Aims: Pulsed field ablation (PFA) is described as non-thermal, but data from oncology and cardiology show thermal effects occur. The specific waveform parameters influencing thermal energy development during PFA are unclear. The aim of this study is to numerically evaluate the thermal effects of PFA on myocardial and oesophageal tissue at various peak voltage conditions. Methods and results: A three-dimensional computer model of the left atrium quantified thermal effects from PFA at peak voltages of 1, 1.5, and 2 kV. Energy was applied using a bipolar configuration with far-field and symmetry boundaries set as electrically insulating. A monophasic waveform with a 100 μs pulse width and a 1 s gap between pulses was applied for a total of 50 pulses, mimicking clinical conditions. Minimal temperature rise in the oesophagus was observed with 1 kV pulses (214.5 J). At 1.5 and 2 kV (570.3 and 1.23 kJ), temperatures reached 46.3°C and >62°C, respectively, after a single pulse train. These findings suggest that repeated applications could lead to even higher temperatures, especially if good tissue contact is obtained. These results align with data from other medical fields using pulsed field treatments. Conclusion: Thermal effects from PFA depend on the total energy deposited, with peak voltage being a significant factor. Current commercially available PFA systems have the potential to induce collateral thermal injury with repeated applications of pulsed field energy. This highlights the need for careful monitoring and adjustment of PFA parameters in clinical settings.
14 September 2022 in International Journal of Hyperthermia
Proactive cooling with a novel cooling device has been shown to reduce endoscopically identified thermal injury during radiofrequency (RF) ablation for the treatment of atrial fibrillation using me...
24 February 2026 in Journal of Visualized Experiments
Traditional, manual and UV disinfection methods have left gaps in achieving thorough whole-room disinfection for hard-to-reach or shadowed areas, increasing the risk of healthcare-associated infections (HAIs). Effective environmental disinfection is a core component of a comprehensive infection prevention program. Traditional limitations include incomplete disinfection, exposure risk for healthcare personnel, and cost of labor requirements, which warrant the adoption of newer technologies. An automated aerosolized hydrogen peroxide (aHP) dry fogging technology designed to overcome these limitations has recently entered the market, potentially offering a more clinically and economically effective solution. This novel technology provides micron-sized hydrogen peroxide droplets to the entire room, ensuring optimal disinfection of all surfaces. The system also allows integration within data platforms to provide historical data on equipment usage, verification of aHP dosages, room coverage, disinfection times, and locations to provide quality assurance and auditable records. The dispersion of microdroplet aHP via dry fogging offers uniform coverage, providing greater germicidal efficacy for modern healthcare settings. The objective of this protocol is to outline the methods of use of the automated aHP dry fogging system, including the contribution of real-time tracking and auditing capabilities to the management of infection risk. Representative results are then provided demonstrating coverage efficacy as well as the consequent impact on the reduction of transmission, direct cost, and productivity associated with carbapenem-resistant Acinetobacter baumannii (CRAB), a multidrug-resistant organism that has been deemed an "urgent threat" by the CDC. Compared to the lowest per-admission reproduction number of 0.40, where a total of 9.6 patient in-facility transmissions would be expected, application of the dry fogging technology as part of a robust carbapenem-resistant organism (CRO) mitigation strategy demonstrated a statistically significant reduction in the actual rate of transmission compared to the expected rate.
Background and Objectives: Laser ablation is increasingly used to treat atrial fibrillation (AF). However, atrioesophageal injury remains a potentially serious complication. While proactive esophageal cooling (PEC) reduces esophageal injury during radiofrequency ablation, the effects of PEC during laser ablation have not previously been determined. We aimed to evaluate the protective effects of PEC during laser ablation of AF by means of a theoretical study based on computer modeling.Methods: Three‐dimensional mathematical models were built for 20 different cases including a fragment of atrial wall (myocardium), epicardial fat (adipose tissue), connective tissue, and esophageal wall. The esophagus was considered with and without PEC. Laser‐tissue interaction was modeled using Beer–Lambert's law, Pennes' Bioheat equation was used to compute the resultant heating, and the Arrhenius equation was used to estimate the fraction of tissue damage (FOD), assuming a threshold of 63% to assess induced necrosis. We modeled laser irradiation power of 8.5 W over 20 s. Thermal simulations extended up to 250 s to account for thermal latency.Results: PEC significantly altered the temperature distribution around the cooling device, resulting in lower temperatures (around 22°C less in the esophagus and 9°C in the atrial wall) compared to the case without PEC. This thermal reduction translated into the absence of transmural lesions in the esophagus. The esophagus was thermally damaged only in the cases without PEC and with a distance equal to or shorter than 3.5 mm between the esophagus and endocardium (inner boundary of the atrial wall). Furthermore, PEC demonstrated minimal impact on the lesion created across the atrial wall, either in terms of maximum temperature or FOD.Conclusions: PEC reduces the potential for esophageal injury without degrading the intended cardiac lesions for a variety of different tissue thicknesses. Thermal latency may influence lesion formation during laser ablation and may play a part in any collateral damage.
Background and aims: Epicardial RFA is often required when ventricular tachyarrhythmias originate from epicardial or subepicardial substrates that cannot be effectively ablated endocardially. Our objective was to evaluate the impact of intrapericardial fluid accumulation on the lesion size in the myocardium and the extent of thermal damage to adjacent structures, particularly the lung. Methods: An in silico model of epicardial RFA was developed, featuring an irrigated-tip catheter placed horizontally on the epicardium. A 50 W–30 s RF pulse was simulated. Temperature distributions and resultant thermal lesions in both the myocardium and lung were computed. Results: An increase in pericardial space from 2.5 mm to 4.5 mm resulted in a reduction of myocardial lesion depth by up to 1 mm, while the volume of lung damage decreased from 200 to 300 mm3 to nearly zero, irrespective of myocardial or epicardial fat thickness. Myocardial lesion size was markedly influenced by the thickness of the epicardial fat layer. In the absence of fat and with a narrow pericardial space, lesions reached up to 262 mm3 in volume and 6.1 mm in depth. With 1 mm of fat, lesion volume decreased to below 100 mm3 and depth to 3 mm; with 2 mm, to under 40 mm3 and 2 mm; and with 3 mm, to less than 16 mm3 and 1.2 mm. Lung damage increased moderately with greater fat thickness. Cooling the irrigation fluid from 37 °C to 5 °C reduced lung damage by up to 51%, while myocardial lesion size decreased by only 15%. Conclusions: Intrapericardial fluid accumulation can limit myocardial lesion formation while protecting adjacent structures. Cooling the irrigation fluid may reduce collateral damage without compromising myocardial lesion depth.
Traditional, manual and UV disinfection methods have left gaps in achieving thorough whole-room disinfection for hard-to-reach or shadowed areas, increasing the risk of healthcare-associated infections (HAIs). Effective environmental disinfection is a core component of a comprehensive infection prevention program. Traditional limitations include incomplete disinfection, exposure risk for healthcare personnel, and cost of labor requirements, which warrant the adoption of newer technologies. An automated aerosolized hydrogen peroxide (aHP) dry fogging technology designed to overcome these limitations has recently entered the market, potentially offering a more clinically and economically effective solution. This novel technology provides micron-sized hydrogen peroxide droplets to the entire room, ensuring optimal disinfection of all surfaces. The system also allows integration within data platforms to provide historical data on equipment usage, verification of aHP dosages, room coverage, disinfection times, and locations to provide quality assurance and auditable records. The dispersion of microdroplet aHP via dry fogging offers uniform coverage, providing greater germicidal efficacy for modern healthcare settings. The objective of this protocol is to outline the methods of use of the automated aHP dry fogging system, including the contribution of real-time tracking and auditing capabilities to the management of infection risk. Representative results are then provided demonstrating coverage efficacy as well as the consequent impact on the reduction of transmission, direct cost, and productivity associated with carbapenem-resistant Acinetobacter baumannii (CRAB), a multidrug-resistant organism that has been deemed an "urgent threat" by the CDC. Compared to the lowest per-admission reproduction number of 0.40, where a total of 9.6 patient in-facility transmissions would be expected, application of the dry fogging technology as part of a robust carbapenem-resistant organism (CRO) mitigation strategy demonstrated a statistically significant reduction in the actual rate of transmission compared to the expected rate.