Yang Jiao

Yang Jiao

Auto-generated profile, based on publicly available information

Yang Jiao

Huazhong University of Science and Technology

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
ZZZhu Zhang
Zhu Zhang
HLHongbin Li
Hongbin Li
DTDengping Tang
Dengping Tang
CHChen Hu
Chen Hu
YJYang Jiao
Yang Jiao
Metering performance is the key parameter of an electronic voltage transformer (EVT), and it requires high accuracy. The conventional off-line calibration method using a standard voltage transformer is not suitable for the key equipment in a smart substation, which needs on-line monitoring. In this article, we propose a method for monitoring the metering performance of an EVT on-line based on cyber-physics correlation analysis. By the electrical and physical properties of a substation running in three-phase symmetry, the principal component analysis method is used to separate the metering deviation caused by the primary fluctuation and the EVT anomaly. The characteristic statistics of the measured data during operation are extracted, and the metering performance of the EVT is evaluated by analyzing the change in statistics. The experimental results show that the method successfully monitors the metering deviation of a Class 0.2 EVT accurately. The method demonstrates the accurate evaluation of on-line monitoring of the metering performance on an EVT without a standard voltage transformer.

6 May 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PGPeng-Yu Gu
Peng-Yu Gu
QCQing Chen
Qing Chen
HLHong-Bin Li
Hong-Bin Li
CHChen Hu
Chen Hu
HGHui Gong
Hui Gong
YJYang Jiao
Yang Jiao
In this paper, a measuring system based on Print Circuit Board (PCB) Rogowski coils is introduced for high current measurement with multi-conductor structure. A high current up to 300 kA is split into sixteen branches to fulfill engineering requirements. This high current and multi-split structure bring about many problems into measurement. Traditional Current Transformers (TCTs) are not suitable for this situation since they are saturated by these high currents. A series of PCB-based Rogowski coils is used in the presented system, which can measure this high current easily with high accuracy (<0.5% at Hz). To ensure high accuracy, the measuring system needs to have high uniformity and strong anti-interference ability. Uniformity is analyzed and relevant formula is proposed to calculate it. Anti-interference ability is mainly related to Adjacent Coil’s Mutual Inductance (ACMI), which is analyzed carefully to find variables affect it. Uniformity analysis and anti-interference ability analysis provide a theoretical basis for parameter design. This paper elaborates on parameter design and gives the basis for selecting each parameter, which could be used as a reference for peers. Besides, supporting circuits and frequency analysis are also given to guarantee the integrity of the measuring system. Finally, experiments are carried out to prove high uniformity and anti-interference ability of the measuring system, thus ensuring high measurement accuracy. Tests show that the measurement error can be repressed under 0.5%.

22 November 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JZJing Zhang
Jing Zhang
YJYang Jiao
Yang Jiao
QCQing Chen
Qing Chen
LZLei Zhou
Lei Zhou
HLHongbin Li
Hongbin Li
YTYue Tong
Yue Tong
The deterioration of cable insulation is a widely acknowledged problem, and detection lays the foundation for maintenance and overhaul. The measurement of Tangent delta (tan $\boldsymbol {\delta }$ ) at very low frequency (VLF) works well on cable insulation detection, nevertheless the conventional method could only be conducted offline, where the power outage is usually required, interrupting the normal operation. To break thus a limitation, an advanced online method is proposed, and tan $\boldsymbol {\delta }$ would be calculated based on the measurement of an artificially injected VLF voltage and that of the VLF leakage current through cable insulation. To coordinate with this method, an injecting source, with the comprehensive self-protection and the by-pass channel for power-frequency signals, is developed to safely inject a VLF voltage to the power system, and a monitoring system, with an accuracy better than $\pm 0.3~\boldsymbol {\mu }\text{A}$ , is established to obtain the injected voltage’s and leakage current’s waveforms, which would be used to further calculate tan $\boldsymbol {\delta }$ with the cross-correlation algorithm. In addition, this method, as well as developed devices, is applied on several cables in China Electric Power Research Institute, and the measuring results keep consistent with the actual conditions, which verifies the validity.

27 March 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CHChen Hu
Chen Hu
MCMian-Zhou Chen
Mian-Zhou Chen
HLHong-Bin Li
Hong-Bin Li
ZZZhu Zhang
Zhu Zhang
YJYang Jiao
Yang Jiao
HSHaiming Shao
Haiming Shao
Ordinarily electronic voltage transformers (EVTs) are calibrated off-line and the calibration procedure requires complex switching operations, which will influence the reliability of the power grid and induce large economic losses. To overcome this problem, this paper investigates a 110 kV on-site calibration system for EVTs, including a standard channel, a calibrated channel and a PC equipped with the LabView environment. The standard channel employs a standard capacitor and an analogue integrating circuit to reconstruct the primary voltage signal. Moreover, an adaptive full-phase discrete Fourier transform (DFT) algorithm is proposed to extract electrical parameters. The algorithm involves the process of extracting the frequency of the grid, adjusting the operation points, and calculating the results using DFT. In addition, an insulated automatic lifting device is designed to realize the live connection of the standard capacitor, which is driven by a wireless remote controller. A performance test of the capacitor verifies the accurateness of the standard capacitor. A system calibration test shows that the system ratio error is less than 0.04% and the phase error is below 2′, which meets the requirement of the 0.2 accuracy class. Finally, the developed calibration system was used in a substation, and the field test data validates the availability of the system.

19 August 2019 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
Chuanji ZhangChuanji Zhang
Chuanji Zhang
HLHong-Bin Li
Hong-Bin Li
JYJian Yang
Jian Yang
MCMian-Zhou Chen
Mian-Zhou Chen
YJYang Jiao
Yang Jiao
With the widespread application of capacitor voltage transformers (CVTs) in relaying, power system control and metering, detecting their measurement error drift has become an important and urgent task. Conventional methods are time-consuming and require the power to be cut, while some novel data-driven methods are impractical given their rigorous preconditions. In this paper, an innovative approach is proposed to detect the measurement error drift of CVTs connected to the same phase. Through principal component analysis, both the ratio error drift and the phase displacement drift of the CVT can be detected on-line. Besides the theoretical analysis, a monitoring system equipped with the proposed approach is installed in a 220 kV thermal power plant. The field application indicates it is not only sensitive to the measurement error drift but also good at locating faults.

1 August 2021 in Measurement
Verified
Journal Article
Closed access
YJYang Jiao
Yang Jiao
QCQing Chen
Qing Chen
ZBZhiwei Bao
Zhiwei Bao
LPLinqiang Pan
Linqiang Pan
HLHongbin Li
Hongbin Li