Muhammad Zia ur Rehman

Dr. Muhammad Zia ur Rehman

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MRMuhammad Zia ur Rehman
Muhammad Zia ur Rehman
AWAsim Waris
Asim Waris
SGSyed Gilani
Syed Gilani
MJMads Jochumsen
Mads Jochumsen
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
EKErnest N. Kamavuako
Ernest N. Kamavuako
Pattern recognition of electromyography (EMG) signals can potentially improve the performance of myoelectric control for upper limb prostheses with respect to current clinical approaches based on direct control. However, the choice of features for classification is challenging and impacts long-term performance. Here, we propose the use of EMG raw signals as direct inputs to deep networks with intrinsic feature extraction capabilities recorded over multiple days. Seven able-bodied subjects performed six active motions (plus rest), and EMG signals were recorded for 15 consecutive days with two sessions per day using the MYO armband (MYB, a wearable EMG sensor). The classification was performed by a convolutional neural network (CNN) with raw bipolar EMG samples as the inputs, and the performance was compared with linear discriminant analysis (LDA) and stacked sparse autoencoders with features (SSAE-f) and raw samples (SSAE-r) as inputs. CNN outperformed (lower classification error) both LDA and SSAE-r in the within-session, between sessions on same day, between the pair of days, and leave-out one-day evaluation (p < 0.001) analyses. However, no significant difference was found between CNN and SSAE-f. These results demonstrated that CNN significantly improved performance and increased robustness over time compared with standard LDA with associated handcrafted features. This data-driven features extraction approach may overcome the problem of the feature calibration and selection in myoelectric control.

1 October 2016 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MJMuzzamil Javaid
Muzzamil Javaid
MJMoazzam Javid
Moazzam Javid
MRMuhammad Zia ur Rehman
Muhammad Zia ur Rehman
SSSyed Irtiza Ali Shah
Syed Irtiza Ali Shah

11 July 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMuhammad Zia ur Rehman
Muhammad Zia ur Rehman
SGSyed Gilani
Syed Gilani
AWAsim Waris
Asim Waris
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
GSGreg Slabaugh
Greg Slabaugh
EKErnest N. Kamavuako
Ernest N. Kamavuako
Advances in myoelectric interfaces have increased the use of wearable prosthetics including robotic arms. Although promising results have been achieved with pattern recognition-based control schemes, control robustness requires improvement to increase user acceptance of prosthetic hands. The aim of this study was to quantify the performance of stacked sparse autoencoders (SSAE), an emerging deep learning technique used to improve myoelectric control and to compare multiday surface electromyography (sEMG) and intramuscular (iEMG) recordings. Ten able-bodied and six amputee subjects with average ages of 24.5 and 34.5 years, respectively, were evaluated using offline classification error as the performance matric. Surface and intramuscular EMG were concurrently recorded while each subject performed 11 hand motions. Performance of SSAE was compared with that of linear discriminant analysis (LDA) classifier. Within-day analysis showed that SSAE (1.38 ± 1.38%) outperformed LDA (8.09 ± 4.53%) using both the sEMG and iEMG data from both able-bodied and amputee subjects (p < 0.001). In the between-day analysis, SSAE outperformed LDA (7.19 ± 9.55% vs. 22.25 ± 11.09%) using both sEMG and iEMG data from both able-bodied and amputee subjects. No significant difference in performance was observed for within-day and pairs of days with eight-fold validation when using iEMG and sEMG with SSAE, whereas sEMG outperformed iEMG (p < 0.001) in between-day analysis both with two-fold and seven-fold validation schemes. The results obtained in this study imply that SSAE can significantly improve the performance of pattern recognition-based myoelectric control scheme and has the strength to extract deep information hidden in the EMG data.

1 March 2018 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
MRMuhammad Zia ur Rehman
Muhammad Zia ur Rehman
MJMuzzamil Javaid
Muzzamil Javaid
SSSyed Irtiza Ali Shah
Syed Irtiza Ali Shah
SGSyed Gilani
Syed Gilani
Mohsin JamilMohsin Jamil
Mohsin Jamil
SBShahid Ikramullah Butt
Shahid Ikramullah Butt

20 May 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
ASAhsan Shahzad
Ahsan Shahzad
AMAbid Mushtaq
Abid Mushtaq
ASAbdul Quddoos Sabeeh
Abdul Quddoos Sabeeh
YGYazeed Ghadi
Yazeed Ghadi
Zohaib MushtaqZohaib Mushtaq
Zohaib Mushtaq
FJFaisal Jamil
Faisal Jamil
Fibroids of the uterus are a common benign tumor affecting women of childbearing age. Uterine fibroids (UF) can be effectively treated with earlier identification and diagnosis. Its automated diagnosis from medical images is an area where deep learning (DL)-based algorithms have demonstrated promising results. In this research, we evaluated state-of-the-art DL architectures VGG16, ResNet50, InceptionV3, and our proposed innovative dual-path deep convolutional neural network (DPCNN) architecture for UF detection tasks. Using preprocessing methods including scaling, normalization, and data augmentation, an ultrasound image dataset from Kaggle is prepared for use. After the images are used to train and validate the DL models, the model performance is evaluated using different measures. When compared to existing DL models, our suggested DPCNN architecture achieved the highest accuracy of 99.8 percent. Findings show that pre-trained deep-learning model performance for UF diagnosis from medical images may significantly improve with the application of fine-tuning strategies. In particular, the InceptionV3 model achieved 90% accuracy, with the ResNet50 model achieving 89% accuracy. It should be noted that the VGG16 model was found to have a lower accuracy level of 85%. Our findings show that DL-based methods can be effectively utilized to facilitate automated UF detection from medical images. Further research in this area holds great potential and could lead to the creation of cutting-edge computer-aided diagnosis systems. To further advance the state-of-the-art in medical imaging analysis, the DL community is invited to investigate these lines of research. Although our proposed innovative DPCNN architecture performed best, fine-tuned versions of pre-trained models like InceptionV3 and ResNet50 also delivered strong results. This work lays the foundation for future studies and has the potential to enhance the precision and suitability with which UF is detected.

27 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSaman Khalil
Saman Khalil
UNUroosa Nawaz
Uroosa Nawaz
ZUZubariah
Zubariah
Zohaib MushtaqZohaib Mushtaq
Zohaib Mushtaq
Saad ArifSaad Arif
Saad Arif
KAKhalid Alhussaini
Khalid Alhussaini
Breast cancer ranks among the leading causes of death for women globally, making it imperative to swiftly and precisely detect the condition to ensure timely treatment and enhanced chances of recovery. This study focuses on transfer learning with 3D U-Net models to classify ductal carcinoma, the most frequent subtype of breast cancer, in histopathology imaging. In this research work, a dataset of 162 microscopic images of breast cancer specimens is utilized for breast histopathology analysis. Preprocessing the original image data includes shrinking the images, standardizing the intensities, and extracting patches of size 50 × 50 pixels. The retrieved patches were employed to construct a basic 3D U-Net model and a refined 3D U-Net model that had been previously trained on an extensive medical image segmentation dataset. The findings revealed that the fine-tuned 3D U-Net model (97%) outperformed the simple 3D U-Net model (87%) in identifying ductal cancer in breast histopathology imaging. The fine-tuned model exhibited a smaller loss (0.003) on the testing data (0.041) in comparison to the simple model. The disparity in the training and testing accuracy reveals that the fine-tuned model may have overfitted to the training data indicating that there is room for improvement. To progress in computer-aided diagnosis, the research study also adopted various data augmentation methodologies. The experimental approach that was put forward achieved state-of-the-art performance, surpassing the benchmark techniques used in previous studies in the same field, and exhibiting greater accuracy. The presented scheme has promising potential for better cancer detection and diagnosis in practical applications of mammography.