Andrea Appiani

Dr. Andrea Appiani

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2025 in Designs
Verified
Journal Article
Open access
PDF file
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
Abdelrahman Mohamed Ragab M. AhmedAbdelrahman Mohamed Ragab M. Ahmed
Abdelrahman Mohamed Ragab M. Ahmed
AAAndrea Appiani
Andrea Appiani
BSBortolino Saggin
Bortolino Saggin
CPCarmen Porto
Carmen Porto
Francesca EspositoFrancesca Esposito
Francesca Esposito
This work presents a comparative design of the sensing elements for the Lunar Dust GRID System (LD GRIDS), a dust analyser conceived to measure charged particles on future lunar missions. LD GRIDS replaces traditional electrodes with continuous conductive grids, i.e., the sensing elements of the instrument, which are able to collect induced charge when charged particles pass through them. The investigation focuses on evaluating the influence of various grid geometrical parameters (size, thickness, and patterns) on the sensor’s performance, either from an electrical or a mechanical perspective. All simulations were carried out using off-the-shelf numerical modelling software, where electrostatic simulation (i.e., induction performance), modal analysis, and quasi-static structural responses under a high acceleration quasi-static load were examined. The results indicate that while grids with round patterns tend to produce a higher induced charge, they also experience higher localised stresses compared to square pattern ones. Moreover, grid size does not significantly affect the instrument sensitivity, whereas increasing the grid thickness significantly reduces peak stresses, with only minor effects on electrostatic performance. Overall, the findings provided valuable insights for optimising the LD GRIDS design, aimed at balancing either electrostatic sensitivity or mechanical resistance, facing the harsh lunar environment.

Verified
Journal Article
Open access
PDF file
Chiara MartinaChiara Martina
Chiara Martina
AAAndrea Appiani
Andrea Appiani
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
Background: Research on vibrations induced by running has gained significant attention due to its implications for athletes’ performance, injury prevention, and overall well-being. Distance running exposes the body to repetitive impulsive forces, causing significant vibrations to travel through physiological systems and biomechanical structures. These vibrations increase fatigue and the risk of injury. Although it has gained importance, research on induced vibration during running and wearable equipment for monitoring is scarce. This study aims to evaluate the performance of a measurement system for monitoring the acceleration levels of induced vibrations during long-distance running, exploring the capability of non-invasive wearable devices to characterise vibration transmissibility and exposure. Moreover, a preliminary quantitative assessment of induced vibration levels for an indoor testing scenario is given. Methods: Metrological characterisation of Xsens Motion Trackers Awinda (MTw), off-the-shelf inertial magnetic motion trackers, was performed by measuring the sensors’ frequency bandwidth in a controlled environment, providing logarithmic sweep sine excitations at different levels (2 g, 5 g, 7 g, where g is meant to be the gravitational acceleration). A testing protocol for indoor testing was derived from the literature, allowing characterisation of the sensors’ behaviour in terms of vibration transmissibility and exposure detection in the intended application. Time domain and frequency domain analyses were conducted by following the ISO 2631 standard guideline for vibration exposure assessment, and measurement uncertainty was defined, either for the dynamic correction of the sensors’ frequency behaviour or for the computed time and frequency domain metrics. In this framework, a treadmill-based test was conducted. The aim was to evaluate the Xsens sensors’ performance in measuring vibration dose exposure and transmissibility. Three MTws were placed on the subject’s right tibia, back, and forehead using elastic bands. A 25-year-old female amateur runner completed a series of tests consisting of walking for 1 min at 3.5 km/h (instrumentation setup), followed by running at two speeds (8 km/h and 11 km/h) for 2–4 min per trial, with 5 min rest periods between tests. Conclusions: The tested measurement system showed promising results due to its capability to assess vibration exposure during sports activities, but dynamic correction was found to be mandatory for accurate vibration level assessment. The main outcome of this study is a method for characterising the accelerometers embedded in the proposed devices, along with an analysis strategy for future testing campaigns. Thanks to the portability of IMUs (inertial measurement units), this approach enables the evaluation of induced vibrations during in-field running measurements.

25 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
AAAndrea Appiani
Andrea Appiani
Diego ScaccabarozziDiego Scaccabarozzi
Diego Scaccabarozzi
BSBortolino Saggin
Bortolino Saggin
This work presents an original implementation of the digital sampling pipeline for spaceborne Fourier Transform Spectrometers (FTSs). The implementation aims at improving the robustness of the spectrometer to harsh environmental conditions, including mechanical vibrations and a wide operational temperature range, avoiding the use of dedicated electronic hardware for the interferometer mirrors’ speed control and interferogram sampling. The FTS configuration is based on the constant time step sampling of the interferometer using a standard ADC (Analogue to Digital Converter), along with two metrology laser channels. The development tool is a MATLAB-based simulator developed to emulate the FTS and, in particular, the generation and acquisition of interferograms, incorporating harmonic vibrations and detector noise. The simulator was exploited to compare state-of-the-art techniques and newly implemented variants. An improvement of the arccosine method is first proposed, revising the normalisation process to exploit the full set of recorded data without discarding critical points. Subsequently, methods using two reference channels have been developed and evaluated. Two implementations are considered: two references at the same wavelength with an optimised phase shift (i.e., π/2) and two references at different wavelengths. Different data fusion strategies are compared in terms of spectral uncertainty, varying types of simulated disturbances and noise amplitudes. Results show that the optimal combination of two same-wavelength references consistently outperforms any other configuration, yielding lower average spectral errors and more stable performance over the frequency range and for a lower SNR of reference channels. Conversely, dual-wavelength strategies exhibit reduced accuracy, though they offer flexibility when fixed phase shifts cannot be maintained. The optimal combination of two same-wavelength reference channels, phase-shifted, is a promising configuration for spaceborne FTSs, so the development and test of an instrument breadboard is envisaged as the consequent development of this work.