Zhou Chengan

Mr. Zhou Chengan

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
BDBowen Deng
Bowen Deng
Li-Feng Zhang 张立峰Li-Feng Zhang 张立峰
Li-Feng Zhang 张立峰
SWShengze Wu
Shengze Wu
Haibo JiangHaibo Jiang
Haibo Jiang
YTYueqiang Tian
Yueqiang Tian
ZCZhou Chengan
Zhou Chengan
The shear stirrups and bend-up reinforcement in ultra-high-performance concrete (UHPC) beams could potentially be excluded due to the superior mechanical properties of UHPC. This paper reports the new findings of an experimental research into the factors that influence the shear behavior of non-stirrup UHPC beams. Fourteen beams were tested in shear, comprising twelve non-stirrup UHPC beams and two normal concrete (NC) beams reinforced with stirrups. The test variables included the steel fiber volume content (2.0%, 1.5%, and 0%), the shear span-to-effective-depth ratio (1.2, 1.8, 2.0, and 3.1), beam width (150 mm and 200 mm), and beam height (300 mm, 350 mm, and 400 mm). The results demonstrated that the steel fiber volume content had a significant influence on the shear behavior of the non-stirrup UHPC beams. The failure modes of the beams without steel fibers were typically brittle, whereas those reinforced with steel fibers exhibited ductile failure. The shear resistance of the beams could be significantly enhanced by the addition of steel fibers in the concrete mix. Furthermore, the post-cracking load-bearing performance of the beams could also be markedly improved by the addition of steel fibers. In addition, the shear span-to-effective-depth ratio had a considerable impact on the failure mode and the ultimate shear strength of the tested beams. The contribution of steel fibers to the shear capacity of the UHPC beams was observed to increase as the shear span-to-effective-depth ratio increased. The French standard formulae tended to overestimate the contribution of steel fibers, and the calculation results were found to be more accurate for UHPC beams with a moderate shear span-to-effective-depth ratio (around 2.0). Moreover, the French standard formulae demonstrated greater accuracy at a larger beam height for calculating the contribution of UHPC matrix.

28 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
ZCZhou Chengan
Zhou Chengan
SWShengze Wu
Shengze Wu
Kaisheng WuKaisheng Wu
Kaisheng Wu
FMFan Mo
Fan Mo
Haibo JiangHaibo Jiang
Haibo Jiang
JFJunfa Fang
Junfa Fang
Ultra-high-performance concrete (UHPC) exhibits significantly superior compressive and tensile properties compared to conventional concrete, demonstrating substantial application potential in bridge engineering. This study conducted full-scale bending tests on a 30 m prestressed UHPC-NC composite box girder within an actual engineering context. The testing flexural capacity Mt=34,469.2 kN·m exceeded the design requirement Md=18,138.0 kN·m, with Mt/Md=1.90. Finite element modeling (FEM) was employed to analyze and predict experimental outcomes, revealing a simulated flexural capacity of approximately 37,597.1 kN·m. The finite element models further explored failure mode transitions governed by the loading position while the concentrated load-to-support distance exceeds 9.62 m (shear span to effective depth ratio λ = 6.3), and the box girder fails in flexure; while less than 9.62 m, the box girder fails in shear. The flexural capacity of the test girder was also estimated using Response-2000 software and the recommended formulas from the Chinese code T/CCES 27-2021 (Technical specification for ultra-high-performance concrete girder bridge). The Response-2000 software yielded a flexural capacity estimate of Mr=30,816.1 kN·m. The technical specification provided two estimating results: (with safety factors) Mu1=25,414.4 kN·m and (without safety factors)  Mu2=33,810.9 kN·m. All estimated values of Response-2000 and Chinese code were rationally conservative (Mr, Mu1, Mu2<Mt). Comparative analysis demonstrates that Abaqus FEM accurately simulates the flexural behavior of the prestressed UHPC-NC composite box girders. Both Response-2000 calculations and the Chinese code T/CCES 27-2021 provide critical references for similar applications of prestressed UHPC-NC composite box girders.

15 April 2025 in Buildings
Verified
Journal Article
Open access
PDF file
GMGongyong Mei
Gongyong Mei
ZCZhou Chengan
Zhou Chengan
SWShengze Wu
Shengze Wu
Li-Feng Zhang 张立峰Li-Feng Zhang 张立峰
Li-Feng Zhang 张立峰
Jie XiaoJie Xiao
Jie Xiao
Haibo JiangHaibo Jiang
Haibo Jiang
Additional steel supporting joists (ASSJs) can effectively enhance the anti-overturning capacity of the existing solo-column concrete pier (SCP) bridges. Although the interface consists of bolt connections between steel and concrete is the crucial load-transmitting portion, the design of the interface between the ASSJ and SCP still mainly relies on practical experiences. In an actual bridge rehabilitation project with ASSJs in China, a novel connection comprising large-diameter bolts and an epoxy resin layer was adopted to overcome the shortcomings of the initial design. In this study, connections composited with large-diameter bolts and different interfacial treatments were investigated. Four push-out tests on the interfacial shear performance of steel–concrete connections were carried out. The experimental parameters encompassed the interface treatment method (barely roughened surface, smearing epoxy resin, and filling epoxy mortar) and the number of bolts (single row and double rows). The failure modes were unveiled. According to the experimental results, the interfacial treatment method with filling epoxy mortar could uniformly transfer stress between concrete and steel and improve the shear stiffness and shear resistance of the steel–concrete connections. Compared with specimens with barely roughened interfaces, epoxy mortar and epoxy resin employed at the steel–concrete interface can increase the shear-bearing capacity of connections by approximately 47.71% and 43.46%, respectively. However, the interfacial treatment method with smearing epoxy resin resulted in excessive stiffness of the shear members and brittle failure mode. As the number of the bolts increased from a single row to a double row, the shear-bearing capacity of a single bolt in the specimen exhibited approximately an 8% reduction. In addition, by comparing several theoretical formulae with experimental results, the accurate formula for predicting the shear-bearing capacity of bolts was recommended. Furthermore, the load-bearing capacity of an ASSJ in the actual engineering rehabilitation was verified by the recommended formula GB50017-2017, which was found to accurately predict the shear-bearing capacity of large-diameter bolt connectors with an epoxy mortar layer.

1 September 2025 in Buildings
Verified
Journal Article
Open access
PDF file
SWShengze Wu
Shengze Wu
ZCZhou Chengan
Zhou Chengan
FMFan Mo
Fan Mo
Li-Feng Zhang 张立峰Li-Feng Zhang 张立峰
Li-Feng Zhang 张立峰
Haibo JiangHaibo Jiang
Haibo Jiang
JFJunfa Fang
Junfa Fang
Ultra-High-Performance Concrete (UHPC) is a game-changing, innovative material with the merits of exceptional tensile strength, making it suitable for stirrup-free UHPC beams. In this study, two 4.0 m-long large-scale stirrup-free I-shaped UHPC beams were experimentally explored in bending tests and shear tests. Cracking patterns, failure modes, and ultimate load-bearing capacity were obtained. Experimental findings revealed that the shear capacity of the stirrup-free I-shaped UHPC beams with a web thickness of merely 50.0 mm reached more than 20.0 MPa and demonstrated excellent post-cracking shear behavior. Finite element models were established and verified with experimental results to investigate the shear behaviors of stirrup-free I-shaped UHPC beams, considering the parameters of shear span-depth ratio and longitudinal reinforcement strength. The results demonstrated that as the shear span-depth ratio increases, the shear capacity of UHPC beams exhibits a declining trend, accompanied by increased mid-span deflection and a degradation in stiffness. French code and PCI report were suggested for design purposes, due to rationally conservative prediction and explicit physical indication.