High penetration of distributed generation (DG) is mainly constrained by voltage related issues. Due to the uncertainties associated with type, size and location of DGs, it is difficult to quantify their integration limits in distribution networks, i.e., hosting capacity (HC). To address this issue, this paper proposes a probabilistic based framework to determine the maximum integration limits of DGs considering the voltage rise and voltage deviation constraints. Such framework requires use of the HC model, which can be formulated as a nonlinear optimization problem. Adding the voltage deviation constraint in the HC problem makes the model unsolvable. We address this issue by proposing a two-step algorithm to linearize the HC model. Then, using the linearized model, a probabilistic framework is proposed for considering the load variability and DGs uncertainties. To validate the efficacy and accuracy of the proposed framework, we identify the HC of a balanced and an unbalanced distribution networks and compare our results with those obtained from comprehensive power flow method and the traditional conservative planning. Finally, using the proposed framework, the impact of voltage deviation constraint, load growth, DG type and network structure on the HC are comprehensively studied using different DG technologies (i.e., Photovoltaics and wind).
The increasing integration of rooftop photovoltaic (PV) systems in low voltage (LV) distribution systems may result in technical problems such as over-voltage. Thus, utilities have been employing different active distribution network management schemes to enhance rooftop photovoltaic hosting capacity (PVHC) by mitigating the technical issues. As there are different control schemes to resolve the over-voltage issue and increase PVHC, it is necessary to develop a comprehensive method to compare their effectiveness. The aim of this paper is to investigate the effects of autonomous voltage control strategies on the PVHC in LV distribution feeders. The investigated operation strategies are based on the active and reactive power control capabilities of PV systems as well as the on-load tap changer of transformers. We propose an optimization-based framework to determine the PVHC considering the voltage control capabilities. We do this by utilizing the linear mathematical model of the PVHC, in which the voltage control strategies are modeled as equality and inequality constraints. The proposed methodology is examined on IEEE 123-bus test system as well as 128 LV UK feeders to identify the potential of autonomous voltage control strategies in increasing the PVHC. Finally, the sensitivity of the obtained results to the R/X ratio of the feeders and size of PV systems is assessed.
Uncertainties associated with the loads and the output power of distributed generations create challenges in quantifying the integration limits of distributed generations in distribution networks, i.e., hosting capacity. To address this, we propose a distributionally robust optimization-based method to determine the hosting capacity considering the voltage rise, thermal capacity of the feeders and short circuit level constraints. In the proposed method, the uncertain variables are modeled as stochastic variables following ambiguous distributions defined based on the historical data. The distributionally robust optimization model guarantees that the probability of the constraint violation does not exceed a given risk level, which can control robustness of the solution. To solve the distributionally robust optimization model of the hosting capacity, we reformulated it as a joint chance constrained problem, which is solved using the sample average approximation technique. To demonstrate the efficacy of the proposed method, a modified IEEE 33-bus distribution system is used as the test-bed. Simulation results demonstrate how the sample size of historical data affects the hosting capacity. Furthermore, using the proposed method, the impact of electric vehicles aggregated demand and charging stations are investigated on the hosting capacity of different distributed generation technologies.
A new control scheme to improve in dynamic response of parallel inverters is proposed in this paper. The conventional droop method is a good choice for managing microgrid in a decentralized manner. The proposed control technique, based on the droop control method, uses current feedback signal and Power Angle of VSIs. This method is usually applied to achieve good active and reactive power sharing and decreasing circulating current in transient. In this work, a great improvement in transient response is achieved by introducing this new droop for voltage and frequency. Simulation results that validate the proposed controller are provided.
In future smart grids, energy storage systems (EESs) and demand response (DR) are expected to have an important role in balancing load changes arising from life-style of consumers and varying output of some renewable energy resources. However, activating DR and installing ESSs need huge investment forcing system owner to justify their effectiveness prior to any implementation. This paper presents a model to find the optimal capacity of EESs in distribution systems with demand responding to electricity price changes. The model aims at maximizing system owner profit by lessening total electricity provision costs. The model is formulated as a mixed integer non-linear programming problem. Due to the intricacy and big size of the problem, a decouple-based procedure is proposed wherein optimal charge/discharge pattern of EESs is found by means of a quadratic programming (QP) model. The method is applied to the IEEE 33-bus network and simulation results are thoroughly discussed.
Energy storage systems (EES) are expected to be an indispensable resource for mitigating the effects on networks of high penetrations of distributed generation in the near future. This paper analyzes the benefits of EES in unbalanced low voltage (LV) networks regarding three aspects, namely, power losses, the hosting capacity and network unbalance. For doing so, a mixed integer quadratic programmming model (MIQP) is developed to minimize annual energy losses and determine the sizing and placement of ESS, while satisfying voltage constraints. A real unbalanced LV UK grid is adopted to examine the effects of ESS under two scenarios: the installation of one community ESS (CESS) and multiple distributed ESSs (DESSs). The results illustrate that both scenarios present high performance in accomplishing the above tasks, while DESSs, with the same aggregated size, are slightly better. This margin is expected to be amplified as the aggregated size of DESSs increases.