The modular multilevel converter (MMC) has been used in the field of HVDC transmission due to its many advantages, but its voltage imbalance problem of sub-module capacitors affects the stable operation of the system. There are two kinds of methods for solving the capacitor voltage imbalance of the MMC sub-module. The one is voltage balancing algorithm and the other one is improved topology. However, the complexity of the voltage balancing algorithm increases sharply when the number of voltage levels is high, which is not suitable for the MMC system with a high number of voltage levels. In this paper, a new topology with bidirectional voltage self-balancing capability is proposed. This topology adds the voltage balancing circuit between sub-modules on the conventional MMC topology, realizing voltage self-balancing without voltage balancing algorithm, and having a better effect of inhibition phase-to-phase circulation. The bidirectional voltage balancing capability, the voltage balancing effect and the circulation inhibition effect of the bidirectional voltage self-balancing topology are verified by MATLAB/Simulink simulation and experiment.
1 April 2023 in Protection and Control of Modern Power Systems
Hybrid high-voltage direct current (HVDC) transmission has the characteristic of long transmission distance, complex corridor environment, and rapid fault evolution of direct current (DC) lines. As high fault current can easily cause irreversible damage to power devices, rapid and reliable line protection and isolation are necessary to improve the security and reliability of hybrid HVDC transmission system. To address such requirement, this paper proposes a single-ended protection method based on transient voltage frequency band characteristics. First, the frequency characteristics of the smoothing reactor, DC filter, and DC line are analyzed, and the characteristic frequency band is defined. A fault criterion is then constructed based on the voltage characteristic frequency band energy, and faulty pole selection is performed according to the fault voltage characteristic frequency band energy ratio. The proposed protection method is verified by simulation, and the results show that it can rapidly and reliably identify internal and external faults, accurately select faulty poles without data communication synchronization, and has good fault-resistance and anti-interference performance.
27 March 2023 in IEEE Transactions on Industrial Electronics
In the field of hybrid multiterminal high-voltage direct current (HVdc) transmission, an inevitable problem is the short availability of fault information. Namely, only 1-ms complete fault information can be used to identify faults. To overcome this limitation, this study introduces the concept of instantaneous boundary impedance and proposes a dc line protection method. First, a dc transmission line is divided into three types of zones, namely, internal, forward-external, and backward-external zones. Then, the instantaneous boundary impedance is analyzed and compared under normal operation and different types of faults. The results indicate that under normal operation, the instantaneous boundary impedance is zero; under a dc line fault, the instantaneous boundary impedance is less than zero; and finally, under an external fault, the instantaneous boundary impedance is greater than zero. The proposed principle is validated using the Wudongde line-commuted converter–voltage-source converter three-terminal hybrid HVdc real-time digital simulation test system. The experimental results demonstrate that the proposed protection method is effective under different types, locations, and impedances of faults and signal-to-noise ratios within a period of 1 ms. Compared to the existing methods, the proposed protection method can achieve better performance in withstanding fault impedance (600 Ω) and has better robustness against noise interference (10 dB).
15 April 2024 in IEEE Transactions on Industrial Electronics
This article considers the problems of high difficulty in fault analysis of direct current (dc) line in a voltage source converter (VSC)–high-voltage direct current (HVdc) outgoing system from wind farms and the poor adaptability of traditional protection principle. To solve these problems, this article proposes single-ended protection of the VSC-HVdc outgoing line based on the time-domain weighted optimization (TDWO) of a fault backward traveling wave (BTW). The analysis of the propagation process of the internal fault (IF) and external fault (EF) voltage BTW and the attenuation characteristics of the dc line and boundary shows that the voltage BTW measured by the protection element decreases significantly under IF. When an EF occurs, the variation range of the voltage measured by the protection element is small, and the higher the frequency is, the more significant the difference between them is. The fault data are optimized by using the time-domain weighted coefficient, and the fault distinction between the IF and EF is expanded. In addition, the fault identification criterion is constructed according to the time-domain weighted coefficient. The proposed protection method is verified by experiments using a renewable energy grid-connected system constructed on a real-time digital simulation (RTDS) platform. The experimental results show that the proposed protection method can identify faults rapidly with a small amount of calculation and realize the full-line action with high speed, reliability, and sensitivity. The maximum achievable sampling rate for safeguarding equipment is up to 50 kHz; the proposed method, with a sampling rate of 20 kHz, has an application value in practical engineering.
1 November 2023 in IEEE Transactions on Industrial Electronics
The environment of ultrahigh-voltage long-distance hybrid cascading overhead dc transmission lines is complex, and the line fault probability is high. The transmission time of the conventional pilot protection via optical fiber communication is long, causing delays in the implementation of protective actions and seriously affecting the protection scheme's responsiveness. This article, an accelerated backup protection suitable for long-distance dc transmission lines is proposed. Using the Chebyshev digital filter to extract the high-frequency components of the fault voltage, the protection scheme uses the ratio of the components on both sides of the electrical boundary of the dc transmission line to formulate a directional element. Based on the directional elements on both sides of the line, a blocking-type pilot directional protection is established. Experiments show that the backup protection scheme can reduce the protection time compared with the traditional pilot protection, and also has the ability of accurate fault pole selection. The protection principle and method have strong robustness to transition resistance and noise.
11 September 2023 in IEEE Transactions on Industrial Electronics
Traditional high voltage direct current protection methods based on a traveling wave have limited identification capability for near-end, far-end, and high-impedance system faults and cannot meet the reliability requirements for system protection. To address these shortcomings, this article proposes a pilot protection method based on the high-order difference transient voltage. First, the propagation of fault traveling waves is analyzed, and it is studied how the inhibition of high-frequency (HF) components by boundary components causes differences in the HF components between the fault voltages during internal and external faults. Next, the amplitude-frequency characteristics of a high-order difference are analyzed, and it is shown that this difference exhibits excellent high-pass filter capabilities. Namely, by applying the high-order difference to the fault voltage on both sides of the boundary components, the HF differences between the two voltages can be significantly amplified. Then, the start-up element and the fault direction identification elements are constructed, and a complete protection method is developed. Finally, a hybrid multiterminal direct current system is established using a real-time digital simulator, and numerous experiments are conducted to verify the proposed method. The results show that the proposed protection method can rapidly identify both internal and external faults with high reliability. In addition, it is demonstrated that the proposed method exhibits strong high-impedance fault resistance, is insensitive to noise and fault location, and does not have high requirements for time synchronization and communication, making it easy to implement in engineering applications.