Ordinarily electronic voltage transformers (EVTs) are calibrated off-line and the calibration procedure requires complex switching operations, which will influence the reliability of the power grid and induce large economic losses. To overcome this problem, this paper investigates a 110 kV on-site calibration system for EVTs, including a standard channel, a calibrated channel and a PC equipped with the LabView environment. The standard channel employs a standard capacitor and an analogue integrating circuit to reconstruct the primary voltage signal. Moreover, an adaptive full-phase discrete Fourier transform (DFT) algorithm is proposed to extract electrical parameters. The algorithm involves the process of extracting the frequency of the grid, adjusting the operation points, and calculating the results using DFT. In addition, an insulated automatic lifting device is designed to realize the live connection of the standard capacitor, which is driven by a wireless remote controller. A performance test of the capacitor verifies the accurateness of the standard capacitor. A system calibration test shows that the system ratio error is less than 0.04% and the phase error is below 2′, which meets the requirement of the 0.2 accuracy class. Finally, the developed calibration system was used in a substation, and the field test data validates the availability of the system.
Transarterial radioembolization (TARE) is a widely utilized therapeutic approach for hepatocellular carcinoma (HCC), however, the clinical implementation is constrained by the stringent preparation conditions of radioembolization agents. Herein, we incorporated the superstable homogeneous iodinated formulation technology (SHIFT), simultaneously utilizing an enhanced solvent form in a carbon dioxide supercritical fluid environment, to encapsulate radionuclides (such as 131I,177Lu, or 18F) with lipiodol for the preparation of radiolipiodol. The resulting radiolipiodol exhibited exceptional stability and ultra-high labeling efficiency (≥99%) and displayed notable intratumoral radionuclide retention and in vivo stability more than 2 weeks following locoregional injection in subcutaneous tumors in mice and orthotopic liver tumors in rats and rabbits. Given these encouraging findings, 18F was authorized as a radiotracer in radiolipiodol for clinical trials in HCC patients, and showed a favorable tumor accumulation, with a tumor-to-liver uptake ratio of ≥50 and minimal radionuclide leakage, confirming the feasibility of SHIFT for TARE applications. In the context of transforming from preclinical to clinical screening, the preparation of radiolipiodol by SHIFT represents an innovative physical strategy for radionuclide encapsulation. Hence, this work offers a reliable and efficient approach for TARE in HCC, showing considerable promise for clinical application (ChiCTR2400087731).
4 April 2021 in Journal of Food Measurement and Characterization
Current transformer measurement errors exhibit strong non-stationarity and multi-scale temporal dynamics, which make accurate prediction challenging for conventional deep learning models. This paper presents a hybrid signal processing and temporal learning framework that integrates ensemble empirical mode decomposition (EEMD) with a dual-scale temporal convolutional architecture. EEMD adaptively decomposes the error sequence into intrinsic mode functions, while a Pearson correlation-based selection step removes redundant and noise-dominated components. The refined signal is then processed by a dual-scale temporal convolutional network (TCN) designed with parallel dilated kernels to capture both high-frequency transients and long-range drift patterns. Experimental evaluations on 110 kV substation data confirm that the proposed decomposition-enhanced dual-scale temporal convolutional framework significantly improves generalization and robustness, reducing the root mean square error by 40.9% and the mean absolute error by 37.0% compared with benchmark models. The results demonstrate that combining decomposition-based preprocessing with multi-scale temporal learning effectively enhances the accuracy and stability of non-stationary current transformer error forecasting.
Capacitor voltage transformers are widely used in 110kV and above power system due to its superiority in economy. The disadvantage is that the measurement error is poor because of CVT is easily affected by multiple influencing factors. It has a certain impact on the safe operation and stable operation of the power grid and effects the fairness of power trading. In this paper, the error state of CVT is mapped to the state evaluation of Q statistics under the constraints of electrical physical relations by principal component analysis. Secondly, the mathematical model between the measurement error of CVT and its influencing factors is analyzed, and the fault tree model suitable for the abnormal analysis of CVT is established. According to the changing form of Q statistics, the location of influence sources is quickly realized when the error exceeding tolerance. The experimental show that this method can accurately evaluate the error state of CVT and accurately diagnose the fault location.