Chen Yang

Prof. Chen Yang

Department of Electrical and Computer Engineering and Department of Chemistry, Boston University, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2022 in ACS Nano
Verified
Journal Article
Closed access
NZNan Zheng
Nan Zheng
VFVincent Fitzpatrick
Vincent Fitzpatrick
RCRan Cheng
Ran Cheng
LSLinli Shi
Linli Shi
DKDavid Kaplan
David Kaplan
Chen YangChen Yang
Chen Yang

14 July 2021 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
LSLinli Shi
Linli Shi
YJYing Jiang
Ying Jiang
FFFernando R. Fernandez
Fernando R. Fernandez
GCGuo Chen
Guo Chen
LLLu Lan
Lu Lan
Chen YangChen Yang
Chen Yang
Neuromodulation at high spatial resolution poses great significance in advancing fundamental knowledge in the field of neuroscience and offering novel clinical treatments. Here, we developed a tapered fiber optoacoustic emitter (TFOE) generating an ultrasound field with a high spatial precision of 39.6 µm, enabling optoacoustic activation of single neurons or subcellular structures, such as axons and dendrites. Temporally, a single acoustic pulse of sub-microsecond converted by the TFOE from a single laser pulse of 3 ns is shown as the shortest acoustic stimuli so far for successful neuron activation. The precise ultrasound generated by the TFOE enabled the integration of the optoacoustic stimulation with highly stable patch-clamp recording on single neurons. Direct measurements of the electrical response of single neurons to acoustic stimulation, which is difficult for conventional ultrasound stimulation, have been demonstrated. By coupling TFOE with ex vivo brain slice electrophysiology, we unveil cell-type-specific responses of excitatory and inhibitory neurons to acoustic stimulation. These results demonstrate that TFOE is a non-genetic single-cell and sub-cellular modulation technology, which could shed new insights into the mechanism of ultrasound neurostimulation.

1 February 2021 in Matter
Verified
Journal Article
Closed access
YJYing Jiang
Ying Jiang
YHYimin Huang
Yimin Huang
XLXuyi Luo
Xuyi Luo
JWJiayingzi Wu
Jiayingzi Wu
HZHaonan Zong
Haonan Zong
Chen YangChen Yang
Chen Yang

3 November 2022 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
YLYueming Li
Yueming Li
YJYing Jiang
Ying Jiang
LLLu Lan
Lu Lan
XGXiaowei Ge
Xiaowei Ge
RCRan Cheng
Ran Cheng
JCJi-Xin Cheng
Ji-Xin Cheng
High precision neuromodulation is a powerful tool to decipher neurocircuits and treat neurological diseases. Current non-invasive neuromodulation methods offer limited precision at the millimeter level. Here, we report optically-generated focused ultrasound (OFUS) for non-invasive brain stimulation with ultrahigh precision. OFUS is generated by a soft optoacoustic pad (SOAP) fabricated through embedding candle soot nanoparticles in a curved polydimethylsiloxane film. SOAP generates a transcranial ultrasound focus at 15 MHz with an ultrahigh lateral resolution of 83 µm, which is two orders of magnitude smaller than that of conventional transcranial-focused ultrasound (tFUS). Here, we show effective OFUS neurostimulation in vitro with a single ultrasound cycle. We demonstrate submillimeter transcranial stimulation of the mouse motor cortex in vivo. An acoustic energy of 0.6 mJ/cm2, four orders of magnitude less than that of tFUS, is sufficient for successful OFUS neurostimulation. OFUS offers new capabilities for neuroscience studies and disease treatments by delivering a focus with ultrahigh precision non-invasively.

14 February 2014 in Scientific Reports
Verified
Journal Article
Open access
WZWeixia Zhang
Weixia Zhang
SLSudarat Lee
Sudarat Lee
KMKelly L. McNear
Kelly L. McNear
TCTing Fung Chung
Ting Fung Chung
SLSeunghyun Lee
Seunghyun Lee
Chen YangChen Yang
Chen Yang
Corrosion of metal in biomedical devices could cause serious health problems to patients. Currently ceramics coating materials used in metal implants can reduce corrosion to some extent with limitations. Here we proposed graphene as a biocompatible protective film for metal potentially for biomedical application. We confirmed graphene effectively inhibits Cu surface from corrosion in different biological aqueous environments. Results from cell viability tests suggested that graphene greatly eliminates the toxicity of Cu by inhibiting corrosion and reducing the concentration of Cu2+ ions produced. We demonstrated that additional thiol derivatives assembled on graphene coated Cu surface can prominently enhance durability of sole graphene protection limited by the defects in graphene film. We also demonstrated that graphene coating reduced the immune response to metal in a clinical setting for the first time through the lymphocyte transformation test. Finally, an animal experiment showed the effective protection of graphene to Cu under in vivo condition. Our results open up the potential for using graphene coating to protect metal surface in biomedical application.

1 December 2020 in Photoacoustics
Verified
Journal Article
Open access
LSLinli Shi
Linli Shi
YJYing Jiang
Ying Jiang
YZYi Zhang
Yi Zhang
LLLu Lan
Lu Lan
YHYimin Huang
Yimin Huang
Chen YangChen Yang
Chen Yang
A fiber-based optoacoustic emitter is developed, serving as the most miniaturized ultrasound point source so far, with sub-millimeter confinement. Controllable frequencies are achieved and further induce cell membrane sonoporation with frequency dependent efficiency. By solving the problem of compromise between sub-MHz frequency and sub-millimeter precision via breaking the diffraction limit, the FOE shows a great potential in region-specific cell modulation.