Chiara Martina

Mrs. Chiara Martina

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
Chiara MartinaChiara Martina
Chiara Martina
BSBortolino Saggin
Bortolino Saggin
EZEmiliano Zampetti
Emiliano Zampetti
This study focuses on piezoelectric quartz crystal microbalances (QCMs), widely used in space and military instrumentation, as fundamental components in highly sensitive mass detection devices. In this research, a proper setup was developed to investigate the relationship between clamping preload and crystal resonance, with particular attention to the effects of concentrated loads. The latter ones, not properly addressed in the literature, come from the need to safely clamp QCMs in critical environments, like those experienced during the launch of rockets or payloads. Thus, the study investigates the behaviour of piezoelectric quartz crystals (AT-cut, 10 MHz) with gold electrodes, using a QCMs’ three-pinned mounting system. Measurements showed that the effect of the preload on the frequency variation resulted in a repeatable increase in the crystals’ resonance, increasing the loading, up to three ppm more than the unloaded quartz crystal oscillating frequency.

1 April 2026 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
Chiara MartinaChiara Martina
Chiara Martina
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
BSBortolino Saggin
Bortolino Saggin
EZEmiliano Zampetti
Emiliano Zampetti
EPErnesto Palomba
Ernesto Palomba

Verified
Journal Article
Open access
PDF file
Chiara MartinaChiara Martina
Chiara Martina
AAAndrea Appiani
Andrea Appiani
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
Background: Research on vibrations induced by running has gained significant attention due to its implications for athletes’ performance, injury prevention, and overall well-being. Distance running exposes the body to repetitive impulsive forces, causing significant vibrations to travel through physiological systems and biomechanical structures. These vibrations increase fatigue and the risk of injury. Although it has gained importance, research on induced vibration during running and wearable equipment for monitoring is scarce. This study aims to evaluate the performance of a measurement system for monitoring the acceleration levels of induced vibrations during long-distance running, exploring the capability of non-invasive wearable devices to characterise vibration transmissibility and exposure. Moreover, a preliminary quantitative assessment of induced vibration levels for an indoor testing scenario is given. Methods: Metrological characterisation of Xsens Motion Trackers Awinda (MTw), off-the-shelf inertial magnetic motion trackers, was performed by measuring the sensors’ frequency bandwidth in a controlled environment, providing logarithmic sweep sine excitations at different levels (2 g, 5 g, 7 g, where g is meant to be the gravitational acceleration). A testing protocol for indoor testing was derived from the literature, allowing characterisation of the sensors’ behaviour in terms of vibration transmissibility and exposure detection in the intended application. Time domain and frequency domain analyses were conducted by following the ISO 2631 standard guideline for vibration exposure assessment, and measurement uncertainty was defined, either for the dynamic correction of the sensors’ frequency behaviour or for the computed time and frequency domain metrics. In this framework, a treadmill-based test was conducted. The aim was to evaluate the Xsens sensors’ performance in measuring vibration dose exposure and transmissibility. Three MTws were placed on the subject’s right tibia, back, and forehead using elastic bands. A 25-year-old female amateur runner completed a series of tests consisting of walking for 1 min at 3.5 km/h (instrumentation setup), followed by running at two speeds (8 km/h and 11 km/h) for 2–4 min per trial, with 5 min rest periods between tests. Conclusions: The tested measurement system showed promising results due to its capability to assess vibration exposure during sports activities, but dynamic correction was found to be mandatory for accurate vibration level assessment. The main outcome of this study is a method for characterising the accelerometers embedded in the proposed devices, along with an analysis strategy for future testing campaigns. Thanks to the portability of IMUs (inertial measurement units), this approach enables the evaluation of induced vibrations during in-field running measurements.

28 August 2026 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
Chiara MartinaChiara Martina
Chiara Martina
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
BSBortolino Saggin
Bortolino Saggin
EZEmiliano Zampetti
Emiliano Zampetti
EPErnesto Palomba
Ernesto Palomba

27 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Chiara MartinaChiara Martina
Chiara Martina
Abdelrahman Mohamed Ragab M. AhmedAbdelrahman Mohamed Ragab M. Ahmed
Abdelrahman Mohamed Ragab M. Ahmed
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
The research focuses on the dynamic calibration of off-the-shelf inertial measurement unit (IMU) triaxial accelerometers, sensors generally used for kinematic analyses in sport and biomedical engineering. The assessment of Xsens Movella DOT sensors' performance, reliability, and limitations is presented, providing a metrological basis for their application in wearable monitoring systems. The metrological characterisation was performed to quantify the sensors’ dynamic response, their bandwidth, and measurement repeatability and reproducibility within the range of interest. Three units from the same batch were tested along three orthogonal axes under controlled excitation conditions, using a laser Doppler vibrometer as reference. The experimental protocol included harmonic excitations in the 10–45 Hz range, harmonic excitation up to 130 Hz to quantify limitations and potential errors of the sensors when measuring signals out of the nominal bandwidth, and random excitation, limited in the frequency range up to about 40 Hz, to validate their applicability in a generic dynamic environment. Thus, the acquired signals were analysed in both the time and frequency domains: in particular, the Frequency Response Function (FRF) between the IMU accelerometers and the reference system was measured, along all three measurement directions, and the corresponding Power Spectral Densities (PSDs) were computed. A numerical optimisation procedure was then applied to model the acquired FRF, providing an estimation of the FRF complex function, allowing for correction in general dynamic applications. One major result was that dynamic compensation is mandatory within the nominal bandwidth, given the attenuation of the measured amplitude of about 25% at the maximum frequency of the bandwidth; moreover, aliasing error occurs if the excitation frequency is above the Nyquist frequency, introducing frequency-dependent errors and misleading results. Thus, the proposed methodology and correction model, together with the highlighted instrumental effects, allow for accurate acceleration measurements by using the tested Xsens Movella DOT sensors in an induced and transmitted vibration scenario, although the defined methodology can be more generally extended to similar devices and instruments, aiming for proper dynamic characterisation.

9 July 2025
Verified
Conference Paper
Open access
EPErnesto Palomba
Ernesto Palomba
ALAndrea Longobardo
Andrea Longobardo
FDFabrizio Dirri
Fabrizio Dirri
CGChiara Gisellu
Chiara Gisellu
ENEnrico Nardi
Enrico Nardi
Maria PEDONEMaria PEDONE
Maria PEDONE
The CNSA (China National Space Administration) Tianwen 2 mission [1] will study and sample the Kamo’oalewa near-Earth asteroid and then rendezvous with the 311/PANSTARRS Main Belt Comet (MBC). The mission is scheduled to launch in May 2025, with arrival at Kamo’oalewa in 2026. Then, the spacecraft will land on the asteroid and collect samples of its surface, and deliver them to Earth around 2027. The main spacecraft will then head for 311P/PANSTARRS, which has asteroid-like orbital characteristics but also features comet-like activity. The mission aims at providing insight into the composition and evolution of near-Earth objects and understand the distribution of water and organic molecules and the history of the early Solar System.The mission includes several instruments, such as multispectral cameras, thermal emission spectrometer, imaging spectrometer, mass spectrometer, a magnetometer and a dust analyser. The dust analyser is a suit of different sensors, including the DIANA (Dust In situ ANAlyser) instrument.DIANA is based on Quartz Crystal Microbalance (QCM) devices, aiming at detecting dust and volatiles content, as well as assessing contamination on board the spacecraft. This kind of sensors converts mass changes into fundamental resonance frequency variations, according to Sauerbrey equation [2]. DIANA can be heated thanks to the crystals built-in heaters [3] or cooled by a Thermo-Electric Cooler (TEC). Thanks to its customized design [4], DIANA is capable of performing Thermo-Gravimetric Analysis (TGA), a technique widely used to study mas variation processes as a function of temperature, in order to measure the abundance of volatile compounds of astrobiological interests (e.g. water, organics) in the cometary dust and reveal the occurrence of contaminants that could condense on the crystal.DIANA payload is composed by: 1) a sensor head (DIANA SH1), that works at low temperature (i.e. 225-400K), to measure the dust flux and the amount of physically absorbed water, as well as contamination assessment during Tianwen2 cruise phase; 2) a sensor head (DIANA SH2), that works at higher temperatures (up to 500K), to measure the dust flux and amount of organic components; 3) a Main Electronics Unit (MEU), to read SH1 and SH2 frequencies and temperatures and set the heating ramp rates for TGA.The technical characteristics of DIANA are shown in Table 1, while the two sensor heads are shown in Figure 1.Table 1. DIANA technical characteristics.Figure 1. DIANA sensor heads: SH1 on the left and SH2 on the right.DIANA was developed by an Italian Consortium led by INAF-IAPS (Istituto Nazionale di AstroFisica-Istituto di Astrofisica e Planetologia Spaziali), in collaboration with CNR-IIA (Consiglio Nazionale delle Ricerche-Istituto sull’Inquinamento Atmosferico) and Politecnico di Milano-MetroSpace Lab. The MEU was developed in collaboration with Shanghai Institute of Technical Physics (SITP).Acknowledgments: DIANA development activities are funded by the Italian Space Agency through the ASI-INAF Agreement 2022-27-HH.0.References:[1] Zhang, X. et al. (2019), LPSC abstracts, 1045[2] Sauerbrey, G. (1959), Z. Phys, 155, 206–222[3] Palomba, E. et al. (2016), OLEB, 46, 273-281[4] Martina, C. et al. (2024), IAC abstracts, 8785