TULLIO CARLO MARIA ANCORA

Dr. TULLIO CARLO MARIA ANCORA

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Valerio Francesco BarnabeiValerio Francesco Barnabei
Valerio Francesco Barnabei
TATULLIO CARLO MARIA ANCORA
TULLIO CARLO MARIA ANCORA
GDGiovanni Delibra
Giovanni Delibra
Alessandro CorsiniAlessandro Corsini
Alessandro Corsini
FRFranco Rispoli
Franco Rispoli
The increasing deployment of wind energy systems, particularly offshore wind farms, necessitates advanced monitoring and maintenance strategies to ensure optimal performance and minimize downtime. Supervisory Control And Data Acquisition (SCADA) systems have become indispensable tools for monitoring the operational health of wind turbines, generating vast quantities of time series data from various sensors. Anomaly detection techniques applied to this data offer the potential to proactively identify deviations from normal behavior, providing early warning signals of potential component failures. Traditional model-based approaches for fault detection often struggle to capture the complexity and non-linear dynamics of wind turbine systems. This has led to a growing interest in data-driven methods, particularly those leveraging machine learning and deep learning, to address anomaly detection in wind energy applications. This study focuses on the development and application of a semi-supervised, multivariate anomaly detection model for horizontal axis wind turbines. The core of this study lies in Bidirectional Long Short-Term Memory (BI-LSTM) networks, specifically a BI-LSTM autoencoder architecture, to analyze time series data from a SCADA system and automatically detect anomalous behavior that could indicate potential component failures. Moreover, the approach is reinforced by the integration of the Isolation Forest algorithm, which operates in an unsupervised manner to further refine normal behavior by identifying and excluding additional anomalous points in the training set, beyond those already labeled by the data provider. The research utilizes a real-world dataset provided by EDP Renewables, encompassing two years of comprehensive SCADA records collected from a single offshore wind turbine operating in the Gulf of Guinea. Furthermore, the dataset contains the logs of failure events and recorded alarms triggered by the SCADA system across a wide range of subsystems. The paper proposes a multi-modal anomaly detection framework orchestrating an unsupervised module (i.e., decision tree method) with a supervised one (i.e., BI-LSTM AE). The results highlight the efficacy of the BI-LSTM autoencoder in accurately identifying anomalies within the SCADA data that exhibit strong temporal correlation with logged warnings and the actual failure events. The model’s performance is rigorously evaluated using standard machine learning metrics, including precision, recall, F1 Score, and accuracy, all of which demonstrate favorable results. Further analysis is conducted using Cumulative Sum (CUSUM) control charts to gain a deeper understanding of the identified anomalies’ behavior, particularly their persistence and timing leading up to the failures.

31 December 2024 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
Valerio Francesco BarnabeiValerio Francesco Barnabei
Valerio Francesco Barnabei
TATULLIO CARLO MARIA ANCORA
TULLIO CARLO MARIA ANCORA
MCMichela Conti
Michela Conti
Alessio CastorriniAlessio Castorrini
Alessio Castorrini
GDGiovanni Delibra
Giovanni Delibra
FRFranco Rispoli
Franco Rispoli
Floating offshore wind energy will play a key role in the clean energy transition. The number of large-scale wind farm projects is growing in regions like Northern Europe, the East Coast of the U.S., and the Mediterranean Sea. Offshore wind farms face fewer layout constraints, as they can be situated in vast, open sea areas. Turbines are often arranged in simple layouts, such as grid patterns, but this can cause significant annual energy production (AEP) losses due to wake–rotor interaction. Increasing spacing can mitigate this effect, but it may not always be feasible due to marine space limitations or higher costs for cabling and maintenance. This paper introduces a multi-objective wind farm optimization framework using a non sorted genetic algorithm (NSGA II) to minimize costs and maximize AEP. The method is applied to two case studies in the Mediterranean Sea, assuming 15 MW wind turbines. Case A is located off the coast of Civitavecchia, and case B in the Gulf of Squillace. AEP evaluation is performed with the open-source library FLOw Redirection and Induction in Steady-State (floris), while optimization is done using pymoo. In case A, the layout characterized by the lowest levelized cost of energy (LCOE) features 16 turbines, achieving an AEP of 709 GWh, an LCOE of 112.06 €/MWh, and wake losses of 2.6%. Meanwhile, in case B, the layout with the lowest LCOE consists of 19 turbines, achieving an AEP of 1140 GWh, an LCOE of 80.82 €/MWh, and wake losses of 4%.

1 May 2026 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
TATULLIO CARLO MARIA ANCORA
TULLIO CARLO MARIA ANCORA
VBV F Barnabei
V F Barnabei
ACA Corsini
A Corsini
LGL Gambadori
L Gambadori
AMA E Milani
A E Milani
SWS Watson
S Watson
This work presents a physics-informed normal behaviour modelling approach for wind turbine gearbox condition monitoring based on SCADA data. The methodology relies on a Physics-Informed Autoencoder, in which a thermo-dynamic model of the gearbox is embedded into the training loss to incorporate domain knowledge into the learning process. SCADA signals related to gearbox operation are used to train the model under healthy conditions, allowing the characterisation of normal gearbox behaviour. Anomaly detection is performed by monitoring the reconstruction error and applying a CUSUM-based detection scheme to assess the persistence of deviations. The approach is validated using a public dataset provided by EDP Renewables, comprising SCADA data from four wind turbines. Results show that the proposed framework is capable of detecting a documented “Gearbox pump damaged” fault event five days in advance, without generating false alarms during normal operation.

6 November 2026 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
GBGianmarco Bianchi
Gianmarco Bianchi
FRFederico Roma
Federico Roma
TATULLIO CARLO MARIA ANCORA
TULLIO CARLO MARIA ANCORA
Valerio Francesco BarnabeiValerio Francesco Barnabei
Valerio Francesco Barnabei
Condition-based maintenance of wind turbines is increasingly relying on Supervisory Control and Data Acquisition (SCADA) systems as a cost-effective alternative to dedicated condition monitoring hardware. However, the high dimensionality, non-stationarity, and complex inter-variable dependencies of SCADA data make early anomaly detection particularly challenging. This work proposes an anomaly detection framework for wind turbines based on a multichannel image encoding of SCADA data and a Convolutional Autoencoder (CAE) trained as a Normal Behaviour Model. The proposed methodology transforms multivariate SCADA time windows into two-channel image-like tensors. The first channel is based on Spearman rank correlation, allowing the model to capture changes in the dependency structure among variables, while the second channel is based on pairwise Mahalanobis distance, enabling the detection of drifts and deviations in the statistical magnitude of operating conditions. These multichannel representations are then processed by a CAE designed to reconstruct healthy operating patterns and identify anomalies through reconstruction errors. To improve interpretability, the framework also includes a fault localization attempt based on the spatial analysis of reconstruction residuals. By comparing anomalous and healthy residual matrices, the method highlights the SCADA variables that contribute most to the detected anomaly, providing preliminary localization support in addition to turbine-level anomaly detection. The approach is validated on a real-world open-access SCADA dataset comprising four wind turbines and associated fault event logs, enabling an event-based evaluation of anomaly detection performance. The proposed method achieved an overall Precision of 0.67, Recall of 0.89, and F1-score of 0.76.