Background and Aims: Pulsed field ablation (PFA) has been described as non-thermal, but abundant data exist in oncology applications, and growing data are emerging in cardiology, highlighting that thermal effects are in fact present with PFA. Our objective was to develop a reliable model of the thermal effects arising from PFA of myocardial and esophageal tissue over a range of typical peak voltage operating conditions. Methods: We developed a three-dimensional computer model of the left atrium that can quantify the thermal effects from PFA applications. Energy was applied using a bipolar configuration, and far-field and symmetry boundaries were set as electrically insulating. The model utilizes a monophasic waveform with a pulse width of 100 μs and gap between pulses of 1 s was applied for a total of 50 pulses in a single train, with variations to this easily implemented to accommodate various conditions. Results: Over a range of peak voltage operating conditions (1 kV, 1.5 kV, and 2 kV), minimal temperature rise in the esophagus was seen with 1 kV pulses (corresponding to 215 J input), but with 1.5 kV and 2 kV peak voltages (corresponding to 570 J and 1.23 kJ), temperature elevations reaching 46.3°C and > 62 °C were seen, respectively. These elevations occurred after only a single pulse train of 50 pulses, implying that further elevations in temperature would be seen with subsequent applications. These findings concur with data published in other fields of medicine where pulsed field treatments are utilized. Conclusions: Thermal effects from PFA occur and can be quantified with in-silico modeling. The model described here offers an efficient means of determining temperature effects from PFA over various operating conditions. Energy levels used clinically appear to have the potential to induce collateral thermal injury with repeated applications of pulsed field energy.
24 February 2026 in Journal of Visualized Experiments
Traditional, manual and UV disinfection methods have left gaps in achieving thorough whole-room disinfection for hard-to-reach or shadowed areas, increasing the risk of healthcare-associated infections (HAIs). Effective environmental disinfection is a core component of a comprehensive infection prevention program. Traditional limitations include incomplete disinfection, exposure risk for healthcare personnel, and cost of labor requirements, which warrant the adoption of newer technologies. An automated aerosolized hydrogen peroxide (aHP) dry fogging technology designed to overcome these limitations has recently entered the market, potentially offering a more clinically and economically effective solution. This novel technology provides micron-sized hydrogen peroxide droplets to the entire room, ensuring optimal disinfection of all surfaces. The system also allows integration within data platforms to provide historical data on equipment usage, verification of aHP dosages, room coverage, disinfection times, and locations to provide quality assurance and auditable records. The dispersion of microdroplet aHP via dry fogging offers uniform coverage, providing greater germicidal efficacy for modern healthcare settings. The objective of this protocol is to outline the methods of use of the automated aHP dry fogging system, including the contribution of real-time tracking and auditing capabilities to the management of infection risk. Representative results are then provided demonstrating coverage efficacy as well as the consequent impact on the reduction of transmission, direct cost, and productivity associated with carbapenem-resistant Acinetobacter baumannii (CRAB), a multidrug-resistant organism that has been deemed an "urgent threat" by the CDC. Compared to the lowest per-admission reproduction number of 0.40, where a total of 9.6 patient in-facility transmissions would be expected, application of the dry fogging technology as part of a robust carbapenem-resistant organism (CRO) mitigation strategy demonstrated a statistically significant reduction in the actual rate of transmission compared to the expected rate.
Traditional, manual and UV disinfection methods have left gaps in achieving thorough whole-room disinfection for hard-to-reach or shadowed areas, increasing the risk of healthcare-associated infections (HAIs). Effective environmental disinfection is a core component of a comprehensive infection prevention program. Traditional limitations include incomplete disinfection, exposure risk for healthcare personnel, and cost of labor requirements, which warrant the adoption of newer technologies. An automated aerosolized hydrogen peroxide (aHP) dry fogging technology designed to overcome these limitations has recently entered the market, potentially offering a more clinically and economically effective solution. This novel technology provides micron-sized hydrogen peroxide droplets to the entire room, ensuring optimal disinfection of all surfaces. The system also allows integration within data platforms to provide historical data on equipment usage, verification of aHP dosages, room coverage, disinfection times, and locations to provide quality assurance and auditable records. The dispersion of microdroplet aHP via dry fogging offers uniform coverage, providing greater germicidal efficacy for modern healthcare settings. The objective of this protocol is to outline the methods of use of the automated aHP dry fogging system, including the contribution of real-time tracking and auditing capabilities to the management of infection risk. Representative results are then provided demonstrating coverage efficacy as well as the consequent impact on the reduction of transmission, direct cost, and productivity associated with carbapenem-resistant Acinetobacter baumannii (CRAB), a multidrug-resistant organism that has been deemed an "urgent threat" by the CDC. Compared to the lowest per-admission reproduction number of 0.40, where a total of 9.6 patient in-facility transmissions would be expected, application of the dry fogging technology as part of a robust carbapenem-resistant organism (CRO) mitigation strategy demonstrated a statistically significant reduction in the actual rate of transmission compared to the expected rate.
Background and aims: Epicardial RFA is often required when ventricular tachyarrhythmias originate from epicardial or subepicardial substrates that cannot be effectively ablated endocardially. Our objective was to evaluate the impact of intrapericardial fluid accumulation on the lesion size in the myocardium and the extent of thermal damage to adjacent structures, particularly the lung. Methods: An in silico model of epicardial RFA was developed, featuring an irrigated-tip catheter placed horizontally on the epicardium. A 50 W–30 s RF pulse was simulated. Temperature distributions and resultant thermal lesions in both the myocardium and lung were computed. Results: An increase in pericardial space from 2.5 mm to 4.5 mm resulted in a reduction of myocardial lesion depth by up to 1 mm, while the volume of lung damage decreased from 200 to 300 mm3 to nearly zero, irrespective of myocardial or epicardial fat thickness. Myocardial lesion size was markedly influenced by the thickness of the epicardial fat layer. In the absence of fat and with a narrow pericardial space, lesions reached up to 262 mm3 in volume and 6.1 mm in depth. With 1 mm of fat, lesion volume decreased to below 100 mm3 and depth to 3 mm; with 2 mm, to under 40 mm3 and 2 mm; and with 3 mm, to less than 16 mm3 and 1.2 mm. Lung damage increased moderately with greater fat thickness. Cooling the irrigation fluid from 37 °C to 5 °C reduced lung damage by up to 51%, while myocardial lesion size decreased by only 15%. Conclusions: Intrapericardial fluid accumulation can limit myocardial lesion formation while protecting adjacent structures. Cooling the irrigation fluid may reduce collateral damage without compromising myocardial lesion depth.