Despite the wide-spread use of antiseptics in dental practice and oral care products, there is little public awareness of potential risks associated with antiseptic resistance and potentially concomitant cross-resistance. Therefore, the aim of this study was to investigate potential phenotypic adaptation in 177 clinical isolates of early colonizers of dental plaque (Streptococcus, Actinomyces, Rothia and Veillonella spp.) upon repeated exposure to subinhibitory concentrations of chlorhexidine digluconate (CHX) or cetylpyridinium chloride (CPC) over 10 passages using a modified microdilution method. Stability of phenotypic adaptation was re-evaluated after culture in antiseptic-free nutrient broth for 24 or 72 h. Strains showing 8-fold minimal inhibitory concentration (MIC)-increase were further examined regarding their biofilm formation capacity, phenotypic antibiotic resistance and presence of antibiotic resistance genes (ARGs). Eight-fold MIC-increases to CHX were detected in four Streptococcus isolates. These strains mostly exhibited significantly increased biofilm formation capacity compared to their respective wild-type strains. Phenotypic antibiotic resistance was detected to tetracycline and erythromycin, consistent with the detected ARGs. In conclusion, this study shows that clinical isolates of early colonizers of dental plaque can phenotypically adapt toward antiseptics such as CHX upon repeated exposure. The underlying mechanisms at genomic and transcriptomic levels need to be investigated in future studies.
Electromagnetic acoustic resonance (EMAR) is a well-established non-contact method for ultrasonic thickness measurement, typically operated at frequencies above 1 MHz using an electromagnetic acoustic transducer (EMAT). This study successfully extends EMAR into the sub-MHz range, allowing supply voltages below 60 V and thus offering safer and more cost-effective operation. Experiments were conducted on copper blocks approximately 20 mm thick, where a relative thickness accuracy of better than 0.2% is obtained. Regarding this result, the research identifies a critical design principle: Stable thickness resonances and subsequently accurate thickness measurement are achieved when the ratio of ultrasonic wavelength to EMAT track width (/w) falls below 1. This minimizes the excitation and interactions with structural eigenmodes, ensuring consistent measurement reliability. To support this, the study introduces a system-based model to simulate the EMAR method. The model provides detailed insights into how wave propagation affects the accuracy of EMAR measurements. Experimental results align well with the simulation outcome and confirm the feasibility of EMAR in the sub-MHz regime without compromising precision. These findings highlight the potential of low-voltage EMAR as a safer, cost-effective, and highly accurate approach for industrial ultrasonic thickness measurements.
23 March 2022 in e+i Elektrotechnik und Informationstechnik
This paper investigates the use of PCB motors for sub-fractional HP auxiliary fan drives. First, the basic idea of PCB motors as well as the main advantages and disadvantages are discussed, followed by the description of the design process for a PCB motor for a small automotive fan application. Three different stator designs have been implemented, each on a 4-layer PCB. Finally, the paper gives an overview of the measurements performed and the results obtained for the prototypes of the manufactured PCB motors and suggests design improvements.
19 December 2023 in Photochemical & Photobiological Sciences
The widespread occurrence of multi-resistant bacteria is a health problem of global dimension. Infections caused by multi-resistant pathogens are difficult to treat and often associated with high mortality. Therefore, new treatment strategies are of interest, such as the use of differently acting antibacterial concepts. One of these new concepts is the use of antiseptics in combination with the antibacterial photodynamic therapy (aPDT). Currently, no method has yet been established as a standard procedure for investigating combined effects and evaluating them in a generally valid and unambiguous manner. The focus of this study was on how cationic antiseptics benzalkonium chloride (BAC) and chlorhexidine digluconate (CHX) behave in a combined application with aPDT using the photosensitizer TMPyP. For this purpose, BAC and CHX were applied in combination with the aPDT using TMPyP in non-lethal concentrations to the three bacteria Escherichia coli, Staphylococcus aureus, and Enterococcus faecalis. The results of the combination experiments with sublethal concentrations of BAC or CHX with the aPDT showed that the binary application had a lethal effect. Irrespective of the bacteria, the reduction in concentrations in OPECC, compared to individual concentrations, was more than 50% for TMPyP, 23–40% for BAC, and 18–43% for CHX. Furthermore, the optimal effective concentration combinations (OPECCs) could be determined. The latter showed that the combined application allowed the reduction of both concentrations compared to the single application.