Marcel Bojan

Mr. Marcel Bojan

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
DCDiana Cerghizan
Diana Cerghizan
KJKinga Mária Jánosi
Kinga Mária Jánosi
AFAlexandra Farcas
Alexandra Farcas
MBMarcel Bojan
Marcel Bojan
MMMircea Muntean
Mircea Muntean
GMGyula Marada
Gyula Marada
Background/Objectives: Accurate full-arch impressions are crucial for predictable prosthodontic outcomes. While intraoral scanners (IOSs) are increasingly adopted, evidence comparing their accuracy with conventional analog impressions across full mandibular arches—particularly under both laboratory and clinical conditions using an objective intraoral reference—is limited. Our study aims to evaluate the in vitro and in vivo accuracy of digital impressions compared to conventional methods in full-arch scans using an intraoral reference tool. Methods: In this study, a custom stainless steel transfer aid carrying four 5 mm steel spheres in a trapezoidal configuration, provided with known reference distances, was used. Ten mandibular Frasaco models (in vitro) and ten healthy young adults (18–30 yrs) with intact lower arches (in vivo) received the bonded spheres. Six inter-sphere distances were defined: intermolar (BL-BR), interpremolar (FL-FR), diagonals (BL-FR, FL-BR), and lateral spans (BL-FL, BR-FR). Each arch underwent a digital scan (Medit i700) and a conventional monophase PVS impression, which was poured in Type IV stone and digitized (GOM Scan 1). The inter-sphere linear distances were measured in GOM Inspect, and trueness (deviation from reference) and precision (SD) were calculated. Data normality and homogeneity were verified; parametric t-tests and one-sample tests (α = 0.05) assessed differences between workflows and against reference values. Results: In vitro, analog impressions closely matched reference distances, with only the long-span BL-BR showing minor deviation (0.053 mm, p < 0.001). Digital scans showed significantly greater deviations across all spans (max 0.117 mm), particularly over long distances. In vivo, both workflows demonstrated comparable accuracy: only BL-BR (analog) and BR-FR (digital) differed significantly from the reference, and all AMEs remained within clinical thresholds (≤0.10 mm), except for BL-BR and BL-FL spans. ICC values ranged from moderate to high. Direct paired comparisons revealed statistically equivalent performance across most spans. Conclusions: Analog impressions outperformed digital scans in vitro, particularly across longer spans, confirming their superior dimensional fidelity under controlled conditions. However, in vivo, both workflows delivered statistically comparable and clinically acceptable accuracy. These findings suggest that while analog impressions remain the gold standard for precision-demanding contexts, modern intraoral scanners—when used correctly—can offer reliable full-arch mandibular impressions. The four-sphere reference system proved valuable for objective, anatomy-independent measurement.

4 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
CTCarmen Tripon
Carmen Tripon
M S SwapnaM S Swapna
M S Swapna
Nicoleta CobîrzanNicoleta Cobîrzan
Nicoleta Cobîrzan
Dorota KorteDorota Korte
Dorota Korte
RGRobert Gutt
Robert Gutt
DDDorin Nicolae Dadarlat
Dorin Nicolae Dadarlat
A new photopyroelectric detection configuration is proposed in order to measure the thermal effusivity of porous solids. Compared with the previously reported detection scheme this configuration makes use of a transparent window in front of the pyroelectric sensor. In such a way, the heat losses by convection at the sensor’s irradiated surface are eliminated, and consequently, the conduction remains the only process responsible for the heat propagation in the whole detection cell. In the paper, the mathematical model for this new configuration is developed, with the main conclusion that the sample’s thermal effusivity can be finally obtained via a fitting procedure with only two fitting parameters (instead of three as previously reported); in such a way, the possible degeneracy of the results is eliminated. The suitability of the method is demonstrated with application on some porous building materials and cellulose-based pressed powders.

26 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
M S SwapnaM S Swapna
M S Swapna
CTCarmen Tripon
Carmen Tripon
RGRobert Gutt
Robert Gutt
AFAlexandra Farcas
Alexandra Farcas
MBMarcel Bojan
Marcel Bojan
DDDorin Nicolae Dadarlat
Dorin Nicolae Dadarlat
A general theory of a photopyroelectric (PPE) configuration, based on an opaque sample and transparent pyroelectric sensor, backing and coupling fluids is developed. A combined back-front detection investigation, based on a frequency scan of the phase of the PPE signals, followed by a self-normalization of the phases’ behavior, leads to the possibility of simultaneously measuring both thermal effusivity and diffusivity of a solid sample. A particular case of this configuration, with no coupling fluid at the sample/backing interface and air instead of coupling fluid at the sample/sensor interface (non-contact method) is suitable for simultaneous measurement ofboth thermal diffusivity and effusivity (in fact complete thermal characterization) of porous solids. Compared with the already proposed configurations for investigations of porous materials, this novel configuration makes use of a fitting procedure with only one fitting parameter, in order to guarantee the uniqueness of the solution. The porous solids belong to a class of materials which are by far not easy to be investigated using PPE. To the best of our knowledge, porous materials represent the only type of compounds, belonging to condensed matter, which were not taken into consideration (until recently) as potential samples for PPE calorimetric investigations. Consequently, the method proposed in this paper complete the area of applications of the PPE method. Applications on some porous building materials and cellulose-based samples validate the theory.