictional resistance, improved sliding mechanics, and enhanced long-term performance of additively manufactured orthodontic components; however, the present study was restricted to in vitro characterization under simplified laboratory conditions, and further investigations involving artificial saliva, long-term aging, wear and clinical simulations are necessary to validate the translational relevance of these findings.