Amauri Amorin Assef

Dr. Amauri Amorin Assef

Department of Electrical Engineering, Federal University of Technology – Paraná, Curitiba, Paraná, Brazil
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Leonardo Göbel FernandesLeonardo Göbel Fernandes
Leonardo Göbel Fernandes
Alceu André BadinAlceu André Badin
Alceu André Badin
DCDaniel Flores Cortez
Daniel Flores Cortez
RGRoger Gules
Roger Gules
EREduardo Félix Ribeiro Romaneli
Eduardo Félix Ribeiro Romaneli
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
A single-phase transformerless online uninterruptible power supply (UPS) is proposed in this paper. This UPS is based on the new half-bridge doubler-boost with switchedcapacitor operation. It is capable of operating with AC and DC input sources. The proposed converter provides a high power factor and improves power efficiency for line voltage applications. The switched capacitor concept allows a natural balance of the DC bus capacitor voltages, both in the AC-DC mode and in the DC-DC mode. It presents a common point between line voltage source, load, and batteries. This characteristic makes it possible to eliminate the common mode current, reducing problems with EMI and allowing the use of a simple bypass system. The feasibility of the proposed UPS is verified by experimental results from a 2.5 kW prototype with an efficiency of up to 94.9% and unity power factor.

1 January 2013 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
JMJoaquim Miguel Maia
Joaquim Miguel Maia
FFábio Schneider
Fábio Schneider
VBVera Lsn Button
Vera Lsn Button
ECEduardo T Costa
Eduardo T Costa
In ultrasound imaging systems, the digital transmit beamformer is a critical module that generates accurate control over several transmission parameters. However, such transmit front-end module is not typically accessible to ultrasound researchers. To overcome this difficulty, we have been developing a compact and fully programmable digital transmit system using the pulse-width modulation (PWM) technique for generating simultaneous arbitrary waveforms, specifically designed for research purposes. In this paper we present a reconfigurable arbitrary waveform generator (RAWG) for ultrasound research applications that exploits a high frequency PWM scheme implemented in a low-cost FPGA, taking advantage of its flexibility and parallel processing capability for independent controlling of multiple transmission parameters. The 8-channel platform consists of a FPGA-based development board including an USB 2.0 interface and an arbitrary waveform generator board with eight MD2130 beamformer source drivers for individual control of waveform, amplitude apodization, phase angle and time delay trigger. To evaluate the efficiency of our system, we used equivalent RC loads (1 kΩ and 220 pF) to produce arbitrary excitation waveforms with the Gaussian and Tukey profiles. The PWM carrier frequency was set at 160 MHz featuring high resolution while keeping a minimum time delay of 3.125 ns between pulses to enable the acoustic beam to be focused and/or steered electronically. Preliminary experimental results show that the RAWG can produce complex arbitrary pulses with amplitude over 100 Vpp and central frequency up to 20 MHz with satisfactory linearity of the amplitude apodization, as well as focusing phase adjustment capability with angular resolution of 7.5°. The initial results of this study showed that the proposed research system is suitable for generating simultaneous arbitrary waveforms, providing extensive user control with direct digital access to the various transmission parameters needed to explore alternative ultrasound transmission techniques.

28 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NJNivaldo Theodoro Schiefler Jr.
Nivaldo Theodoro Schiefler Jr.
JMJoaquim Miguel Maia
Joaquim Miguel Maia
FFábio Schneider
Fábio Schneider
AZAcácio José Zimbico
Acácio José Zimbico
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
ECEduardo T. Costa
Eduardo T. Costa
Ultrasonic imaging is one of the most important techniques to help medical diagnosis. However, obtaining high quality images requires the acquisition, processing, and storage of a large amount of data. In this work, we evaluated a new ultrasound imaging technique based on plane wave and sparse arrays to increase the scan rate and reduce the amount of data amount to be stored. The performance of the proposed method was tested using simulated echo data (from Field II) and phantom data acquired using a Verasonics system equipped with a L11-4v linear array transducer. The tests were done using 128 elements for transmission and 128, 65, 44, and 23 elements sparsely distributed for reception. The simulated data were compared with images obtained with the Delay and Sum (DAS) method and the experimental data were compared with those acquired from Verasonics. The obtained results using the Full Width at Half Maximum (FWHM) criteria at −6 dB showed that the images generated by the proposed method were similar in terms of resolutions (axial and lateral) and contrast to the simulated and the Verasonics commercial ones, indicating that the sparse reception proposed method is suitable for ultrasound imaging.

1 September 2015 in Research on Biomedical Engineering
Verified
Journal Article
Open access
PDF file
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
JMJoaquim Miguel Maia
Joaquim Miguel Maia
ECEduardo Tavares Costa
Eduardo Tavares Costa
IntroductionIn this paper, we present the initial results of a fully programmable 128-channel FPGA and PC-based system that has been developed for medical ultrasound (US) imaging research in our University laboratory (Federal University of Technology - Paraná, Brazil).MethodsIn order to demonstrate the feasibility of the US research system, two applications involving unfocused plane wave transmission and conventional B-mode beamforming were evaluated using a commercial tissue-mimicking phantom and a 3.2 MHz 128-element convex array transducer.ResultsTesting results show that the hardware platform is able to synthesize arbitrary pulses up to 100 Vpp with second order harmonic distortion below 80 dB. For the first application, a 41-tap digital FIR bandpass filter was applied to the acquired RF echoes, sampled at 40 MHz with 12-bit resolution, to improve the noise suppression. In the second application, after offline apodization weighting, filtering, delay-and-sum processing, envelope detection, log compression and scan conversion, the reconstructed B-mode image is displayed over a 50 dB range.DiscussionThe presented results indicate that the open US imaging system can be used to support different ultrasonic transmission and reception strategies, which typically cannot be implemented in conventional data flow architectures that are mainly based on hardware

27 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JOJonathan de Oliveira
Jonathan de Oliveira
MSMauren Abreu de Souza
Mauren Abreu de Souza
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
JMJoaquim Miguel Maia
Joaquim Miguel Maia
The study of muscle contractions generated by the muscle-tendon unit (MTU) plays a critical role in medical diagnoses, monitoring, rehabilitation, and functional assessments, including the potential for movement prediction modeling used for prosthetic control. Over the last decade, the use of combined traditional techniques to quantify information about the muscle condition that is correlated to neuromuscular electrical activation and the generation of muscle force and vibration has grown. The purpose of this review is to guide the reader to relevant works in different applications of ultrasound imaging in combination with other techniques for the characterization of biological signals. Several research groups have been using multi-sensing systems to carry out specific studies in the health area. We can divide these studies into two categories: human–machine interface (HMI), in which sensors are used to capture critical information to control computerized prostheses and/or robotic actuators, and physiological study, where sensors are used to investigate a hypothesis and/or a clinical diagnosis. In addition, the relevance, challenges, and expectations for future work are discussed.

15 January 2018 in Research on Biomedical Engineering
Verified
Journal Article
Open access
PDF file
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
BFBreno Mendes Ferreira
Breno Mendes Ferreira
JMJoaquim Miguel Maia
Joaquim Miguel Maia
ECEduardo Tavares Costa
Eduardo Tavares Costa
Keywords Ultrasound; Envelope detection; Hilbert transform; FPGA; Simulink