Xiaoyu Wang

Dr. Xiaoyu Wang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Xiaolong JinXiaolong Jin
Xiaolong Jin
XWXiaoyu Wang
Xiaoyu Wang
Hongjie JiaHongjie Jia
Hongjie Jia
YMYunfei Mu
Yunfei Mu
QWQiuwei Wu
Qiuwei Wu
Wei WeiWei Wei
Wei Wei
Smart buildings in the integrated community energy system (ICES) are normally equipped with distributed energy resources (DERs), thereby creating building prosumers with both energy production and consumption. Peer-to-peer (P2P) energy trading among building prosumers can bring higher economic benefits for them. Therefore, a P2P multi-energy trading scheme among building prosumers is proposed, which fully explores the flexibility of buildings’ heating loads based on the thermal dynamics of buildings with different thermal insulation properties. Each building prosumer is heterogeneous in terms of its computation and communication infrastructures. This results in a heavy computation burden with the traditional centralized method. To improve the computational efficiency for P2P trading among heterogeneous building prosumers, an asynchronous distributed algorithm based on alternating direction method of multipliers (ADMM) is developed to enable each prosumer to trade energy asynchronously instead of waiting for the trading information from others with poor infrastructure. This asynchronous procedure integrated with the prediction and anomaly detection steps can further accelerate the convergence speed of P2P trading. Simulation results verify the effectiveness of the proposed trading scheme and the feasibility and solution optimality of the proposed algorithm.

1 April 2022 in Energy Reports
Verified
Journal Article
Open access
XWXiaoyu Wang
Xiaoyu Wang
TXTao Xu
Tao Xu
YMYunfei Mu
Yunfei Mu
ZWZibo Wang
Zibo Wang
Youjun DengYoujun Deng
Youjun Deng
HJHongjie Jia
Hongjie Jia

10 November 2022 in Energy Reports
Verified
Journal Article
Open access
XWXiaoyu Wang
Xiaoyu Wang
ZWZibo Wang
Zibo Wang
YMYunfei Mu
Yunfei Mu
YDYoujun Deng
Youjun Deng
HJHongjie Jia
Hongjie Jia

29 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
YSYinchi Shao
Yinchi Shao
YGYu Gong
Yu Gong
XWXiaoyu Wang
Xiaoyu Wang
XHXianmiao Huang
Xianmiao Huang
YZYang Zhao
Yang Zhao
SLShanna Luo
Shanna Luo
The increasing deployment of islanded microgrids in disaster-prone and infrastructure-constrained regions has elevated the importance of resilient energy storage systems capable of supporting autonomous operation. Grid-forming energy storage (GFES) units—designed to provide frequency reference, voltage regulation, and black-start capabilities—are emerging as critical assets for maintaining both energy adequacy and dynamic stability in isolated environments. However, conventional storage planning models fail to capture the interplay between uncertain renewable generation, time-coupled operational constraints, and control-oriented performance metrics such as virtual inertia and voltage ride-through. To address this gap, this paper proposes a novel distributionally robust optimization (DRO) framework that jointly optimizes the siting and sizing of GFES under renewable and load uncertainty. The model is grounded in Wasserstein-metric DRO, allowing worst-case expectation minimization over an ambiguity set constructed from empirical historical data. A multi-period convex formulation is developed that incorporates energy balance, degradation cost, state-of-charge dynamics, black-start reserve margins, and stability-aware constraints. Frequency sensitivity and voltage compliance metrics are explicitly embedded into the optimization, enabling control-aware dispatch and resilience-informed placement of storage assets. A tractable reformulation is achieved using strong duality and solved via a nested column-and-constraint generation algorithm. The framework is validated on a modified IEEE 33-bus distribution network with high PV penetration and heterogeneous demand profiles. Case study results demonstrate that the proposed model reduces worst-case blackout duration by 17.4%, improves voltage recovery speed by 12.9%, and achieves 22.3% higher SoC utilization efficiency compared to deterministic and stochastic baselines. Furthermore, sensitivity analyses reveal that GFES deployment naturally concentrates at nodes with high dynamic control leverage, confirming the effectiveness of the control-informed robust design. This work provides a scalable, data-driven planning tool for resilient microgrid development in the face of deep temporal and structural uncertainty.

23 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
LWLinlin Wu
Linlin Wu
YGYu Gong
Yu Gong
XWXiaoyu Wang
Xiaoyu Wang
YSYinchi Shao
Yinchi Shao
XHXianmiao Huang
Xianmiao Huang
YZYiming Zhao
Yiming Zhao
The integration of photovoltaic (PV) generation with alkaline water electrolyzers (AWE) in DC microgrids offers a highly promising pathway for green hydrogen production. However, the inherent volatility of solar power often induces transient voltage ripples and power surges, degrading the electrolyzer stack and destabilizing the common DC bus. To overcome this, this study proposes a hierarchical multimodal coordinated control strategy tailored for a four-port (PV–Storage–Grid–Hydrogen) DC microgrid. The proposed framework leverages multi-port synergetic coordination among the PV array, battery storage, and grid-interfacing converters to actively buffer extreme power mismatches, thereby ensuring the constant regulation of the DC bus voltage. Through comprehensive time-domain simulations under worst-case step-change boundary conditions, the large-signal transient stability of the proposed strategy is quantitatively verified. Under extreme disturbances, the system successfully confines DC bus voltage deviations to within safe operational boundaries with a rapid settling time, effectively avoiding typical inverter overvoltage trip thresholds. Furthermore, the adaptive power regulation algorithm maintains precise steady-state power tracking. By utilizing a gradient-based flag variable, the system seamlessly transitions between maximum power point tracking (MPPT) and active power-limiting modes, ensuring continuous equipment protection, stable high-purity hydrogen yield, and uninterrupted microgrid stability.

9 November 2026 in Energies
Verified
Journal Article
Open access
PDF file
XWXiaoyu Wang
Xiaoyu Wang
YGYu Gong
Yu Gong
YSYinchi Shao
Yinchi Shao
HXHuan Xie
Huan Xie
YZYang Zhao
Yang Zhao
XZXuesen Zhu
Xuesen Zhu
Large alkaline-water-electrolysis plants are increasingly formed by multiple converter-fed electrolysis units operating in parallel, whose grid interaction is affected by both operating condition and Buck control mode. This paper develops a control-mode-dependent small-signal dq-impedance model for an IGBT rectifier–dc-link–Buck–alkaline-water-electrolyzer unit under constant-current (CC) and constant-power (CP) control. The complete Buck–AWE input impedances are retained, and the electrochemical operating point is recalculated with loading. Frequency-sweep simulations of all four dq-impedance elements reproduce the principal analytical magnitude and phase characteristics, validating the mode-dependent model. The unit admittances are then aggregated for arbitrary CC/CP combinations, and grid interaction is evaluated using the minimum impedance phase-difference margin at all magnitude crossings. For four 1 MW units at λ = 0.75 and SCR = 3, the margin increases from −22.95° for 4 CC to +4.42° for 4 CP. Parameter studies show that loading, grid strength, and CC/CP composition jointly determine the impedance-interaction screening margin. HIL tests further show that mode reconfiguration produces distinct coupled ac–dc–electrochemical transients. These tests are used as qualitative time-domain corroboration of the control-mode-dependent dynamics rather than as a quantitative validation of the numerical value of Mφ.