Alexander Travis Adams

Dr. Alexander Travis Adams

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2015
Verified
Conference Paper
Open access
AAAlexander Travis Adams
Alexander Travis Adams
JCJean Costa
Jean Costa
MJMalte F. Jung
Malte F. Jung
TCTanzeem Choudhury
Tanzeem Choudhury
Persuasive technologies aim to influence user's behaviors. In order to be effective, many of the persuasive technologies developed so far relies on user's motivation and ability, which is highly variable and often the reason behind the failure of such technology. In this paper, we present the concept of Mindless Computing, which is a new approach to persuasive technology design. Mindless Computing leverages theories and concepts from psychology and behavioral economics into the design of technologies for behavior change. We show through a systematic review that most of the current persuasive technologies do not utilize the fast and automatic mental processes for behavioral change and there is an opportunity for persuasive technology designers to develop systems that are less reliant on user's motivation and ability. We describe two examples of mindless technologies and present pilot studies with encouraging results. Finally, we discuss design guidelines and considerations for developing this type of persuasive technology.

21 December 2022 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
YZYiran Zhao
Yiran Zhao
YTYujie Tao
Yujie Tao
GLGrace Le
Grace Le
RMRui Maki
Rui Maki
AAAlexander Travis Adams
Alexander Travis Adams
TCTanzeem Choudhury
Tanzeem Choudhury
We investigated affective touch as a new pathway to passively mitigate in-the-moment anxiety. While existing mobile interventions offer great promises for health and well-being, they typically focus on achieving long-term effects such as shifting behaviors. As such, most mobile interventions are not applicable to provide immediate help in acute conditions -- when a user experiences a high anxiety level during ongoing events (e.g., completing high-stake tasks or mitigating interpersonal conflicts). A few works have developed passive interventions that are effective in-the-moment by leveraging breathing regulations and biofeedback. In this paper, we drew on neuroscientific findings on affective touch, the slow stroking on hairy skin that can elicit innate pleasantness and evaluated affective touch as a mobile health intervention. To induce affective touch, we first engineered a wearable device that renders a soft stroking sensation on the user's forearm. Then, we conducted a between-group experiment, in which participants underwent high-stress situations with/without receiving affective touch and post-experiment interviews, with 24 participants. Our results showed that participants who received affective touch experienced lower state anxiety and the same physiological stress response level compared to the control group participants. We also found that affective touch facilitated emotion regulation by rendering pleasantness, providing emotional support, and shifting attention. Finally, we discussed the immediate effect of affective touch on anxiety and physiological stress, the benefits of affective touch as a passive intervention, and the implementation considerations to use affective touch in just-in-time systems.

22 April 2022 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
AAAlexander Travis Adams
Alexander Travis Adams
IMIlan Mandel
Ilan Mandel
YGYixuan Gao
Yixuan Gao
BHBryan W Heckman
Bryan W Heckman
RNRajalakshmi Nandakumar
Rajalakshmi Nandakumar
TCTanzeem Choudhury
Tanzeem Choudhury
Background: Many commodity pulse oximeters are insufficiently calibrated for patients with darker skin. We demonstrate a quantitative measurement of this disparity in peripheral blood oxygen saturation (SpO2) with a controlled experiment. To mitigate this, we present OptoBeat, an ultra–low-cost smartphone-based optical sensing system that captures SpO2 and heart rate while calibrating for differences in skin tone. Our sensing system can be constructed from commodity components and 3D-printed clips for approximately US $1. In our experiments, we demonstrate the efficacy of the OptoBeat system, which can measure SpO2 within 1% of the ground truth in levels as low as 75%. Objective: The objective of this work is to test the following hypotheses and implement an ultra–low-cost smartphone adapter to measure SpO2: skin tone has a significant effect on pulse oximeter measurements (hypothesis 1), images of skin tone can be used to calibrate pulse oximeter error (hypothesis 2), and SpO2 can be measured with a smartphone camera using the screen as a light source (hypothesis 3). Methods: Synthetic skin with the same optical properties as human skin was used in ex vivo experiments. A skin tone scale was placed in images for calibration and ground truth. To achieve a wide range of SpO2 for measurement, we reoxygenated sheep blood and pumped it through synthetic arteries. A custom optical system was connected from the smartphone screen (flashing red and blue) to the analyte and into the phone’s camera for measurement. Results: The 3 skin tones were accurately classified according to the Fitzpatrick scale as types 2, 3, and 5. Classification was performed using the Euclidean distance between the measured red, green, and blue values. Traditional pulse oximeter measurements (n=2000) showed significant differences between skin tones in both alternating current and direct current measurements using ANOVA (direct current: F2,5997=3.1170 × 105, P<.01; alternating current: F2,5997=8.07 × 106, P<.01). Continuous SpO2 measurements (n=400; 10-second samples, 67 minutes total) from 95% to 75% were captured using OptoBeat in an ex vivo experiment. The accuracy was measured to be within 1% of the ground truth via quadratic support vector machine regression and 10-fold cross-validation (R2=0.97, root mean square error=0.7, mean square error=0.49, and mean absolute error=0.5). In the human-participant proof-of-concept experiment (N=3; samples=3 × N, duration=20-30 seconds per sample), SpO2 measurements were accurate to within 0.5% of the ground truth, and pulse rate measurements were accurate to within 1.7% of the ground truth. Conclusions: In this work, we demonstrate that skin tone has a significant effect on SpO2 measurements and the design and evaluation of OptoBeat. The ultra-low-cost OptoBeat system enables smartphones to classify skin tone for calibration, reliably measure SpO2 as low as 75%, and normalize to avoid skin tone–based bias.

21 November 2024 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
TGTan Gemicioglu
Tan Gemicioglu
TVThalia Viranda
Thalia Viranda
YZYiran Zhao
Yiran Zhao
OYOlzhas Yessenbayev
Olzhas Yessenbayev
JAJatin Arora
Jatin Arora
TCTanzeem Choudhury
Tanzeem Choudhury
Workplace stress contributes to poor performance and adverse health outcomes, yet current stress management tools often fall short in the fast-paced modern workforce. Guided slow breathing is a promising intervention for stress and anxiety, with peripheral breathing guides being explored for concurrent task use. However, their need for explicit user engagement underscores the need for more seamless, implicit interventions optimized for workplaces. In this mixed-method, controlled study, we examined the feasibility and effects of BreathePulse, a laptop-mounted device that delivers pulsing airflow to the nostrils as an implicit cue, on stress, anxiety, affect, and workload during two levels of a memory (N-Back) task with 23 participants. We found that BreathePulse, the first airflow-only breathing guide, effectively promoted slow breathing, particularly during the easy memory task. Participants' breathing rates aligned with BreathePulse's guidance across tasks, with the longest maintenance of slow breathing - over 40% of the time - during the easy task. Although BreathePulse increased workload and had little impact on stress, it promoted mindfulness, indicating its potential for stress management in the workplace.

23 December 2024 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
SWSixuan Wu
Sixuan Wu
KSKefan Song
Kefan Song
JCJason Cobb
Jason Cobb
AAAlexander Travis Adams
Alexander Travis Adams
Background: Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. Objective: The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? Methods: To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. Results: In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. Conclusions: In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.

31 December 2024 in JMIR Formative Research
Verified
Journal Article
Open access
YZYiran Zhao
Yiran Zhao
JAJatin Arora
Jatin Arora
YTYujie Tao
Yujie Tao
DMDave B Miller
Dave B Miller
AAAlexander Travis Adams
Alexander Travis Adams
TCTanzeem Choudhury
Tanzeem Choudhury
Background: Digital and wearable intervention systems promise to improve how people manage their behavioral health conditions by making interventions available when the user can best benefit from them. However, existing interventions are obtrusive because they require attention and motivation to engage in, limiting the effectiveness of such systems in demanding contexts, such as when the user experiences alcohol craving. Mindless interventions, developed by the human-computer interaction community, offer an opportunity to intervene unobtrusively. Offset heart rate biofeedback is an iconic type of mindless intervention powered by entrainment and can mitigate the physiological and psychological response to stressors. Objective: This work aimed to characterize the translational effectiveness of offset heart rate biofeedback on cue-elicit alcohol craving among risky drinkers. Methods: We conducted an out-of-lab, between-group, controlled experiment with 26 participants who performed harmful or hazardous drinking. The control group served as negative control and received no intervention, while the experimental group received offset heart rate biofeedback during alcohol exposure and recovery. We elicited alcohol cravings through a series of alcohol cues, including performing mental imagery, viewing alcohol images, and sniffing alcohol. We measured the physiological response to alcohol (ie, heart rate variability), self-reported craving, and self-reported anxiety. We constructed linear mixed-effects models to understand the effect of intervention during alcohol exposure and alcohol recovery after exposure. Following the linear mixed effect model, we conducted pair-wise comparisons for measures between the control and experimental groups. Results: We found that offset heart rate biofeedback significantly reduced the increase in heart rate variability (P=.01 and P=.052) and self-reported craving (P=.04 and P=.02) in response to alcohol cues. Participants’ anxiety was not affected by either the alcohol cues or the offset heart rate biofeedback. Conclusions: Offset heart rate biofeedback has the potential to immediately and unobtrusively mitigate cue-elicit alcohol craving among risky drinkers. The results of this study opened new opportunities for digital and wearable interventions to mitigate alcohol craving, either as wellness apps for risky drinkers or as digital prescriptions and integration with sensing systems for people with alcohol dependency.