Shuo Wang

Dr. Shuo Wang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2025 in Toxins
Verified
Journal Article
Open access
PDF file
SWShuo Wang
Shuo Wang
HZHuajie Zhang
Huajie Zhang
YXYanhua Xue
Yanhua Xue
YYYingchao Yang
Yingchao Yang
LYLiyong Yuan
Liyong Yuan
Botulinum neurotoxins (BoNTs), produced by the anaerobic spore-forming bacterium Clostridium botulinum, are among the most potent known biological toxins. BoNTs cause lethal botulism via contaminated food, wound infections, or infant intestinal colonization, posing significant threats to public health. Although the mouse bioassay is still being considered as the gold standard for detecting BoNTs, its drawbacks, including the lengthy experimental duration, high costs, and ethical issues, highlight the urgent need to develop alternative methods to fulfill the detection requirements. In recent years, frequent botulism poisoning incidents haves put forward higher requirements for detection technology. On-site detection is expected to be rapid and immediate, while laboratory detection requires high sensitivity and serotype discrimination capabilities. This review comprehensively introduces current detection approaches, including mouse bioassay, cell-based assays, immunological methods, endopeptidase–mass spectrometry, biosensors, chromatography, and mass spectrometry techniques. Notably, cell-based assays have been used for the potency testing of commercialized botulinum toxin type A and are considered the most promising alternative to the mouse bioassay. Biosensors based on nanomaterials demonstrate advantages in real-time detection due to their rapid response and portability, while endopeptidase–mass spectrometry achieves high sensitivity and effective serotype identification by specifically recognizing toxin-cleaved substrates. Future works shall aim to completely replace MBA, developing a detection system suitable for multiple scenarios such as clinical diagnosis, food safety monitoring, and environmental monitoring. The detection methods should also have matrix compatibility and serotype discrimination capabilities.

19 June 2024 in Toxins
Verified
Journal Article
Open access
PDF file
YYYingchao Yang
Yingchao Yang
HZHuajie Zhang
Huajie Zhang
LYLiyong Yuan
Liyong Yuan
SWShuo Wang
Shuo Wang
XMXiao Ma
Xiao Ma
(1) Background: At present, the only potency assay approved in China for the in-country testing of botulinum toxin type A for injection products is the mouse bioassay (MBA). The Chinese market for neurotoxin products is rapidly expanding, but MBAs are subject to high variability due to individual variations in mice, as well as variations in injection sites, in addition to the limited number of batches tested for one MBA. Compared with the mLD50 method, the cell-based potency assay (CBPA) developed for the potency testing of onabotulinumtoxinA (BOTOX) by AbbVie not only does not use any experimental animals but also allows for significant time and cost savings. Due to the significant benefits conferred by the replacement of the mLD50 assay with CBPA in China, the CBPA method has been transferred, validated, and cross-validated to demonstrate the equivalence of the two potency methods. (2) Methods: The differentiated SiMa cells were treated with both BOTOX samples and the reference standard, and the cleaved SNAP25197 in the cell lysates was quantified using Chemi-ECL ELISA. A 4-PL model was used for the data fit and sample relative potency calculation. The method accuracy, linearity, repeatability, and intermediate precision were determined within the range of 50% to 200% of the labeled claim. A statistical equivalence of the two potency methods (CBPA and mLD50) was initially demonstrated by comparing the AbbVie CBPA data with NIFDC mLD50 data on a total of 167 commercial BOTOX lots (85 50U lots and 82 100U lots). In addition, six lots of onabotulinumtoxinA (three 50U and three 100U) were re-tested as cross-validation by these two methods for equivalence. (3) Results: The overall assay’s accuracy and intermediate precision were determined as 104% and 9.2%, and the slope, R-square, and Y-intercept for linearity were determined as 1.071, 0.998, and 0.036, respectively. The repeatability was determined as 6.9%. The range with the acceptable criteria of accuracy, linearity, and precision was demonstrated as 50% to 200% of the labeled claim. The 95% equivalence statistic test using margins [80%, 125%] indicates that CBPA and mLD50 methods are equivalent for both BOTOX strengths (i.e., 50U and 100U). The relative potency data from cross-validation were within the range of ≥80% to ≤120%. (4) Conclusions: The CBPA meets all acceptance criteria and is equivalent to mLD50. The replacement of mLD50 with CBPA is well justified in terms of ensuring safety and efficacy, as well as for animal benefits.

29 December 2025 in Toxins
Verified
Journal Article
Open access
PDF file
YYYingchao Yang
Yingchao Yang
HZHuajie Zhang
Huajie Zhang
SWShuo Wang
Shuo Wang
YXYanhua Xue
Yanhua Xue
LYLiyong Yuan
Liyong Yuan
(1) Background: As an innovative drug derived from botulinum neurotoxin serotype E, TrenibotulinumtoxinE® demonstrates a rapid onset and shorter effect. Due to concerns regarding specificity, test throughput, and animal welfare, a new cell-based potency assay (CBPA) method was developed for BoNT/E drug substance and drug product; independent evaluation of this new CBPA was required. (2) Methods: The CBPA for BoNT/E is a quantitative assay that measures the accumulated cleaved SNAP25180 in human neuroblastoma cells. It involves sequential culturing, differentiation of cells, and then treatment with drug products. Data were analyzed using a quadratic parallel model via statistical software. Linearity was determined using five effective concentration levels. Key assay parameters including accuracy, linearity, repeatability, intermediate precision and range were evaluated. (3) Results: The overall assay’s accuracy was 98%, and the intermediate precision was 6.3%. The coefficient of determination (R2) and slope were determined as 0.963 and 0.942, respectively. The root mean squared error (RMSE) was 0.057, and the intercept was 0.032 for the combined data. The repeatability was 2.4%, which is well within the acceptance criterion of ≤8%. (4) Conclusions: The evaluation was carried out within a single laboratory under controlled conditions; the new CBPA meets all acceptance criteria and can be used for BoNT/E potency determination.