Homero David Cadena

Dr. Homero David Cadena

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2025 in Polymers
Verified
Journal Article
Open access
PDF file
Jorge Mauricio FuentesJorge Mauricio Fuentes
Jorge Mauricio Fuentes
HCHomero David Cadena
Homero David Cadena
Abel RemacheAbel Remache
Abel Remache
OFOmar Cristóbal Flor-Unda
Omar Cristóbal Flor-Unda
GSGeovanny Santiago Sarria
Geovanny Santiago Sarria
SFSantiago Ferrandiz
Santiago Ferrandiz
Polymers such as PLA, PLA reinforced with carbon fiber (PLA + CF), and PETG are widely employed in utensils, structural components, and biomedical device housings where load-bearing capability and chemical resistance are desirable. This is particularly relevant for reusable applications in which sterilization with hydrogen peroxide (HP) or ethylene oxide (EO) is often required. In this study, the impact of HP and EO sterilization processes on the mechanical, thermal, and structural properties of PLA, PLA + CF, and PETG was evaluated. The mechanical properties assessed included elongation at break, elastic modulus, and tensile strength after sterilization. The thermal properties examined comprised thermal stability and the coefficient of thermal expansion (CTE). Additionally, Fourier Transform Infrared Spectroscopy (FTIR) was performed to detect potential alterations in functional groups. For PLA, sterilization with HP and EO resulted in a 22% increase in ultimate tensile strength (UTS) and a 21% increase in elastic modulus, accompanied by a noticeable reduction in ductility and the appearance of more brittle fracture surfaces. PLA + CF exhibited greater stability under both sterilization methods due to the reinforcing effect of carbon fibers. In the case of PETG, tensile strength and stiffness remained stable; however, HP sterilization led to a remarkable increase in elongation at break (294%), whereas EO sterilization reduced it. Regarding thermal properties, glass transition temperature (Tg) showed variations: PLA presented either an increase or decrease in Tg depending on the sterilization treatment, PLA + CF displayed a Tg reduction after EO sterilization, while PETG exhibited a moderate Tg increase under HP sterilization. CTE decreased at lower temperatures but increased after EO treatment. FTIR analysis revealed only minor chemical modifications induced by sterilization. Overall, HP and EO sterilization can be safely applied to additively manufactured medical components based on these polymers, provided that the structures are not subjected to high mechanical loads and do not require strict dimensional tolerances.

Verified
Journal Article
Open access
PDF file
Abel RemacheAbel Remache
Abel Remache
Wilson PavonWilson Pavon
Wilson Pavon
OJOscar Jara-Vinueza
Oscar Jara-Vinueza
JCJosseline Chicaiza
Josseline Chicaiza
Jorge Mauricio FuentesJorge Mauricio Fuentes
Jorge Mauricio Fuentes
HCHomero David Cadena
Homero David Cadena
Fused deposition modeling (FDM) of carbon fiber-reinforced polycarbonate (PC-CF) is increasingly used in medical applications due to its excellent strength-to-weight ratio and adaptability for custom geometries. However, sterilization is a critical step that may compromise the structural integrity of polymer composites. This study investigates the effects of two low-temperature sterilization methods—ethylene oxide (EO) and hydrogen peroxide vapor (HP)—on the mechanical, thermal, and viscoelastic properties of FDM-printed PC-CF parts. Characterization included tensile, impact, and hardness tests; thermomechanical analysis (TMA); and dynamic mechanical analysis (DMA). EO sterilization resulted in approximately 20% reduced elongation at break and lower glass transition temperature, indicating a loss of ductility and thermal stability. HP-treated samples showed reduced stiffness (16% in Young modulus) but increased Tg and reduced thermal expansion, suggesting improved dimensional stability. DMA results confirmed distinct viscoelastic behavior between treatment types. These findings provide evidence for selecting appropriate sterilization protocols for FDM-manufactured PC-CF components used in functional medical devices.