Rizky Ilhamsyah

Mr. Rizky Ilhamsyah

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
RIRizky Ilhamsyah
Rizky Ilhamsyah
JDJean-Marie D. Dimandja
Jean-Marie D. Dimandja
Peter HeskethPeter Hesketh
Peter Hesketh
Breath analysis has attracted a lot of interest for noninvasive health diagnostics method by detecting disease biomarkers. However, the exhaled breath collection process remains a challenge. Specifically, the effective separation of the water vapor from the breath sample, which is necessary to avoid humidity interference in gas detection system and to preserve the liquid condensate for other analysis. In this paper, an analytical model is developed to obtain the optimized condenser for portable breath collection system to effectively provide both dry gas phase sample and exhaled breath condensate. The mathematical model is verified by using a heated water bubbler as warm and humid air generator (in vitro). Furthermore, the performance of the device is tested by using actual human breath (in vivo). The in vitro test result shows the temperature and moisture concentration values have a good agreement with the measured values with margin of error ±15%, and ±30% for amount of collected condensate. The in vivo result shows, with the thermoelectric element cooled up to 8.5 °C, a moisture removal efficiency of 62.4% is achieved. In this case, the system can collect exhaled breath condensate of 0.457 ± 0.092 ml and dry gas (RH 47.8% at 27 °C) for 10 exhalations.

1 February 2024 in Journal of Chromatography Open
Verified
Journal Article
Open access
RIRizky Ilhamsyah
Rizky Ilhamsyah
DSDaniel R. Struk
Daniel R. Struk
CHChristopher A. Heist
Christopher A. Heist
PHPeter J. Hesketh
Peter J. Hesketh
JDJean-Marie D. Dimandja
Jean-Marie D. Dimandja

30 July 2025 in Separations
Verified
Journal Article
Open access
PDF file
DSDaniel Struk
Daniel Struk
RIRizky Ilhamsyah
Rizky Ilhamsyah
JDJean-Marie D. Dimandja
Jean-Marie D. Dimandja
Peter HeskethPeter Hesketh
Peter Hesketh
In this paper, the directed message-passing neural network architecture is used to predict several quantities of interest in gas chromatography: retention times, Clarke-Glew 3-point thermodynamic parameters for simulation, and retention indices. The retention index model was trained with 48,803 training samples and reached 1.9–2.6% accuracy, whereas the thermodynamic parameters and retention time were trained by using 230 training data samples yielding 17% accuracy. Furthermore, the accuracy as a function of the number of training samples is investigated, showing the necessity of large, accurate datasets for training deep learning-based models. Lastly, several uses of such a model for the identification of compounds and the optimization of GC parameters are discussed.

29 September 2026 in Metabolites
Verified
Journal Article
Open access
PDF file
SKSeibi Kobara
Seibi Kobara
MHMin Huang
Min Huang
RIRizky Ilhamsyah
Rizky Ilhamsyah
DSDaniel Struk
Daniel Struk
JDJohn Dimandja
John Dimandja
AEAnnette Esper
Annette Esper
Background/Objectives: Polydimethylsiloxane (PDMS) is a non-invasive and versatile material often used for non-invasive collection of skin-emitted volatile organic compounds (VOCs), with potential applicability in acute and pre-critical care settings. However, most existing PDMS-based methodologies rely on extensive sample preparation and environmental control, limiting their feasibility in time-sensitive clinical contexts. Methods: We conducted a proof-of-concept pilot case-series study in four healthy volunteers to evaluate whether a simplified skin-contact PDMS sampling procedure can capture detectable VOCs and preserve individual-level variation. PDMS strips were applied directly to the skin with minimal preparation, and collected VOCs were analyzed using gas chromatography–mass spectrometry. Donor-associated variability was assessed using Bray–Curtis dissimilarity, and variability in VOC detection was evaluated across body sites. Results: Skin-contact PDMS sampling detected 160 VOCs across four participants. The mean within-donor Bray–Curtis dissimilarity was 0.308, compared with a mean between-donor dissimilarity of 0.347. VOC detection variability differed across body sites, with lower coefficients of variation at the forehead, neck, and wrist than at the ankle. Conclusions: Under simplified sampling conditions, skin-contact PDMS captured individual-associated VOC profiles with lower within-donor variability than between-donor variability. These findings support the feasibility of PDMS-based skin VOC sampling in minimally controlled settings. Further validation in larger and clinically relevant cohorts is warranted to assess the utility of PDMS-sampled skin VOCs as potential biomarkers for early disease detection.

11 October 2025 in Journal of Chromatography A
Verified
Journal Article
Open access
RIRizky Ilhamsyah
Rizky Ilhamsyah
DSDaniel R. Struk
Daniel R. Struk
CHChristopher A. Heist
Christopher A. Heist
AAAlexander Travis Adams
Alexander Travis Adams
LBLou Ann Brown
Lou Ann Brown
PHPeter J. Hesketh
Peter J. Hesketh
In this paper, the non-targeted volatile organic compound (VOC) collection performance of a custom 75 % dehumidified alveolar breath sample collection system is evaluated. VOCs were captured using stir bar sorptive extraction (SBSE) and analysed with a thermal desorption unit paired with a multidimensional gas chromatography and mass spectrometry (TD-GC × GC-MS) instrument. A data-cleaning framework and software were developed to process the raw chromatographic data through mass spectra similarity thresholding and retention index matching. The VOC profile of the dehumidified alveolar breath was assessed by checking for 635 compounds identified in previous breath VOC analyses and 8 compounds from the peppermint initiative. The results showed the presence of 7 peppermint compounds across the volunteers' breath samples, with menthone, beta-pinene, and eucalyptol being the most consistently detected. From the screening, the database of 635 breath compounds revealed approximately 50-70 compounds with a high alveolar gradient in the volunteer's breath, predominantly consisting of hydrocarbons, ketones, alcohols, aldehydes, carboxylic acids, and nitrogen-containing compounds. Across all volunteers, monoterpenes, aromatic, and saturated hydrocarbons are consistently observed, which might be correlated with the collection process and the type of SBSE used.