As a common two-dimensional carbon material, graphene has been widely doped into polymers to prepare high-performance dielectric materials. However, the shortcomings of graphene, such as large specific surface area and poor dispersion, limit its further application. Therefore, in this work, to solve the problem regarding the uniform dispersion of graphene in the matrix, in situ polymerization was used to prepare graphene/polyimide films, in which 1,4-diiodobutane was used as a reduction agent to prevent the aggregation of graphene oxide (GO) during imidization. High dielectric constant composite films were obtained by adjusting the ratio of 1,4-diiodobutane in GO. The results show that the resulting graphene/polyimide composite film possessed a dielectric constant of up to 197.5, which was more than 58 times higher than that of the polyimide (PI) film. Furthermore, compared to the pure PI film, the composite films showed better thermal stability and mechanical properties. Thermal performance tests showed that the 1,4-diiodobutane added during the preparation of the composite film was thermally decomposed, and there was no residue. We believe our preparation method can be extended to other high dielectric composite films, which will facilitate their further development and application in high power density energy storage materials.
Since carbohydrate antigen 19-9 (CA 19-9) is a significant biomarker for the clinical diagnosis and treatment of pancreatic cancer, a sensitive sandwich-type immunosensor was proposed with an epoxy functionalized covalent organic framework (EP-COFTTA-DHTA) as the antibody carrier and an electroactive COFTTA-2,6-NA(OH)2 as the signal amplification probe for the sensitive detection of CA 19-9. The flexible covalent linkage between the epoxy-functionalized EP-COFTTA-DHTA and the antibodies was employed to improve the dynamics of the antigen–antibody interaction significantly. Meanwhile, AuNPs@COFTTA-2,6-NA(OH)2 with abundant electroactive sites enhanced the current response of the immunoreaction significantly. After optimizing the incubation time and concentration of the antibody, CA 19-9 was quantitatively detected by differential pulse voltammetry (DPV) based on the sensitive sandwich-type immunosensor with a low detection limit of 0.0003 U/mL and a wide linear range of 0.0009–100 U/mL. The electrochemical immunosensor exhibits high specificity, stability and repeatability, and it provides a feasible and efficient method for the pathologic analysis and treatment of tumor markers.