The relative motion between residual limb and prosthetic socket could be a relevant factor in quantifying socket fit. The measurement of these movements, particularly in dynamic gait situations, poses a challenging task. This paper presents the realization of a measurement concept based on multiple optical 2D-motion sensors. The performance of the system was evaluated on a test rig considering accuracy and precision as well as accomplished measurement frequency and reliability of the system. Additionally, results of a pilot study measuring the relative motion between residual limb and prosthetic socket at seven specific locations of one individual with transtibial amputation during straight level walking are presented. The sensor functionality of the array was confirmed and the test rig experiments were comparable to the previously tested functional model ( e r r rel = 0.52 ± 1.87 %). With a sampling frequency of 1.3 kHz to be distributed among the number of sensor units, the developed system is suitable for investigating the relative movement between residual limb and prosthetic socket in dynamic gait situations. Results of the pilot study show the majority of relative motion occurring during the second half of the gait cycle. The measured relative motions show the residual limb sinking deeper into the socket, extending in the Sagittal plane and rotating internally in the Transverse plane during stance phase. Data captured during swing phase indicate a lower limb extension in the Sagittal plane as well as an external rotation in the Transverse plane.

6 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
VNVeronika Noll
Veronika Noll
Stephan RinderknechtStephan Rinderknecht
Stephan Rinderknecht
PBPhilipp Beckerle
Philipp Beckerle
A sensor system for measuring the relative movement between prosthetic socket and residual limb based on a 2D-motion sensor is introduced and thoroughly tested experimentally. The quantitative analysis of test rig evaluation is used to identify advantageous sensor settings and liner configurations. Considering these favorable settings, sensor functionality is quantified to errrel=0.52±1.78%. Advancing to convex measurement surfaces, the sensor shows absolute errors of errabs≤1 mm in an observable measurement scenario. The feasibility of measuring gait-induced relative movement with the proposed 2D-motion sensor is shown via a biomechanical plausibility study. Overall, the findings suggest that the proposed sensor system is suitable for investigating the relative movement between residual limb and prosthetic socket in dynamic gait situations.

1 March 2017 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
VNVeronika Noll
Veronika Noll
NENiclas Eschner
Niclas Eschner
CSChristian Schumacher
Christian Schumacher
PBPhilipp Beckerle
Philipp Beckerle
SRStephan Rinderknecht
Stephan Rinderknecht
The amputee’s well-being and mobility are distinclty related to socket fit and resulting biomechanical interaction between residual limb and prosthetic socket. Understanding the dynamic interactions at the interface may lead to new socket standards. This paper introduces a physically-motivated reduced model of the interface, describing the dynamic interactions between residual limb and prosthetic socket. The model allows to investigate the sensitivity to changes of specific parameters in an isolated matter. A simulation study shows how stress distribution changes if friction coefficients are varied which might advance liner design.