Column percolation tests may be suitable for prediction of chemical leaching from soil and soil materials. However, compared with batch leaching tests, they are time-consuming. It is therefore important to investigate ways to shorten the tests without affecting the quality of results. In this study, we evaluate the feasibility of decreasing testing time by increasing flow rate and decreasing equilibration time compared to the conditions specified in ISO/TS 21268-3, with equilibration periods of 48h and flow rate of 12mL/h. We tested three equilibration periods (0, 12-16, and 48h) and two flow rates (12 and 36mL/h) on four different soils and compared the inorganic constituent releases. For soils A and D, we observed similar values for all conditions except for the 0h-36mL/h case. For soil B, we observed no appreciable differences between the tested conditions, while for soil C there were no consistent trends probably due to the difference in ongoing oxidation reactions between soil samples. These results suggest that column percolation tests can be shortened from 20 to 30days to 7-9days by decreasing the equilibration time to 12-16h and increasing the flow rate to 36mL/h for inorganic substances.
10 December 2014 in Journal of Nuclear Science and Technology
This paper presents a cartridge filter incorporating a nonwoven fabric impregnated with potassium zinc ferrocyanide (Zn-C) to effectively concentrate and quantify cesium dissolved in water. Experiments conducted with 137Cs in conditioned water showed that at a flow rate of 2.5 L/min the filter could absorb 97.9% of dissolved 137Cs from 20 L of water; high recovery efficiency was achieved over a pH range of 3–10. Test measurements of 137Cs concentrations using Zn-C in river water agreed with the results derived by using an evaporative concentration method (within the counting error of the detector). Using this method, the pre-concentration time of radiocesium in 20 L of fresh water can be reduced to just 8 minutes.
Soil leaching tests are commonly used to evaluate the leachability of hazardous materials, such as heavy metals, from the soil. Batch leaching tests often enhance soil colloidal mobility and may require solid-liquid separation procedures to remove excess soil particles. However, batch leaching test results depend on particles that can pass through a 0.45μm membrane filter and are influenced by test parameters such as centrifugal intensity and filtration volume per filter. To evaluate these parameters, we conducted batch leaching experiments using metal-contaminated soils and focused on the centrifugal intensity and filtration volume per filter used in solid-liquid separation methods currently employed in standard leaching tests. Our experiments showed that both centrifugal intensity and filtration volume per filter affected the reproducibility of batch leaching tests for some soil types. The results demonstrated that metal concentrations in the filtrates significantly differed according to the centrifugal intensity when it was 3000 g for 2h or less. Increased filtration volume per filter led to significant decreases in filtrate metal concentrations when filter cakes formed during filtration. Comparison of the filtration tests using 0.10 and 0.45μm membrane filters showed statistically significant differences in turbidity and metal concentration. These findings suggest that colloidal particles were not adequately removed from the extract and contributed substantially to the apparent metal concentrations in the leaching test of soil containing colloidal metals.