Trinh Quoc Nam

Trinh Quoc Nam

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TNTrinh Quoc Nam
Trinh Quoc Nam
PWPeng Wang
Peng Wang
YTYi Tang
Yi Tang
LKLeong Hai Koh
Leong Hai Koh
FCFook Hoong Choo
Fook Hoong Choo
The dc offset and scaling errors in the voltage and current measurements cause the injection of undesired dc and unbalanced currents into the three-phase input currents and subsequently lead to voltage ripple at the dc output voltage of the ac/dc converter. This paper proposes a compensation scheme for current measurement error where the dc offset and scaling errors in the current measurement are estimated from the voltage ripple characteristics of the dc output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, the dc offset and scaling errors in the voltage measurement can be rejected by using an advanced current controller developed with a proportional resonant plus a repetitive controller designed in the synchronous (d-q) reference frame. The proposed control algorithm is able to effectively reject the impact of both voltage and current measurement error so that the three-phase input currents are regulated to be balanced and sinusoidal with ultralow dc current component. Meanwhile, the dc output voltage is also well regulated to be pure dc with a negligibly small voltage ripple. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.

16 October 2017 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
TNTrinh Quoc Nam
Trinh Quoc Nam
Peng WangPeng Wang
Peng Wang
YTYi Tang
Yi Tang
FCFook Hoong Choo
Fook Hoong Choo
The DC offset and scaling errors in the voltage measurements cause the injection of undesired DC and harmonic currents into the three-phase output currents of the grid-connected inverter. This study proposes an enhanced current control scheme to eliminate the DC and harmonic currents caused by voltage distortion and voltage measurement error in three-phase grid-connected inverters. The proposed current controller is designed in the synchronous (d-q) reference frame and composed of a proportional resonant (PR) controller and a repetitive controller (RC). The role of the RC is to regulate the grid current follow the reference value as well as compensate all $6{\mathrm n}\omega_{\mathrm{s}}$ and $(6{\mathrm n}\pm2)_\omega_s$ (${\mathrm n} = 1, 2, 3\ldots$) harmonic components caused by distorted grid voltage and scaling errors. Meanwhile, the PR controller helps to compensate the DC current generated by DC offset measurement errors to guarantee the three-phase grid currents are balanced and sinusoidal with extremely low DC component. Since the RC employed in the proposed current controller reduces to time delay by four times compared to the conventional RC, the proposed control system ensures good steady-state performance of the grid current without deteriorating its fast dynamic response. The effectiveness of the suggested solution is verified by various experimental tests.

14 March 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TNTrinh Quoc Nam
Trinh Quoc Nam
FCFook Hoong Choo
Fook Hoong Choo
PWPeng Wang
Peng Wang
This study proposes an advanced current control strategy for three-phase grid-connected inverters to reject the impact of the dc offsets and scaling errors in the grid voltage measurement on the grid current performance. The proposed current controller designed in the synchronous (d-q) reference frame is developed with a proportional integral (PI) plus three vector PI controllers. The PI controller regulates the fundamental current to follow its reference, meanwhile, three vector PI controllers tuned at the fundamental grid frequency (ω 8 ), 2ω 8 , 6ω 8 are employed to eliminate the dc, unbalance, harmonic components in the grid current. As a result, the three-phase grid currents are controlled to be balanced, sinusoidal, and extremely low dc component despite the presence of the dc offset and scaling errors in the grid voltage measurement and distorted grid voltage conditions. The main advantage of the proposed control scheme is that it is developed without the need of additional hardware circuit, dc extraction, and harmonic detection scheme so that it can be integrated into the existing grid-connected inverter system without extra cost. The effectiveness of the suggested solution is verified by experimental results under various grid voltage conditions and the grid voltage measurement errors.

16 February 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
TNTrinh Quoc Nam
Trinh Quoc Nam
PWPeng Wang
Peng Wang
FCFook Hoong Choo
Fook Hoong Choo
This paper proposes an enhanced current control strategy to reject the impact of dc-offset measurement error and the distortion in the supply voltage on the dc output voltage and the input current performance of three-phase pulsewidth modulation rectifiers. The proposed current controller designed in the synchronous reference frame is developed with a proportional integral (PI) and two vector PI (VPI) controllers. The PI controller regulates the fundamental current to follow its reference generated from outer dc-link voltage control, meanwhile two VPI controllers tuned at the fundamental grid frequency (ω s ) and 6ω s are employed to eliminate the dc and harmonic components in the input current. Compared with the standard resonant controllers, the proposed VPI controller offers some advantages such as simpler and straightforward tuning process for controller gains and more robust control system against control delay time and frequency variations. Thanks to the effectiveness of the VPI controllers, the dc output voltage is controlled at a stable manner without any ac ripple, and the three-phase input currents are controlled to be balanced, sinusoidal, and extremely low dc component despite the presence of the dc-offset measurement error and distorted supply voltage conditions. Various experimental tests are provided to verify the effectiveness of the proposed control algorithm.

18 January 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
TNTrinh Quoc Nam
Trinh Quoc Nam
FCFook Hoong Choo
Fook Hoong Choo
YTYi Tang
Yi Tang
Peng WangPeng Wang
Peng Wang
This study introduces a compensation strategy to deal with both current and voltage measurement errors in the threephase PWM rectifier system. The DC offset and scaling errors in the voltage and current measurements cause the injection of undesired DC and unbalanced currents into the three-phase input current and subsequently lead to voltage ripple at the DC output voltage. This paper proposes a compensation scheme for current measurement error where the DC offset and scaling errors in the current measurement are estimated from the characteristic of the DC output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, an advanced current controller designed with a proportional integral plus two resonant controllers tuned at the fundamental grid frequency (ω $_s$ ) and 2ω $_s$ in the synchronous (d-q) reference frame is suggested to reject the impact of the DC offset and scaling errors in the voltage measurement. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost-effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.

1 May 2015 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
TNTrinh Quoc Nam
Trinh Quoc Nam
HLHong-Hee Lee
Hong-Hee Lee
Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters Unified power quality conditioner;Four-switch inverter;Low cost;Harmonic compensation; This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.