Mircea Muntean

Mr. Mircea Muntean

Technical University of Cluj-Napoca, Cluj-Napoca, Cluj, Romania

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AVAlexandru Vlasa
Alexandru Vlasa
VBVlad Bocanet
Vlad Bocanet
MMMircea Muntean
Mircea Muntean
ABAnamaria Bud
Anamaria Bud
BDBogdan Radu Dragomir
Bogdan Radu Dragomir
EBEugen Bud
Eugen Bud
Additive manufacturing is a technology that has many uses across a variety of fields. Its usage spans many fields, including the fields of art, design, architecture, engineering and medicine, including dentistry. The study aims to evaluate and compare the accuracy of three-dimensional printed dental models based on ethylene di-methacrylate using the SLA and DLP techniques. For evaluation, a reference model containing 16 maxillary permanent molars was chosen. An ATOS Capsule 3D scanner was used to scan the reference model. Using a photo-cured liquid resin, eight three-dimensional printed models were obtained using the reference model as benchmark. Four of the models (A1–A4) were obtained using SLA printing technology and four models (B1–B4) were manufactured using DLP printing technology. A standard best fit method was used to pre-align the reference and the printed model surfaces. The height of the teeth, and the mesial–distal and buccal–lingual distances were analyzed. The assessment of the two manufacturing methods was achieved by using non-parametric tests to compare the mean ranks for the assessed features. The results show that models obtained through DLP had a higher precision but also a higher bias. Both methods still are within the required accuracy range for dental models.


19 August 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
DCDiana Cerghizan
Diana Cerghizan
KJKinga Mária Jánosi
Kinga Mária Jánosi
AFAlexandra Farcas
Alexandra Farcas
MBMarcel Bojan
Marcel Bojan
MMMircea Muntean
Mircea Muntean
GMGyula Marada
Gyula Marada
Background/Objectives: Accurate full-arch impressions are crucial for predictable prosthodontic outcomes. While intraoral scanners (IOSs) are increasingly adopted, evidence comparing their accuracy with conventional analog impressions across full mandibular arches—particularly under both laboratory and clinical conditions using an objective intraoral reference—is limited. Our study aims to evaluate the in vitro and in vivo accuracy of digital impressions compared to conventional methods in full-arch scans using an intraoral reference tool. Methods: In this study, a custom stainless steel transfer aid carrying four 5 mm steel spheres in a trapezoidal configuration, provided with known reference distances, was used. Ten mandibular Frasaco models (in vitro) and ten healthy young adults (18–30 yrs) with intact lower arches (in vivo) received the bonded spheres. Six inter-sphere distances were defined: intermolar (BL-BR), interpremolar (FL-FR), diagonals (BL-FR, FL-BR), and lateral spans (BL-FL, BR-FR). Each arch underwent a digital scan (Medit i700) and a conventional monophase PVS impression, which was poured in Type IV stone and digitized (GOM Scan 1). The inter-sphere linear distances were measured in GOM Inspect, and trueness (deviation from reference) and precision (SD) were calculated. Data normality and homogeneity were verified; parametric t-tests and one-sample tests (α = 0.05) assessed differences between workflows and against reference values. Results: In vitro, analog impressions closely matched reference distances, with only the long-span BL-BR showing minor deviation (0.053 mm, p < 0.001). Digital scans showed significantly greater deviations across all spans (max 0.117 mm), particularly over long distances. In vivo, both workflows demonstrated comparable accuracy: only BL-BR (analog) and BR-FR (digital) differed significantly from the reference, and all AMEs remained within clinical thresholds (≤0.10 mm), except for BL-BR and BL-FL spans. ICC values ranged from moderate to high. Direct paired comparisons revealed statistically equivalent performance across most spans. Conclusions: Analog impressions outperformed digital scans in vitro, particularly across longer spans, confirming their superior dimensional fidelity under controlled conditions. However, in vivo, both workflows delivered statistically comparable and clinically acceptable accuracy. These findings suggest that while analog impressions remain the gold standard for precision-demanding contexts, modern intraoral scanners—when used correctly—can offer reliable full-arch mandibular impressions. The four-sphere reference system proved valuable for objective, anatomy-independent measurement.


18 September 2026
Verified
Book Chapter
Closed access
PDF file
MMMircea Muntean
Mircea Muntean
VBVlad Bocanet
Vlad Bocanet
ITIoan Turcin
Ioan Turcin
DFDomnița Frățilă
Domnița Frățilă

18 September 2026
Verified
Book Chapter
Closed access
PDF file
VBVlad Bocanet
Vlad Bocanet
Katarina KostelicKatarina Kostelic
Katarina Kostelic
NPNicolae Alin Panc
Nicolae Alin Panc
HGHarris Gerzic
Harris Gerzic
MMMircea Muntean
Mircea Muntean
CFCristina Fleseriu
Cristina Fleseriu