To address the issue of negative damping instability easily induced by DC/DC converters under constant power load (CPL) in DC microgrids and to enhance the control robustness of the system under uncertainties such as parameter perturbations, this paper designs a controller based on the linear active disturbance rejection control (LADRC) theory. Firstly, by establishing an equivalent model of the DC microgrid with CPL, the intrinsic relationship between the equivalent incremental admittance of the hybrid load and the system damping is revealed. Subsequently, treating the nonlinear characteristics of the CPL and model parameter variations as external disturbances, the linear extended state observer (LESO) is employed to estimate and compensate for the total system disturbance in real time. This effectively eliminates the risk of negative damping instability caused by the CPL and enhances the system’s robustness against parameter variations. Then, theoretical analysis is conducted from three perspectives, the convergence of disturbance estimation error, the stability of the closed-loop system, and robustness against parameter variations, thereby ensuring the reliability of the proposed control strategy. Finally, the proposed control strategy is validated through simulations and experiments. The results confirm that, even in the presence of negative damping effects and parameter variations, the strategy can effectively maintain fast tracking and stable control of the output voltage.
The modular multi-active bridge (MMAB) converter—characterized by electrical isolation, modular design, high power density, and high efficiency—can be readily scaled to multiple DC ports through an internal shared high-frequency bus (HFB), establishing it as a viable topology for DC transformer (DCT) applications. However, its interconnection to a DC grid via low-damping inductors may provoke low-frequency oscillations and instability. To mitigate this issue, this paper employs a pole-zero cancellation approach to model the conventional constant-power control (CPC) loop as a second-order system, thereby elucidating the relationship between equivalent line impedance and stability. An active damping control strategy based on virtual impedance is then introduced, supported by systematic design guidelines for the damping compensation stage. Simulation and experimental results confirm that under weak damping conditions, the proposed method raises the damping coefficient to 0.707 and effectively suppresses low-frequency oscillations—all without altering physical line impedance, introducing additional power losses or requiring extra sensing devices—thereby markedly improving grid-connected stability.