Chao-Sung Lai

Prof. Chao-Sung Lai

Chang Gung University
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2012 in Nano Letters
Verified
Journal Article
Closed access
KLKeng-Ku Liu
Keng-Ku Liu
WZWenjing Zhang
Wenjing Zhang
YLYi-Hsien Lee
Yi-Hsien Lee
YLYu-Chuan Lin
Yu-Chuan Lin
MCMu-Tung Chang
Mu-Tung Chang
LLLain-Jong Li
Lain-Jong Li

28 May 2020 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
CYChia-Ming Yang
Chia-Ming Yang
TCTsung‐Cheng Chen
Tsung‐Cheng Chen
DVDharmendra Verma
Dharmendra Verma
LLLain‐Jong Li
Lain‐Jong Li
BLBo Liu
Bo Liu
Chao-Sung LaiChao-Sung Lai
Chao-Sung Lai

20 July 2023 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
JFJui-Han Fu
Jui-Han Fu
JMJiacheng Min
Jiacheng Min
CCChe-Kang Chang
Che-Kang Chang
CTChien-Chih Tseng
Chien-Chih Tseng
QWQingxiao Wang
Qingxiao Wang
VTVincent Tung
Vincent Tung

31 July 2014 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KHKuan-I Ho
Kuan-I Ho
CHChi-Hsien Huang
Chi-Hsien Huang
JLJia-Hong Liao
Jia-Hong Liao
WZWenjing Zhang
Wenjing Zhang
LLLain-Jong Li
Lain-Jong Li
CSChing Yuan Su
Ching Yuan Su
There is broad interest in surface functionalization of 2D materials and its related applications. In this work, we present a novel graphene layer transistor fabricated by introducing fluorinated graphene (fluorographene), one of the thinnest 2D insulator, as the gate dielectric material. For the first time, the dielectric properties of fluorographene, including its dielectric constant, frequency dispersion, breakdown electric field and thermal stability, were comprehensively investigated. We found that fluorographene with extremely thin thickness (5 nm) can sustain high resistance at temperature up to 400°C. The measured breakdown electric field is higher than 10 MV cm−1, which is the heightest value for dielectric materials in this thickness. Moreover, a proof-of-concept methodology, one-step fluorination of 10-layered graphene, is readily to obtain the fluorographene/graphene heterostructures, where the top-gated transistor based on this structure exhibits an average carrier mobility above 760 cm2/Vs, higher than that obtained when SiO2 and GO were used as gate dielectric materials. The demonstrated fluorographene shows excellent dielectric properties with fast and scalable processing, providing a universal applications for the integration of versatile nano-electronic devices.

1 December 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ADAtanu Das
Atanu Das
DKDanny Hsu Ko
Danny Hsu Ko
CCChia-Hsin Chen
Chia-Hsin Chen
LCLiann-Be Chang
Liann-Be Chang
Chao-Sung LaiChao-Sung Lai
Chao-Sung Lai
RLRay-Ming Lin
Ray-Ming Lin

31 October 2020 in Biomedicines
Verified
Journal Article
Open access
PDF file
MCMing-Jen Chan
Ming-Jen Chan
YLYi-Jung Li
Yi-Jung Li
CWChao-Ching Wu
Chao-Ching Wu
YLYu-Chen Lee
Yu-Chen Lee
HZHsiao-Wen Zan
Hsiao-Wen Zan
YTYa-Chung Tian
Ya-Chung Tian
Chronic kidney disease (CKD) is a public health problem and its prevalence has increased worldwide; patients are commonly unaware of the condition. The present study aimed to investigate whether exhaled breath ammonia via vertical-channel organic semiconductor (V-OSC) sensor measurement could be used for rapid CKD screening. We enrolled 121 CKD stage 1–5 patients, including 19 stage 1 patients, 26 stage 2 patients, 38 stage 3 patients, 21 stage 4 patients, and 17 stage 5 patients, from July 2019 to January 2020. Demographic and laboratory data were recorded. The exhaled ammonia was collected and rapidly measured by the V-OSC sensor to correlate with kidney function. Results showed no significant difference in age, sex, body weight, hemoglobin, albumin level, and comorbidities in different CKD stage patients. Correlation analysis demonstrated a good correlation between breath ammonia and blood urea nitrogen levels, serum creatinine levels, and estimated glomerular filtration rate (eGFR). Breath ammonia concentration was significantly elevated with increased CKD stage compared with the previous stage (CKD stage 1/2/3/4/5: 636 ± 94; 1020 ± 120; 1943 ± 326; 4421 ± 1042; 12781 ± 1807 ppb, p < 0.05). The receiver operating characteristic curve analysis showed an area under the curve (AUC) of 0.835 (p < 0.0001) for distinguishing CKD stage 1 from other CKD stages at 974 ppb (sensitivity, 69%; specificity, 95%). The AUC was 0.831 (p < 0.0001) for distinguishing between patients with/without eGFR < 60 mL/min/1.73 m2 (cutoff 1187 ppb: sensitivity, 71%; specificity, 78%). At 886 ppb, the sensitivity increased to 80% but the specificity decreased to 69%. This value is suitable for kidney function screening. Breath ammonia detection with V-OSC is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy.