Shuqing Zhang

Dr. Shuqing Zhang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2021 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
HLHong Liang
Hong Liang
Haochen HuaHaochen Hua
Haochen Hua
YQYuchao Qin
Yuchao Qin
MYMaojiao Ye
Maojiao Ye
SZShuqing Zhang
Shuqing Zhang
Junwei CaoJunwei Cao
Junwei Cao
The functionality of energy routing among microgrids is becoming increasingly important with the progress of deploying smart power systems all over the world. For higher energy routing performance and better renewable energy integration, a new type of electrical device, called energy router (ER), is being developed as a part of the infrastructure of the future energy Internet (EI). Generally, the long-term operation of ERs requires an effective energy management scheme for the energy storage inside these devices. In this article, considering the randomness of power generation by renewable energy sources and the stochastic power usage of loads in EI scenario, the compressive sensing is adopted for the solution to the nonlinear energy storage management problem which is essential for the design of ERs. The compressive sensing method used in this article is proven to be more efficient than the conventional Monte–Carlo methods and polynomial chaos expansion method, and the performance of the proposed method is evaluated with numerical examples.

19 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LHLingxi Hou
Lingxi Hou
SZShuqing Zhang
Shuqing Zhang
YWYingdong Wei
Yingdong Wei
BZBiao Zhao
Biao Zhao
QJQirong Jiang
Qirong Jiang
To effectively mitigate the commutation failure (CF) of the line-commutated converter high-voltage direct current (LCC-HVDC) transmission system, a dynamic series voltage compensator (DSVC) scheme is proposed. The DSVC consists of three integrated gate-commutated thyristor (IGCT)-based full-bridge submodule (FBSM) chains to match the bulk power transmission of the LCC-HVDC. Inserted between the transformer and the AC port of the inverter, the DSVC assists the commutation process by superposing the transient voltage to the AC line voltage and increasing the commutation margin of the inverter valve. Operation and control strategies, which are two critical techniques for the DSVC, are designed based on the working states of the FBSMs, assisting the commutation process and balancing the DSVC capacitor dynamic voltages. The CF detection method is another critical technique of the DSVC control and is improved considering the reverse time of the LCC-HVDC thyristors. Compared with the topologies proposed in existing literature, the DSVC has better performances in safe and stable operation due to the urgent control strategy considering situations beyond its ability. A detailed EMT simulation shows that the DSVC can respond quickly to mitigate CFs and validate the effectiveness of the overall design and key techniques. Furthermore, the operation and control strategy can limit the current stress once it is beyond the capability of the DSVC, which guarantees its feasibility and practicability.

8 November 2023 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
SSShanshan Song
Shanshan Song
SZShuqing Zhang
Shuqing Zhang
WDWei Dong
Wei Dong
XZXiaowen Zhang
Xiaowen Zhang
WMWei Ma
Wei Ma

29 June 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LHLingxi Hou
Lingxi Hou
SZShuqing Zhang
Shuqing Zhang
YWYingdong Wei
Yingdong Wei
XLXiaoqian Li
Xiaoqian Li
Qirong JiangQirong Jiang
Qirong Jiang
In this paper, a novel hybrid-arm modular multilevel converters (HA-MMCs) topology with DC low voltage operation and fault ride-through capability is proposed for unidirectional HVDC bulk power transmission. The HA-MMCs topology is a combination of two types of converter arms: the half-bridge sub-module based arm (HBSM-arm) and the diagonal bridge sub-module based arm (DBSM-arm). Replacing the traditional HBSM-MMC, the HA-MMCs are operated in current and reactive power control modes during normal conditions and can work as the rectifier or the inverter. Since the DBSM can provide bipolar voltages with unipolar currents, the HA-MMCs need not change its control strategy under DC low voltage conditions caused by the high-impedance faults. Under DC pole-to-pole or pole-to-ground faults, the HA-MMCs can both clear the DC fault current and work as the static synchronous compensator (STATCOM) to provide reactive power to support the AC grid. Compared with other MMC topologies with DC fault ride-through capability, the HA-MMCs topology is more economical for significantly decreasing the number of power devices. The operation states, control strategy and DC low voltage operation capability of the HA-MMCs are presented and simulation results of the LCC-HA-MMC hybrid system using PSCAD/EMTDC validate the characteristics and advantages of the HA-MMCs.

19 February 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
SYSiqi Yu
Siqi Yu
SZShuqing Zhang
Shuqing Zhang
YWYingdong Wei
Yingdong Wei
YZYanan Zhu
Yanan Zhu
YSYubo Sun
Yubo Sun
Modular multilevel converters (MMCs) play a critical role in the future energy Internet pattern. Therefore, proper models for the simulation of complex systems with multiple MMCs are required. This study proposes a simplified equivalent model (SEM) based on the implicit trapezoidal method and Thevenin equivalent. The model can accurately simulate arm voltages of the MMC and is thus capable of simulating system‐level transients after faults and disturbances, circulating currents and subsynchronous oscillation components. Subsequently, a hybrid model combining SEM and a detailed equivalent model (DEM) is built to improve the overall simulation speed in scenarios where submodule‐level transients are mixed with system‐level ones. Finally, this study notes that the major difference between DEM and SEM results only from the voltage‐balancing cycle. An experiential formula is given to regulate SEM when the voltage‐balancing cycle is large, where the difference may become obvious/insufferable.

6 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
KJKeteng Jiang
Keteng Jiang
HLHaibo Li
Haibo Li
XYXi Ye
Xi Ye
YLYi Lei
Yi Lei
Keng Weng LaoKeng Weng Lao
Keng Weng Lao
XHXianfa Hu
Xianfa Hu
With the advantage of integrating distributed energy, storage and DC load with high efficiency, the DC distribution network recently attracted wide attention in the field of nearly zero energy buildings. Considering the large number of buildings and the enormous energy-saving potential, the distribution form and the revenue distribution are key factors affecting energy efficiency and operational economy. Aiming at the characteristics of AC and DC distribution topologies in nearly zero energy buildings, an energy efficiency evaluation method is proposed based on time-sequential power flow simulation, where the piecewise linear efficiency function of converters and dynamic line power loss model are established. Based on a DC distribution demonstration project, an AC power distribution system with the same boundary conditions is designed. The results show that the efficiency of DC distribution topology is about 6% higher than the AC system, while the efficiency advantage in office, hotel, commercial, educational and residential buildings in Beijing, Shenzhen and Shanghai varies from 0.6–4.96%, which shows a high correlation with the proportion of a high-power load, with Pearson correlation coefficient of 0.794. With the increase of DC load ratio and distributed power supply access capacity, the efficiency of the system will be improved accordingly. On the basis of this, a method to equalize DC distribution income in the nearly zero energy buildings power market is proposed. In addition, 15 typical scenarios of different cities were selected to evaluate efficiency and influencing factors. Finally, assessing the multi-stakeholder impact of DC retrofitting to balance the revenue generated by the DC distribution model suggests that transport costs should be raised by 8.2–13.1% to balance revenue with the equipment prices decreased by about 0.1 yuan/W.