Ran Chen

Dr. Ran Chen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
DLDong Liu
Dong Liu
ZLZhenyu Liu
Zhenyu Liu
Shilun FengShilun Feng
Shilun Feng
ZGZehang Gao
Zehang Gao
RCRan Chen
Ran Chen
Shengtai BianShengtai Bian
Shengtai Bian
Traditional exercise training monitoring is based on invasive blood testing methods. As sweat can reveal abundant blood-related physiological information about health, wearable sweat sensors have received significant research attention and become increasingly popular in the field of exercise training monitoring. However, most of these sensors are used to measure physical indicators such as heart rate, blood pressure, respiration, etc., demanding a versatile sensor that can detect relevant biochemical indicators in body fluids. In this work, we proposed a wearable microfluidic sweat chip combined with smartphone image processing to realize non-invasive in situ analysis of epidermal sweat for sports practitioners. The polydimethylsiloxane (PDMS) based chip was modified with nonionic surfactants to ensure good hydrophilicity for the automatic collection of sweat. Besides, a simple, reliable, and low-cost paper-based sensor was prepared for high-performance sensing of glucose concentration and pH in sweat. Under optimized conditions, this proposed chip can detect glucose with low concentrations from 0.05 mM to 0.40 mM, with a pH range of 4.0 to 6.5 for human sweat. The ability of this microfluidic chip for human sweat analysis was demonstrated by dynamically tracking the changes in glucose concentration and pH in long-distance running subjects.

30 November 2025 in Analytica Chimica Acta
Verified
Journal Article
Closed access
YQYiyue Qu
Yiyue Qu
RCRan Chen
Ran Chen
JCJie Chen
Jie Chen
QLQian Li
Qian Li
MAMostafa R. Abukhadra
Mostafa R. Abukhadra
Shengtai BianShengtai Bian
Shengtai Bian

21 August 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
Shengtai BianShengtai Bian
Shengtai Bian
JCJie Chen
Jie Chen
RCRan Chen
Ran Chen
Shilun FengShilun Feng
Shilun Feng
ZMZizhen Ming
Zizhen Ming
Microneedles represent an emerging transdermal drug delivery platform offering painless, minimally invasive penetration of the stratum corneum. This study addresses limitations of conventional lidocaine hydrochloride formulations, such as slow onset and poor patient compliance, by developing lidocaine hydrochloride-loaded dissolvable microneedles (LH-DMNs) for rapid local anesthesia. LH-DMNs were fabricated via centrifugal casting using polyvinyl alcohol (PVA) as the matrix material in polydimethylsiloxane (PDMS) negative molds, which imparts high mechanical strength to the microneedles. Biocompatibility assessments showed negligible skin irritation, resolving within 3 min. And drug-loading capacity reached 24.0 ± 2.84 mg per patch. Pharmacodynamic evaluation via mouse hot plate tests demonstrated significant analgesia, increasing paw withdrawal latency to 36.11 ± 1.62 s at 5 min post-application (p < 0.01). The results demonstrated that the LH-DMNs significantly elevated the pain threshold in mice within 5 min, surpassing the efficacy of conventional anesthetic gels and providing a rapid and effective solution for pain relief. These findings validate the system’s rapid drug release and efficacy, positioning dissolvable microneedles as a clinically viable alternative for enhanced transdermal anesthesia.