Qinfang Xu

Qinfang Xu

Auto-generated profile, based on publicly available information

Qinfang Xu

Chinese Academy of Sciences

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
QXQinfang Xu
Qinfang Xu
SWShanhe Wang
Shanhe Wang
XLXiaotong Lu
Xiaotong Lu
FGFeng Guo
Feng Guo
JXJingjing Xia
Jingjing Xia
HCHong Chang
Hong Chang
Optical clocks have been applied to the generation of time scales since they provide superb uncertainty and instability in recent years. This paper presents the simulations about the impact of the optical clock’s operational strategies on the performance of the generated time scale through two distinct steering algorithms. By post-processing the measured frequency difference between the 87Sr optical lattice clock and the hydrogen maser at the National Time Service Center, we realized an “optically steered” time scale TS(Sr), and the variation of the time difference TT(BIPM22)-TS(Sr) is 0.1 ns during the modified Julian date 59794–59819.

1 August 2026 in Metrologia
Verified
Journal Article
Open access
PDF file
FGFeng Guo
Feng Guo
YLYan-Yan Liu
Yan-Yan Liu
JXJing-Jing Xia
Jing-Jing Xia
QXQin-Fang Xu
Qin-Fang Xu
YWYe-Bing Wang
Ye-Bing Wang
HCHong Chang
Hong Chang
We present a measurement of the absolute frequency of the | 5 s 2 1 S 0 ⟩ → | 5 s 5 p 3 P 0 ⟩ transition in the SrII optical lattice clock at National Time Service Center, performed using a frequency link to International Atomic Time to provide traceability to the International System of Units second. Spanning one-year period with a total oprational duration of approximately 2700 hours, the measurement yields an absolute frequency to be 429 228 004 229 872.95(7) Hz, corresponding to a relative frequency uncertainty of 1.6 × 10 − 16 . This result is in good agreement with the 2025 Bureau of Weights and Measures recommended frequency and is anticipated to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.

6 February 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
QXQinfang Xu
Qinfang Xu
XLXiaotong Lu
Xiaotong Lu
SWShanhe Wang
Shanhe Wang
FGFeng Guo
Feng Guo
WWWenjun Wu
Wenjun Wu
HCHong Chang
Hong Chang
Owing to their exceptional performance characteristics, optical atomic clocks enable the generation of time scales that demonstrate superior accuracy and stability compared to conventional microwave clocks. This paper presents an experimental optical time scale based on the NTSC-SrⅡ optical lattice clock as the reference and a hydrogen maser as the flywheel oscillator. The time scale TS (SrⅡ), generated through post-processing analysis over a two-month period, achieves a peak-to-peak time variation of 0.39 ns relative to Coordinated Universal Time (UTC) and reaches a frequency stability of 1.94 × 10 −16 at 5 d. In addition, a physical optical time scale TS*(SrⅡ) was realized for approximately one month, and the peak-to-peak time difference is 0.3 ns compared to UTC. These results demonstrate that optical time scales maintain competitive performance even when the optical clock operates with limited and non-uniformly distributed uptime. This work constitutes an essential step toward a redefinition of the second of the International System of Units based on an optical transition.