The growing challenges in healthcare services, such as hospital congestion and a persistent shortage of medical personnel, significantly impede effective service delivery. This particularly presents significant challenges for the continuous monitoring of patients with chronic diseases. In comparison, Internet of Things (IoT) based telemonitoring systems offer a promising solution to alleviate these challenges. However, transmitting sensitive and confidential patient health data requires a strong focus on end-to-end security. This includes securing sensitive data within the patient’s home network, during internet transmission, at the endpoint system, and managing sensitive data. In this study, we propose a secure and scalable architecture for a remote health monitoring system that integrates telemedicine technology with the IoT. The proposed solution included a portable remote health monitoring device, an IoT Gateway appliance (IoT GW) in the patient’s home, and an IoT Application Gateway Endpoint (App GW Endpoint) on a cloud infrastructure. A secure communication channel was established by implementing a multi-layered security protocol stack that uses HTTPS over Quick UDP Internet Connection (QUIC), with a focus on optimal security and compatibility, prioritizing cipher suites for data confidentiality and device authentication. The cloud architecture is designed based on the Well-Architected Framework principles to ensure security, high availability, and scalability. Our study shows that storing patient health information is reliable and efficient. Furthermore, the results for processing and transmission times clearly demonstrate that the additional encryption mechanisms have a negligible effect on data transmission latency, while significantly improving security.
1 January 2017 in IEICE Transactions on Communications
This paper presents a preliminary technical feasibility study of a landmark-based motion analysis system designed for potential future application in home-based rehabilitation monitoring for frozen shoulder (adhesive capsulitis), developed using computer vision (CV) and human–computer interaction (HCI) principles. The proposed system utilizes real-time body landmark detection to quantify shoulder joint kinematics and provide rule-based automated feedback on exercise execution. The system combines automated and manual components: while shoulder angle assessment, cosine similarity analysis, and keyframe matching are automated, manual researcher input is required to define keyframes corresponding to movement states (start, midpoint, peak) for each therapeutic pose. The CV-driven perception is translated into HCI output, including quantitative movement scores and rule-based feedback indicators, demonstrating the technical potential for objective evaluation of rehabilitation exercise execution without specialized wearable sensors. Technical validation was conducted with 14 healthy volunteers (not frozen shoulder patients) executing standardized shoulder rehabilitation activities, demonstrating shoulder angle measurement with an overall mean absolute error (MAE) of 7.03° against general goniometry and 6.61° against clinical goniometry (RMSE: 8.50° and 8.79°, respectively). Movement similarity classification achieved F1-scores ranging from 0.870 (flexion) to 1.0 (internal rotation) when compared against expert evaluation, though these results are based on a controlled and largely imbalanced dataset with limited incorrect movement examples. The system additionally incorporates a facial expression recognition (FER) module, previously developed and validated in the authors’ prior work, as a supplementary component to support future integration of pain monitoring; this module was not independently validated in the present study. This preliminary technical feasibility study contributes to rehabilitation engineering by demonstrating the potential of semi-automated CV-based motion analysis and rule-based HCI feedback for shoulder movement assessment. The findings indicate technical feasibility for future investigation in home-based exercise monitoring; however, clinical utility cannot be claimed at this stage, as validation with actual frozen shoulder patient cohorts is required.
This paper presents an analytical evaluation of three strategies designed to minimize service disruption during handovers in Software-Defined Networking (SDN)-based connected car networks: SDN Mobility with a Caching Policy, cache-miss Content Delivery Network (CDN), and cache-hit CDN. The performance trade-offs inherent in each approach have been quantitatively compared, and their multi-faceted performances have been analyzed. The evaluation includes a range of Session-to-Mobility Ratios (SMR), sensitivities of core network latency and L2 handover delays, and a realistic assessment of CDN effectiveness as a function of its cache-hit ratio. Our analysis conclusively shows that the availability of content on the network edge is the key factor for ensuring seamless connectivity. The study also identifies a quantitative crossover point 70% cache-hit ratio, where the proactive CDN’s performance surpasses that of reactive Caching Policy, establishing a clear target for predictive algorithms. Results confirm that while the cache-hit strategy offers the lowest disruption, the high data plane latency of a cache-miss 100 ms delay makes it unsuitable for vehicular applications, and the Caching Policy is limited by a 30 ms control plane overhead. This paper provides a robust framework for future vehicular network designs that proactive edge-based architectures are critical for stringent connectivity requirements.