Implementation of hybrid energy system (HES) is generally considered as a promising way to satisfy the electrification requirements for remote areas. In the present study, a novel decision making methodology is proposed to identify the best compromise configuration of HES from a set of feasible combinations obtained from HOMER. For this purpose, a multi-objective function, which comprises four crucial and representative indices, is formulated by applying the weighted sum method. The entropy weight method is employed as a quantitative methodology for weighting factors calculation to enhance the objectivity of decision-making. Moreover, the optimal design of a stand-alone PV/wind/battery/diesel HES in Yongxing Island, China, is conducted as a case study to validate the effectiveness of the proposed method. Both the simulation and optimization results indicate that, the optimization method is able to identify the best trade-off configuration among system reliability, economy, practicability and environmental sustainability. Several useful conclusions are given by analyzing the operation of the best configuration.
This study presents a new control strategy for three‐level neutral point‐clamped pulse‐width modulated (PWM) rectifier. The relationship between instantaneous power and voltage vectors is derived mathematically from the model of three‐phase three‐level voltage source PWM rectifier, and a direct power control (DPC) scheme for three‐level PWM rectifier is presented. An optimal switching table is established, from which appropriate voltage vectors can be selected to control active and reactive power directly. Principle for vector switching to avoid excessive Δ V in phase and line‐to‐line voltages and balance strategy for the neutral point potential are also discussed. A digital‐signal‐processor‐based experimental system is developed to implement a series of experiments. The obtained results have verified the theoretical approach, and the three‐level PWM rectifier with proposed DPC exhibits advantages of simple algorithm and good dynamic performance, compared with conventional voltage‐oriented control.
To address the issue of negative damping instability easily induced by DC/DC converters under constant power load (CPL) in DC microgrids and to enhance the control robustness of the system under uncertainties such as parameter perturbations, this paper designs a controller based on the linear active disturbance rejection control (LADRC) theory. Firstly, by establishing an equivalent model of the DC microgrid with CPL, the intrinsic relationship between the equivalent incremental admittance of the hybrid load and the system damping is revealed. Subsequently, treating the nonlinear characteristics of the CPL and model parameter variations as external disturbances, the linear extended state observer (LESO) is employed to estimate and compensate for the total system disturbance in real time. This effectively eliminates the risk of negative damping instability caused by the CPL and enhances the system’s robustness against parameter variations. Then, theoretical analysis is conducted from three perspectives, the convergence of disturbance estimation error, the stability of the closed-loop system, and robustness against parameter variations, thereby ensuring the reliability of the proposed control strategy. Finally, the proposed control strategy is validated through simulations and experiments. The results confirm that, even in the presence of negative damping effects and parameter variations, the strategy can effectively maintain fast tracking and stable control of the output voltage.
The modular multi-active bridge (MMAB) converter—characterized by electrical isolation, modular design, high power density, and high efficiency—can be readily scaled to multiple DC ports through an internal shared high-frequency bus (HFB), establishing it as a viable topology for DC transformer (DCT) applications. However, its interconnection to a DC grid via low-damping inductors may provoke low-frequency oscillations and instability. To mitigate this issue, this paper employs a pole-zero cancellation approach to model the conventional constant-power control (CPC) loop as a second-order system, thereby elucidating the relationship between equivalent line impedance and stability. An active damping control strategy based on virtual impedance is then introduced, supported by systematic design guidelines for the damping compensation stage. Simulation and experimental results confirm that under weak damping conditions, the proposed method raises the damping coefficient to 0.707 and effectively suppresses low-frequency oscillations—all without altering physical line impedance, introducing additional power losses or requiring extra sensing devices—thereby markedly improving grid-connected stability.
For the high-voltage AC port of power electronic transformer (HVAC-PET) with three-phase independent DC buses on the low-voltage side, a decoupling control strategy, concerning the influence of grid voltage imbalance, three-phase active-load imbalance, and high-order harmonic distortion, is proposed in this paper to simultaneously realize the functions of active power control, reactive power compensation, and active power filtering. In the outer power control loop, according to the distribution rule of decoupled average active power components in three phases, stability control for the sum of cluster average active power flows is realized by injecting positive-sequence active current, so as to control the average cluster voltage (i.e., the average of all the DC-link capacitor voltages), and by injecting negative-sequence current, the cluster average active power flows can be controlled individually to balance the three cluster voltages (i.e., the average of the DC-link capacitor voltages in each cluster). The negative-sequence reactive power component is considered to realize the reactive power compensation. In the inner current control loop, the fundamental and high-order harmonic components are uniformly controlled in the positive-sequence dq frame using the PI + VPIs (vector proportional integral) controller, and the harmonic filtering function is realized while the fundamental positive-sequence current is adjusted. Experiments performed on the 380 V/50 kVA laboratory HVAC-PET verify the effectiveness of the proposed control strategy.