Mads Jochumsen

Dr. Mads Jochumsen

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MRMuhammad Zia ur Rehman
Muhammad Zia ur Rehman
AWAsim Waris
Asim Waris
SGSyed Gilani
Syed Gilani
MJMads Jochumsen
Mads Jochumsen
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
EKErnest N. Kamavuako
Ernest N. Kamavuako
Pattern recognition of electromyography (EMG) signals can potentially improve the performance of myoelectric control for upper limb prostheses with respect to current clinical approaches based on direct control. However, the choice of features for classification is challenging and impacts long-term performance. Here, we propose the use of EMG raw signals as direct inputs to deep networks with intrinsic feature extraction capabilities recorded over multiple days. Seven able-bodied subjects performed six active motions (plus rest), and EMG signals were recorded for 15 consecutive days with two sessions per day using the MYO armband (MYB, a wearable EMG sensor). The classification was performed by a convolutional neural network (CNN) with raw bipolar EMG samples as the inputs, and the performance was compared with linear discriminant analysis (LDA) and stacked sparse autoencoders with features (SSAE-f) and raw samples (SSAE-r) as inputs. CNN outperformed (lower classification error) both LDA and SSAE-r in the within-session, between sessions on same day, between the pair of days, and leave-out one-day evaluation (p < 0.001) analyses. However, no significant difference was found between CNN and SSAE-f. These results demonstrated that CNN significantly improved performance and increased robustness over time compared with standard LDA with associated handcrafted features. This data-driven features extraction approach may overcome the problem of the feature calibration and selection in myoelectric control.

31 December 2015 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
Aqsa ShakeelAqsa Shakeel
Aqsa Shakeel
MNMuhammad Samran Navid
Muhammad Samran Navid
MAMuhammad Nabeel Anwar
Muhammad Nabeel Anwar
SMSuleman Mazhar
Suleman Mazhar
MJMads Jochumsen
Mads Jochumsen
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
The movement-related cortical potential (MRCP) is a low-frequency negative shift in the electroencephalography (EEG) recording that takes place about 2 seconds prior to voluntary movement production. MRCP replicates the cortical processes employed in planning and preparation of movement. In this study, we recapitulate the features such as signal’s acquisition, processing, and enhancement and different electrode montages used for EEG data recoding from different studies that used MRCPs to predict the upcoming real or imaginary movement. An authentic identification of human movement intention, accompanying the knowledge of the limb engaged in the performance and its direction of movement, has a potential implication in the control of external devices. This information could be helpful in development of a proficient patient-driven rehabilitation tool based on brain-computer interfaces (BCIs). Such a BCI paradigm with shorter response time appears more natural to the amputees and can also induce plasticity in brain. Along with different training schedules, this can lead to restoration of motor control in stroke patients.

28 August 2013 in Journal of Neural Engineering
Verified
Journal Article
Closed access
MJMads Jochumsen
Mads Jochumsen
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
NMNatalie Mrachacz-Kersting
Natalie Mrachacz-Kersting
DFDario Farina
Dario Farina
KDKim Dremstrup
Kim Dremstrup
In this study, the objective was to detect movement intentions and extract different levels of force and speed of the intended movement from scalp electroencephalography (EEG). We then estimated the performance of the closed loop system. Cued movements were detected from continuous EEG recordings using a template of the initial phase of the movement-related cortical potential in 12 healthy subjects. The temporal features, extracted from the movement intention, were classified with an optimized support vector machine. The system performance was evaluated when combining detection with classification. The system detected 81% of the movements and correctly classified 75 ± 9% and 80 ± 10% of these at the point of detection when varying the force and speed, respectively. When the detector was combined with the classifier, the system detected and correctly classified 64 ± 13% and 67 ± 13% of these movements. The system detected and incorrectly classified 21 ± 7% and 16 ± 9% of the movements. The movements were detected 317 ± 73 ms before the movement onset. The results indicate that it is possible to detect movement intentions with limited latencies, and extract and classify different levels of force and speed, which may be combined with assistive technologies for patient-driven neurorehabilitation.

1 April 2019 in Games for Health Journal
Verified
Journal Article
Closed access
Imran AmjadImran Amjad
Imran Amjad
Hamza Ghazanfar ToorHamza Ghazanfar Toor
Hamza Ghazanfar Toor
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
SPSanna Pervaiz
Sanna Pervaiz
MJMads Jochumsen
Mads Jochumsen
Touqeer AhmedTouqeer Ahmed
Touqeer Ahmed
Objectives: Physical activity and cognitive training are effective to enhance cognition in older patients with mild cognitive impairment (MCI). Xbox 360 Kinect cognitive games are a combination of physical activity and cognitive training. The objective of this study was to determine the short- and long-term effects of Xbox 360 Kinect cognitive games on slowness and complexity of electroencephalography (EEG) and cognitive functions in older subjects with MCI. Materials and Methods: A clinical trial was conducted on 44 MCI subjects. Both males and females were randomized into experimental group (participated in Xbox 360 Kinect cognitive games) and control group (range of motion exercises only and no Xbox 360 Kinect cognitive games). Subjects were assessed before and after one session of game intervention for short-term effects and after 6 weeks for long-term effects. The outcome measures were the mini-mental state examination (MMSE), Montreal cognitive assessment scale (MoCA), trail making test (TMT) A and B, and slowness and complexity of EEG. Results: After one session of game intervention, delta (0.704 ± 0.025; P = 0.013), theta (0.128 ± 0.009; P = 0.00127) waves, and complexity of EEG (0.642 ± 0.042; P = 0.008) significantly improved, in eyes closed state. Whereas after 6 weeks intervention of games, delta (0.673 ± 0.029; P = 0.013), theta (0.129 ± 0.013; P = 0.002), beta2 waves (0.044 ± 0.009; P = 0.046), complexity of EEG (0.051 ± 0.042; P = 0.016), MMSE (26.25 ± 0.347 vs. 23.722 ± 0.731; P = 0.003), MoCA (25.65 ± 0.310 vs. 22.00 ± 0.504; P = 0.0001), TMT-A (1.429 ± 0.234 vs. 2.225 ± 0.259; P = 0.028), and TMT-B (2.393 ± 0.201 vs. 3.780 ± 0.195; P = 0.0001) improved significantly. These changes were not observed in the control group. Conclusion: Xbox 360 Kinect games showed beneficial effects after short- and long-term intervention on MCI subjects. These games can serve as potential therapeutic candidates for MCI.

26 August 2015 in Journal of Neural Engineering
Verified
Journal Article
Closed access
MJMads Jochumsen
Mads Jochumsen
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
DTDenise Taylor
Denise Taylor
DFDario Farina
Dario Farina
KDKim Dremstrup
Kim Dremstrup
Objective . To detect movement intention from executed and imaginary palmar grasps in healthy subjects and attempted executions in stroke patients using one EEG channel. Moreover, movement force and speed were also decoded. Approach . Fifteen healthy subjects performed motor execution and imagination of four types of palmar grasps. In addition, five stroke patients attempted to perform the same movements. The movements were detected from the continuous EEG using a single electrode/channel overlying the cortical representation of the hand. Four features were extracted from the EEG signal and classified with a support vector machine (SVM) to decode the level of force and speed associated with the movement. The system performance was evaluated based on both detection and classification. Main results . ∼75% of all movements (executed, imaginary and attempted) were detected 100 ms before the onset of the movement. ∼60% of the movements were correctly classified according to the intended level of force and speed. When detection and classification were combined, ∼45% of the movements were correctly detected and classified in both the healthy and stroke subjects, although the performance was slightly better in healthy subjects. Significance . The results indicate that it is possible to use a single EEG channel for detecting movement intentions that may be combined with assistive technologies. The simple setup may lead to a smoother transition from laboratory tests to the clinic.

3 January 2013 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
NJNing Jiang
Ning Jiang
MJMads Jochumsen
Mads Jochumsen
JNJørgen Feldbæk Nielsen
Jørgen Feldbæk Nielsen
KDKim Dremstrup
Kim Dremstrup
DFDario Farina
Dario Farina
To allow a routinely use of brain–computer interfaces (BCI), there is a need to reduce or completely eliminate the time-consuming part of the individualized training of the user. In this study, we investigate the possibility of avoiding the individual training phase in the detection of movement intention in asynchronous BCIs based on movement-related cortical potential (MRCP). EEG signals were recorded during ballistic ankle dorsiflexions executed (ME) or imagined (MI) by 20 healthy subjects, and attempted by five stroke subjects. These recordings were used to identify a template (as average over all subjects) for the initial negative phase of the MRCPs, after the application of an optimized spatial filtering used for pre-processing. Using this template, the detection accuracy (mean ± SD) calculated as true positive rate (estimated with leave-one-out procedure) for ME was 69 ± 21 and 58 ± 11 % on single trial basis for healthy and stroke subjects, respectively. This performance was similar to that obtained using an individual template for each subject, which led to accuracies of 71 ± 6 and 55 ± 12 % for healthy and stroke subjects, respectively. The detection accuracy for the MI data was 65 ± 22 % with the average template and 60 ± 13 % with the individual template. These results indicate the possibility of detecting movement intention without an individual training phase and without a significant loss in performance.