Zahra Rafiee

Zahra Rafiee


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2020 in IEEE Access
Verified
Journal Article
Open access
Jose RodriguezJose Rodriguez
Jose Rodriguez
RHRasool Heydari
Rasool Heydari
ZRZahra Rafiee
Zahra Rafiee
Hector YoungHector Young
Hector Young
Freddy Flores-BahamondeFreddy Flores-Bahamonde
Freddy Flores-Bahamonde
Mahdi ShahparastiMahdi Shahparasti
Mahdi Shahparasti
Conventional model predictive control (MPC) of power converter has been widely applied to power inverters achieving high performance, fast dynamic response, and accurate transient control of power converter. However, the MPC strategy is highly reliant on the accuracy of the inverter model used for the controlled system. Consequently, a parameter or model mismatch between the plant and the controller leads to a sub-optimal performance of MPC. In this paper, a new strategy called model-free predictive control (MF-PC) is proposed to improve such problems. The presented approach is based on a recursive least squares algorithm to identify the parameters of an auto-regressive with exogenous input (ARX) model. The proposed method provides an accurate prediction of the controlled variables without requiring detailed knowledge of the physical system. This new approach and is realized by employing a novel state space identification algorithm into the predictive control structure. The performance of the proposed model-free predictive control method is compared with conventional MPC. The simulation and experimental results show that the proposed method is totally robust against parameters and model changes compared with the conventional model based solutions.

16 March 2022 in IEEE Systems Journal
Verified
Journal Article
Closed access
ZRZahra Rafiee
Zahra Rafiee
RHRasool Heydari
Rasool Heydari
MRMansour Rafiee
Mansour Rafiee
MAMohammad Reza Aghamohammadi
Mohammad Reza Aghamohammadi
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
In this article, an advanced transient voltage control (A-TVC) strategy is proposed to enhance the low-voltage ride-through (LVRT) capability of a doubly fed induction generator (DFIG)-based wind farm (WF). In severe voltage dip (VD) conditions, the DFIG-based WF should stay online to support the grid voltage. However, it may lead to transient voltage instability in the grid. This article proposes a novel A-TVC, which follows the VD conditions and, consequently, improves the LVRT capability of the DFIG-based WF. In this approach, a lookup table is presented to control the transient voltage based on the short-circuit capacity at the point of common coupling (PCC), VD index on the grid, and generated power limitations of the DFIG. By applying the proposed control strategy, the DFIG could not only smooth the dc-link voltage fluctuations and reduce the stator and rotor overcurrents in a faulty grid but also increase the PCC and stator voltages and, thus, enhance the transient voltage stability. Simulations and control-hardware-in-the-loop experimental results validate the effectiveness of the proposed control strategy for improving the LVRT capability of the DFIG in severe balanced and unbalanced VD conditions.

1 March 2020 in Physica C: Superconductivity and its Applications
Verified
Journal Article
Closed access
ZRZahra Rafiee
Zahra Rafiee
SNSeyed Sajad Najafi
Seyed Sajad Najafi
MRMansour Rafiee
Mansour Rafiee
MAMohammad Reza Aghamohammadi
Mohammad Reza Aghamohammadi
MPMahdi Pourgholi
Mahdi Pourgholi

1 February 2020 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
ZRZahra Rafiee
Zahra Rafiee
MRMansour Rafiee
Mansour Rafiee
MAMohammad Reza Aghamohammadi
Mohammad Reza Aghamohammadi
The paper presents the transient behavior of the doubly fed induction generator (DFIG) in the wind turbine (WT) in the normal and voltage dip condition. When voltage dip occurs in to the grid, the rotor current increases and the DC-link voltage increases too and start to oscilate. In this paper, the proportional integral (PI) controllers are used to control the DFIG-basedwind farms for regulating the electronic devices including rotor side converter (RSC) and grid side converter (GSC) to control the active and reactive power of DFIG. The PI parameters are tuned by imperialist competitive algorithm (ICA). So, the transient behavour of the DFIG-based WF is explors when the voltage dip occurs. Hence, the induced electric motive force in to the rotor is measured. Also, an existed uncertainty for mutual inductance is considered caused by saturated curve during three-phase fault conditions and the bahavour of DFIG-based WT is examined and analyzed. All of simulation is done by Matlab/Simulink®.

12 June 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
ZRZahra Rafiee
Zahra Rafiee
MRMansour Rafiee
Mansour Rafiee
MAMohammadreza Aghamohammadi
Mohammadreza Aghamohammadi
The paper presents dynamic and transient behaviour of the Doubly Fed Induction Generator (DFIG) in the wind farms. When Voltage sag or any faults occurs in the network, the variables in the doubly Fed Induction Generators are varying severely. If the voltage sag occurs, Active and Reactive power that generated by the DFIG will decrease and will increase respectively, The DC voltage link will be bigger, and the rotor current will increase. The DFIG in the wind farms uses Proportional Integral controller for controlling of electronic devices (Rotor Side Converter and Grid Side Converter). Even though the model of Doubly Fed Induction Generators and electronic device in the paper are linear, The Proportional Integral controllers cannot protect and control the variables. So, the power electronic converters and the DC-link can damage due to over voltages and over currents. Doubly Fed Induction Generator in the wind farm is simulated in MATLAB software. The results of the simulation present over voltage and over current in the DC-link and in the rotor of the Doubly Fed Induction Generator. In addition, it will explore the effect of Proportional Integral controller in Doubly Fed Induction Generator when three-phase short circuit fault occurs

30 March 2021 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
ZRZahra Rafiee
Zahra Rafiee
SHSalman Hajiaghasi
Salman Hajiaghasi
MRMansour Rafiee
Mansour Rafiee
ASAhmad Salemnia
Ahmad Salemnia