Wenjun Wu

Dr. Wenjun Wu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in Metrologia
Verified
Journal Article
Closed access
XLXiaotong Lu
Xiaotong Lu
FGFeng Guo
Feng Guo
YWYebing Wang
Yebing Wang
QXQinfang Xu
Qinfang Xu
CZChihua Zhou
Chihua Zhou
HCHong Chang
Hong Chang
We report the absolute frequency measurement of the 5 s 2 1 S 0 → 5 s 5 p 3 P 0 transition in 87Sr optical lattice clock (Sr1) at National Time Service Center. Its systematic frequency shifts are evaluated carefully with a total relative uncertainty of 5.1 × 10 − 17 . The measured absolute frequency is 429 228 004 229 872.91(18) Hz with a relative uncertainty of 4.1 × 10 − 16 , with reference to the ensemble of primary and secondary frequency standards published in the Circular T bulletin by BIPM through a global navigation satellite system link.

6 February 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
QXQinfang Xu
Qinfang Xu
XLXiaotong Lu
Xiaotong Lu
SWShanhe Wang
Shanhe Wang
FGFeng Guo
Feng Guo
WWWenjun Wu
Wenjun Wu
HCHong Chang
Hong Chang
Owing to their exceptional performance characteristics, optical atomic clocks enable the generation of time scales that demonstrate superior accuracy and stability compared to conventional microwave clocks. This paper presents an experimental optical time scale based on the NTSC-SrⅡ optical lattice clock as the reference and a hydrogen maser as the flywheel oscillator. The time scale TS (SrⅡ), generated through post-processing analysis over a two-month period, achieves a peak-to-peak time variation of 0.39 ns relative to Coordinated Universal Time (UTC) and reaches a frequency stability of 1.94 × 10 −16 at 5 d. In addition, a physical optical time scale TS*(SrⅡ) was realized for approximately one month, and the peak-to-peak time difference is 0.3 ns compared to UTC. These results demonstrate that optical time scales maintain competitive performance even when the optical clock operates with limited and non-uniformly distributed uptime. This work constitutes an essential step toward a redefinition of the second of the International System of Units based on an optical transition.

8 November 2022 in arXiv
Verified
Preprint
Open access
PDF file
XLXiaotong Lu
Xiaotong Lu
FGFeng Guo
Feng Guo
YWYebing Wang
Yebing Wang
QXQinfang Xu
Qinfang Xu
CZChihua Zhou
Chihua Zhou
HCHong Chang
Hong Chang
We report the absolute frequency measurement of the 5s2 1S0-5s5p 3P0 transition in 87Sr optical lattice clock (Sr1) at National Time Service Center (NTSC). Its systematic frequency shifts are evaluated carefully with a total relative uncertainty of 5.1E10-17. The measured absolute frequency is 429 228 004 229 872.91(18) Hz with a relative uncertainty of 4.13E10-16, with reference to the ensemble of primary and secondary frequency standards published in the Circular T bulletin by BIPM through a global navigation satellite system (GNSS) link.

18 August 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
KWKun Wu
Kun Wu
Qin WeijinQin Weijin
Qin Weijin
Daqian LyuDaqian Lyu
Daqian Lyu
WWWenjun Wu
Wenjun Wu
PWPei Wei
Pei Wei
XYXuhai Yang
Xuhai Yang
The integer precise point positioning (IPPP) technique significantly improves the accuracy of positioning and time and frequency transfer by restoring the integer nature of carrier-phase ambiguities. However, in practical applications, IPPP performance is often degraded by day-boundary discontinuities and instances of incorrect ambiguity resolution, which can compromise the reliability of time transfer. To address these challenges and enable continuous, robust, and stable IPPP time transfer, this study proposes an effective approach that utilizes narrow-lane ambiguities to absorb receiver clock jumps, combined with a robust sliding-window weighting strategy that fully exploits multi-epoch information. This method effectively mitigates day-boundary discontinuities and employs adaptive thresholding to enhance error detection and mitigate the impact of incorrect ambiguity resolution. Experimental results show that at an averaging time of 76,800 s, the frequency stabilities of GPS, Galileo, and BDS IPPP reach 4.838 × 10−16, 4.707 × 10−16, and 5.403 × 10−16, respectively. In the simulation scenario, the carrier-phase residual under the IGIII scheme is 6.7 cm, whereas the robust sliding-window weighting method yields a lower residual of 5.2 cm, demonstrating improved performance. In the zero-baseline time link, GPS IPPP achieves stability at the 10−17 level. Compared to optical fiber time transfer, the GPS IPPP solution demonstrates superior long-term performance in differential analysis. For both short- and long-baseline links, IPPP consistently outperforms the PPP float solution and IGS final products. Specifically, at an averaging time of 307,200 s, IPPP improves average frequency stability by approximately 29.3% over PPP and 32.6% over the IGS final products.