Issei Kan

Dr. Issei Kan

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2015 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
IYI. Yuki
I. Yuki
YKY. Kambayashi
Y. Kambayashi
AIA. Ikemura
A. Ikemura
YAY. Abe
Y. Abe
IKIssei Kan
Issei Kan
YMYuichi Murayama
Yuichi Murayama
BACKGROUND AND PURPOSE: Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. MATERIALS AND METHODS: Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. RESULTS: Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P < .0001) and quantitative (P < .001) analyses showed significant reduction of the metal artifacts after application of the Metal Artifact Reduction prototype software. CONCLUSIONS: The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization.

30 January 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
AIA. Ikemura
A. Ikemura
TIT. Ishibashi
T. Ishibashi
KOKatharina Otani
Katharina Otani
IYI. Yuki
I. Yuki
TKT. Kodama
T. Kodama
YMYuichi Murayama
Yuichi Murayama
BACKGROUND AND PURPOSE: Delayed leukoencephalopathy is a rare complication that occurs after endovascular coiling of cerebral aneurysms. We aimed to describe a clinical picture of delayed leukoencephalopathy and explore potential associations with procedural characteristics. MATERIALS AND METHODS: We considered endovascular coiling procedures for cerebral aneurysms performed between January 2006 and December 2017 in our institution with follow-up MRIs. We used logistic regression models to estimate the ORs of delayed leukoencephalopathy for each procedural characteristic. RESULTS: We reviewed 1754 endovascular coiling procedures of 1594 aneurysms. Sixteen of 1722 (0.9%) procedures demonstrated delayed leukoencephalopathy on follow-up FLAIR MR imaging examinations after a median period of 71.5 days (interquartile range, 30–101 days) in the form of high-signal changes in the white matter at locations remote from the coil mass. Seven patients had headaches or hemiparesis, and 9 patients were asymptomatic. All imaging-associated changes improved subsequently. We found indications suggesting an association between delayed leukoencephalopathy and the number of microcatheters used per procedure (P = .009), along with indications suggesting that these procedures required larger median volumes of contrast medium (225 versus 175 mL, OR = 5.5, P = .008) as well as a longer median fluoroscopy duration (123.6 versus 99.3 minutes, OR = 3.0, P = .06). Our data did not suggest that delayed leukoencephalopathy was associated with the number of coils (P = .57), microguidewires (P = .35), and guiding systems (P = .57). CONCLUSIONS: Delayed leukoencephalopathy after coiling of cerebral aneurysms may have multiple etiologies such as foreign body emboli, contrast-induced encephalopathy, or hypersensitivity reaction to foreign bodies.

1 February 2020 in World Neurosurgery
Verified
Journal Article
Closed access
IKIssei Kan
Issei Kan
TIToshihiro Ishibashi
Toshihiro Ishibashi
KSKenichi Sakuta
Kenichi Sakuta
SFSoichiro Fujimura
Soichiro Fujimura
IYIchiro Yuki
Ichiro Yuki
YMYuichi Murayama
Yuichi Murayama

1 December 2020 in Journal of Stroke and Cerebrovascular Diseases
Verified
Journal Article
Closed access
NKNaoki Kato
Naoki Kato
IYIchiro Yuki
Ichiro Yuki
SHShunsuke Hataoka
Shunsuke Hataoka
CDChihebeddine Dahmani
Chihebeddine Dahmani
KOKatharina Otani
Katharina Otani
YMYuichi Murayama
Yuichi Murayama

17 January 2024 in Frontiers in Neurology
Verified
Journal Article
Open access
KAKen Aoki
Ken Aoki
YMYuichi Murayama
Yuichi Murayama
YTYoshihiro Tanaka
Yoshihiro Tanaka
TIToshihiro Ishibashi
Toshihiro Ishibashi
KIKoreaki Irie
Koreaki Irie
GNGota Nagayama
Gota Nagayama
Introduction: Intraprocedural rupture (IPR) is a serious complication of endovascular coil embolization of unruptured intracranial aneurysms (UIAs). Although outcomes after IPR are poor, methods to prevent subsequent neurological deterioration have not yet been investigated. We evaluated the risk factors and management strategies for IPR, particularly the role of balloon guiding catheters (BGCs) in rapid hemostasis.Methods: We retrospectively reviewed all UIA cases treated with coil embolization at three institutions between 2003 and 2021, focusing on preoperative radiological data, operative details, and outcomes.Results: In total, 2,172 aneurysms were treated in 2026 patients. Of these, 19 aneurysms in 19 patients (0.8%) ruptured during the procedure. Multivariate analysis revealed that aneurysms with a bleb (OR: 3.03, 95% CI: 1.21 to 7.57, p = 0.017), small neck size (OR: 0.56, 95% CI: 0.37 to 0.85, p = 0.007), and aneurysms in the posterior communicating artery (PcomA) (OR: 4.92, 95% CI: 1.19 to 20.18, p = 0.027) and anterior communicating artery (AcomA) (OR: 12.08, 95% CI: 2.99 to 48.79, p < 0.001) compared with the internal carotid artery without PcomA were significantly associated with IPR. The incidence of IPR was similar between the non-BGC and BGC groups (0.9% vs. 0.8%, p = 0.822); however, leveraging BGC was significantly associated with lower morbidity and mortality rates after IPR (0% vs. 44%, p = 0.033).Discussion: The incidence of IPR was relatively low. A bleb, small aneurysm neck, and location on PcomA and AcomA are independent risk factors for IPR. The use of BGC may prevent fatal clinical deterioration and achieve better clinical outcomes in patients with IPR.

1 December 2020 in World Neurosurgery
Verified
Journal Article
Closed access
SKShota Kakizaki
Shota Kakizaki
TIToshihiro Ishibashi
Toshihiro Ishibashi
NKNaoki Kato
Naoki Kato
IKIssei Kan
Issei Kan
KNKengo Nishimura
Kengo Nishimura
YMYuichi Murayama
Yuichi Murayama