Meihong Zhang

Dr. Meihong Zhang

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MZMeihong Zhang
Meihong Zhang
BQBocheng Qian
Bocheng Qian
JGJianming Gao
Jianming Gao
SZShaokai Zhao
Shaokai Zhao
YCYibo Cui
Yibo Cui
EYErWei Yin
ErWei Yin
As brain–computer interface (BCI) technology continues to advance, research on human brain function has gradually transitioned from theoretical investigation to practical engineering applications. To support EEG signal acquisition in a variety of real-world scenarios, BCI electrode systems must demonstrate a balanced combination of electrical performance, wearing comfort, and portability. Dry electrodes have emerged as a promising alternative for EEG acquisition due to their ability to operate without conductive gel or complex skin preparation. This paper reviews the latest progress in dry electrode EEG systems, summarizing key achievements in hardware design with a focus on structural innovation and material development. It also examines application advances in several representative BCI domains, including emotion recognition, fatigue and drowsiness detection, motor imagery, and steady-state visual evoked potentials, while analyzing system-level performance. Finally, the paper critically assesses existing challenges and identifies critical future research priorities. Key recommendations include developing a standardized evaluation framework to bolster research reliability, enhancing generalization performance, and fostering coordinated hardware-algorithm optimization. These steps are crucial for advancing the practical implementation of these technologies across diverse scenarios. With this survey, we aim to offer a comprehensive reference and roadmap for researchers engaged in the development and implementation of next-generation dry electrode EEG-based BCI systems.

1 January 2015 in Journal of Propulsion and Power
Verified
Journal Article
Closed access
YZYufei Zhang
Yufei Zhang
HCHaixin Chen
Haixin Chen
Miao ZhangMiao Zhang
Miao Zhang
MZMeihong Zhang
Meihong Zhang
ZLZhao Li
Zhao Li
SFSong Fu
Song Fu
This paper describes the numerical investigation of convergent conical nozzles done in the AIAA Propulsion Aerodynamic Workshop number one. Axisymmetric, three-dimensional, and unsteady computations were conducted for three main test cases. These test cases were 1) axisymmetric convergent conical nozzles of 15, 25, and 40 deg half-angle as well as a reference nozzle; 2) the 25 deg half-angle nozzle with a splitter plate inserted in its plane of symmetry; and 3) the vortex shedding observed at the base of the splitter plate. The effects of base drag and freestream Mach number on calculated velocity coefficient were analyzed. The discharge coefficients and velocity coefficients determined from the axisymmetric solutions matched the experimental data well. The wall Mach numbers and sonic line positions were also well predicted. In the axisymmetric computations, the shock position was well captured by the fine grid. However, when the nozzle pressure ratio was high, the three-dimensional Reynolds-averaged Navi...

31 October 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MZMeihong Zhang
Meihong Zhang
ZLZhiguo Luo
Zhiguo Luo
LXLiang Xie
Liang Xie
TLTiejun Liu
Tiejun Liu
YYYe Yan
Ye Yan
EYErWei Yin
ErWei Yin
Nowadays, how to estimate vigilance with higher accuracy has become a hot field of research direction. Although the increasing available modalities opens the door for amazing new possibilities to achieve good performance, the uncertain cross-modal interaction still poses a real challenge to the multimodal fusion. In this paper, a cross-modality alignment method has been proposed based on the contrastive learning for extracting shared but not the same information among modalities. The contrastive learning is adopted to minimize the intermodal differences by maximizing the similarity of semantic representation of modalities. Applying our proposed modeling framework, we evaluated our approach on SEED-VIG dataset consisting of EEG and EOG signals. Experiments showed that our study achieved state-of-the-art multimodal vigilance estimation performance both in intra-subject and inter-subject situations, the average of RMSE/CORR were improved to 0.092/0.893 and 0.144/0.887, respectively. In addition, analysis on the frequency bands showed that theta and alpha activities contain valuable information for vigilance estimation, and the correlation between them and PERCLOS can be significantly improved by contrastive learning. We argue that the proposed method in the inter-subject case could offer the possibility of reducing the high-cost of data annotation, and further analysis may provide an idea for the application of multimodal vigilance regression.

6 April 2025
Verified
Conference Paper
Closed access
MZMeihong Zhang
Meihong Zhang
SZShaokai Zhao
Shaokai Zhao
ZLZhiguo Luo
Zhiguo Luo
LXLiang Xie
Liang Xie
TLTiejun Liu
Tiejun Liu
EYErwei Yin
Erwei Yin
The use of dry electrode electroencephalography (EEG) systems holds significant importance in advancing the everyday application of emotion recognition. However, adapting it to real-world applications faces unique challenges due to low signal-to-noise ratios and unreliable emotion labels. To address these challenges, we propose a Cross-Device Representation Consistency (CDRC) pre-training paradigm for dry EEG emotion recognition, where the self-supervised signal is provided by the distance between representations embedded in wet and dry EEG components and trained via contrastive estimation. Specifically, we employ a dual-branch embedding prediction task coupled with contrastive feature alignment module to extract robust and distinctive features from dry electrode EEG signals. We evaluate our model on an available emotional dataset PaDWEED, extensive experiments demonstrate that CDRC performs comparably to fully supervised training and achieves state-of-the-art results compared to several self-supervised approaches. Moreover, the remarkable performance on subject-independent tasks highlights its effectiveness in addressing and mitigating subject variability.

1 May 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MZMeihong Zhang
Meihong Zhang
SZShaokai Zhao
Shaokai Zhao
LXLiang Xie
Liang Xie
TLTiejun Liu
Tiejun Liu
DYDezhong Yao
Dezhong Yao
EYErWei Yin
ErWei Yin
Electroencephalography (EEG) has emerged as a powerful tool for modeling human brain states. However, the widespread adoption of EEG-based recognition systems is hindered by low signal-to-noise ratios and the scarcity of labeled data. While existing studies often tackle these challenges in isolation, we propose a novel Cross-Device Representation Consistency (CDRC) pretraining paradigm that addresses both issues simultaneously. CDRC leverages self-supervised signals derived from representation distances and is trained through contrastive estimation. Specifically, our approach employs a transformer based dual-branch single-view embedding prediction task, combining with a contrastive feature alignment module to extract robust and discriminative representations. We first evaluate the CDRC model on a low signal-to-noise ratio emotion classification task involving wearable dry electrodes. Furthermore, we extend CDRC to a multimodal fusion setting to address a cross-device vigilance regression task involving heterogeneous physiological modalities. Extensive experiments on the PaDWEED and SEED-VIG datasets demonstrate that CDRC achieves performance comparable to fully supervised methods and reaches the stat-of-the-art results of existing self-supervised methods, setting a new benchmark in this field. Notably, its strong performance on subject-independent tasks highlights its effectiveness in mitigating subject variability. These results underscore the potential of CDRC to significantly enhance the practicality and scalability of EEG-based recognition systems, marking a meaningful step toward real-world brain-computer interfaces.

6 September 2024 in arXiv
Verified
Preprint
Open access
PDF file
MZMeihong Zhang
Meihong Zhang
SZShaokai Zhao
Shaokai Zhao
SWshuai wang
shuai wang
ZLZhiguo Luo
Zhiguo Luo
LXLiang Xie
Liang Xie
EYErWei Yin
ErWei Yin
EEG signal is important for brain-computer interfaces (BCI). Nevertheless, existing dry and wet electrodes are difficult to balance between high signal-to-noise ratio and portability in EEG recording, which limits the practical use of BCI. In this study, we propose a Denoising Encoder via Contrastive Alignment Network (DECAN) for dry electrode EEG, under the assumption of the EEG representation consistency between wet and dry electrodes during the same task. Specifically, DECAN employs two parameter-sharing deep neural networks to extract task-relevant representations of dry and wet electrode signals, and then integrates a representation-consistent contrastive loss to minimize the distance between representations from the same timestamp and category but different devices. To assess the feasibility of our approach, we construct an emotion dataset consisting of paired dry and wet electrode EEG signals from 16 subjects with 5 emotions, named PaDWEED. Results on PaDWEED show that DECAN achieves an average accuracy increase of 6.94$\%$ comparing to state-of-the art performance in emotion recognition of dry electrodes. Ablation studies demonstrate a decrease in inter-class aliasing along with noteworthy accuracy enhancements in the delta and beta frequency bands. Moreover, an inter-subject feature alignment can obtain an accuracy improvement of 5.99$\%$ and 5.14$\%$ in intra- and inter-dataset scenarios, respectively. Our proposed method may open up new avenues for BCI with dry electrodes. PaDWEED dataset used in this study is freely available at https://huggingface.co/datasets/peiyu999/PaDWEED.