View All Publications
5 September 2018 in Energies
Verified
Journal Article
Open access
PDF file
ELEnwen Li
Enwen Li
LWLinong Wang
Linong Wang
BSBin Song
Bin Song
SJSiliang Jian
Siliang Jian
Dissolved gas analysis (DGA) of the oil allows transformer fault diagnosis and status monitoring. Fuzzy c-means (FCM) clustering is an effective pattern recognition method, but exhibits poor clustering accuracy for dissolved gas data and usually fails to subsequently correctly classify transformer faults. The existing feasible approach involves combination of the FCM clustering algorithm with other intelligent algorithms, such as neural networks and support vector machines. This method enables good classification; however, the algorithm complexity is greatly increased. In this paper, the FCM clustering algorithm itself is improved and clustering analysis of DGA data is realized. First, the non-monotonicity of the traditional clustering membership function with respect to the sample distance and its several local extrema are discussed, which mainly explain the poor classification accuracy of DGA data clustering. Then, an exponential form of the membership function is proposed to obtain monotony with respect to distance, thereby improving the dissolved gas data clustering. Likewise, a similarity function to determine the degree of membership is derived. Test results for large datasets show that the improved clustering algorithm can be successfully applied for DGA-data-based transformer fault detection.

5 November 2018 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
LWLinong Wang
Linong Wang
ELEnwen Li
Enwen Li
BSBin Song
Bin Song
YFYaqi Fang
Yaqi Fang
Whether the equipment is charged or not is a working procedure that must be carried out to ensure the safety of personnel during the power failure maintenance work on the power transmission and transformation equipment. At present, UHV power transmission equipment mainly uses contact, non-contact electroscope to check whether the equipment is electrified. However, this type of electroscope needs a wide response range because the stray capacitance to ground is greatly affected by the actual working environment and operating position. At the same time, the contact type high voltage electroscope generally needs to be used with the insulated test pole. As the voltage level rises, the required safety distance increases. The length and deflection of the test pole cannot meet the requirements. The overall quality is larger and the operation is inconvenient. The use of material colour changes to indicate the charged state of the device is a promising technical means. Based on the electrochromic technology, this paper makes use of tungsten trioxide materials to prepare charged state indicator materials for UHV transmission equipment, and characterizes whether the equipment is charged by the colour change of materials. Experiments show the effectiveness of the material.

18 April 2017 in DEStech Transactions on Materials Science and Engineering
Verified
Journal Article
Closed access
PDF file
XLXiaochun Li
Xiaochun Li
LWLinong Wang
Linong Wang
ELEnwen Li
Enwen Li
BSBin Song
Bin Song
For the problems that electrical inspection technology can not meet the requirements of UHV power transmission equipment due to the rapid development of power grids, this paper proposed the method that determines whether the device is charging using photonic crystals electrochromic material. Prepared photonic crystal electrochromic material samples using the method of high temperature liquid phase synthesis and the discoloration performance testing based on magnetic stimulation conditions was carried out for the samples. The simulation and experiment results show that the material has a reversible color performance, it is possible to accurately indicate whether the device is charged, and has the advantages of high efficiency, easy operation.

18 April 2017 in DEStech Transactions on Materials Science and Engineering
Verified
Journal Article
Closed access
PDF file
KCKang Chen
Kang Chen
LWLinong Wang
Linong Wang
ELEnwen Li
Enwen Li
BSBin Song
Bin Song
Now, electroscope has disadvantage of large quality, inconvenient operation, and it has low quality of accuracy, adaptability, reliability and cost performance. In this paper, a new method for the identification of electricity test is presented. It uses electrochromic material for equipment electricity identification of UHV power transmission and transformation. When the device is charged, the material will change color as the charged signal; while the device is not charged, the material will return to the original color. The material has advantage of low energy consumption, no radiation, apparent identity, repeated use. This paper adopted three kinds of materials such as tungsten trioxide material, Ag-Polybutene (hereafter referred to as PB) composite material and graphene-Polyamide (hereafter referred to as PA) for production making and test. The results show that these three kinds of material have electricity identification performance, the properties of graphene-PA composites were the best, and it has the development prospect as eletrochromism material used for equipment electricity identification of UHV power transmission and transformation.

1 December 2017 in DEStech Transactions on Engineering and Technology Research
Verified
Journal Article
Closed access
PDF file
TLTong Lin
Tong Lin
BSBin Song
Bin Song
ELEnwen Li
Enwen Li
LWLi-Nong Wang
Li-Nong Wang
The three ratio method in dissolved gas analysis is a widely used method for transformer fault diagnosis, but the “000” and “011” code does not give its corresponding fault types. Since the missing data research is a small sample problem, it cannot be solved by traditional statistical and probabilistic laws. Therefore, grey relational analysis is introduced into grey system theory to study it. Research shows that the fault corresponding to the “000” code may be one of partial discharge or high temperature overheating, and the fault corresponding to the “011” code may be one of partial discharge, high energy discharge, low temperature overheating and high temperature overheating. By using grey relational analysis, the fault types of two missing codes can be further distinguished.