Jian Wang

Dr. Jian Wang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2013 in Journal of Convergence Information Technology
Verified
Journal Article
Closed access
JWJian Wang
Jian Wang
WKWu Kuihua
Wu Kuihua
AAAsif Ali
Asif Ali
WKWu Kuizhong
Wu Kuizhong
LZLi Zhihui
Li Zhihui

20 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
XWXuelei Wang
Xuelei Wang
LLLonglong Li
Longlong Li
JWJian Wang
Jian Wang
QZQingdong Zhu
Qingdong Zhu
ZGZhaoliang Gu
Zhaoliang Gu
MZMengzhao Zhu
Mengzhao Zhu
As a key component for maintaining the efficient and stable operation of flexible DC transmission systems, the arm reactor often suffers from uneven loss distribution and localized overheating in its windings due to the superimposed AC and DC currents, which adversely affects its operational lifespan. Furthermore, arm reactors are frequently deployed in offshore environments for long-distance, high-capacity power transmission, imposing additional requirements on energy utilization efficiency and seismic resistance. To address these challenges, this study proposes an optimization design method for arm reactors based on a triple-constraint mechanism of “equal resistive voltage–equal loss density–equal encapsulation temperature rise,” aiming to achieve “low loss–low temperature rise–low weight.” First, an equivalent electromagnetic model of the arm reactor under combined AC and DC operating conditions is established to analytically calculate the self- and mutual-inductance-distribution characteristics between winding layers and the loss distribution across windings. The calculated losses are then applied as heat sources in a fluid–thermal coupling method to compute the temperature field of the arm reactor. Next, leveraging a Kriging surrogate model to capture the relationship between the winding temperature rise in the bridge-arm reactor and the loss density, encapsulation width, encapsulation height, and air duct width, the revised analytical expression reduces the temperature rise error from 43.74% to 11.47% compared with the traditional empirical formula. Finally, the triple-constraint mechanism of “equal resistive voltage–equal loss density–equal encapsulation temperature rise” is proposed to balance interlayer current distribution, suppress total loss generation, and limit localized hotspot formation. A prototype constructed based on the optimized design demonstrates a 44.51% reduction in total loss, a 39.66% decrease in hotspot temperature rise, and a 24.83% reduction in mass while maintaining rated inductance, validating the effectiveness of the proposed design algorithm.