High-voltage dc (HVdc) circuit breakers (CBs) are a key technology of multiterminal dc (MTdc) systems and grids. In this article, a state-of-the-art 500-kV hybrid CB (HCB) topology is proposed and compared with other existing HCB solutions. Implementing the topology includes three important components: a modular designed high-current bidirectional solid-state switch (SS), an ultrafast mechanical switch (MS) based on a Thomson (CCDC) equipment with no conduction loss, whose corresponding functional verification test results have been presented in detail. On this basis, the overall 500-kV HCB and a comprehensive experimental platform are developed. Detailed experiments, including 25-kA turn-off and reclosing experiments, are conducted. The HCB was found to be capable of breaking a 25-kA current in 2.7 ms with 800-kV overvoltage, which is on par with the level of leading CBs worldwide.
2 May 2017 in IEEE Transactions on Power Electronics
This paper gives a comprehensive comparison of multilevel high-frequency-link (HFL) dc transformer (abbreviated MDCT) based on modular multilevel converter (MMC) and multilevel-dc-link dc transformer (abbreviated ADCT) based on dual-active-bridge (DAB) for medium-voltage dc (MVDC) application. The topology, operation, HFL voltage and current, active and circulating power, characteristic currents, switching behaviors, and power loss are analyzed in detail. Both MDCT and ADCT have fault treatment ability for MVDC application. However, the installation and commissioning of ADCT are more flexible and simpler. In addition, the MDCT needs more switches and high-frequency (HF) inductors than ADCT in the MVDC side with the same voltage level, but the number of HF transformer can be reduced. Compared with MDCT, the ADCT has higher power transfer ability and lower circulating power, lower HFL voltage, and RMS current and peak values with the same transmission power in the MVDC side. However, the arm RMS and average currents of MDCT are lower than those of ADCT in the MVDC side. The switching performance of MDCT deteriorates when the MVDC voltage fluctuates, but the switching behaviors of half bridges are added to ADCT. The loss of ADCT almost keep the same when the MVDC voltage fluctuates, but the loss of MDCT changes a lot. Finally, a small-scale prototype platform with 1 kW/450 V/150 V is built and experimental results verify the correctness and effectiveness of the theoretical analysis.
8 September 2021 in IEEE Transactions on Industrial Electronics
DC collection and transmission is one of the main developing directions of the large-scale offshore wind power system. This article proposes a multifunctional dc collector (MDC) to construct a low-cost, high reliability, and high flexibility all-dc offshore wind power system. By introducing the MDC to achieve energy collection and cascade boost, not only the system cost, size, and intermediate links of power conversion are reduced but also the coupling among wind turbines (WTs) is greatly weakened. Accordingly, the maximum power point tracking operation can be achieved independently for each WT unit. Furthermore, a constant voltage ratio control with first harmonic elimination iterative algorithm is proposed for dc collector to link the HVdc bus voltage and discretized dc voltage for triggering the energy consumption operation and suppressing the inductor current ripple, and the detailed control parameter design is provided. Meanwhile, the various operating modes are considered for MDC, including practical engineering configuration, fault isolation, dynamic cut-in/out, and energy consumption operation, which provides a practical solution for the construction of a long-distance and large-capacity offshore system. Finally, the comprehensive experimental results are given to illustrate the effectiveness of MDC.
29 June 2016 in IEEE Transactions on Power Electronics
This paper presents a comprehensive theoretical analysis and experimental verification of high-frequency-link (HFL) modulation of dc-dc transformer (abbreviated as MMDCT) based on the modular multilevel converter (MMC). Three typical HFL dual-active phase-shift modulations are analyzed. Particularly, the HFL voltage, current and power characterization, and different kinds of rating current of the MMDCT during different modulations with the same transmission power are compared comprehensively. On this basis, the detailed switching characterization is presented and the control complexity of the MMDCT during different modulations is discussed. Compared with triangular and sine modulations, square modulation has better HFL and switching performances, especially the control is simpler, which are different with the conclusion in traditional line-frequency ac application of the MMC. At last, experimental results verify the theoretical analysis.
20 December 2018 in IEEE Transactions on Industrial Electronics
Different from the continuous-switching behavior of series power electronic devices in converters, the single-switching attribute of DC breakers (DCBs) provide opportunities to integrate metal oxide varistors (MOVs), balancing circuits and series power power devices. This paper proposes a modular design methodology based on discrete MOVs of DC breaker (DCB) with series power electronic devices. The modular DCB (MDCB) topology and voltage balance issues, the steep front effect and solution, and the design method are proposed and analyzed in this study. Compared with the traditional DCB, the MDCB has self-balancing ability, thereby removing the voltage-balancing circuit and reducing the series module amount. The standard designed cell can be operated as an independent DCB or compose a high-voltage DCB in series flexibly, which decreases the difficulty of design and commission. Finally, a series experimental platform based on IGCT, IGBT, and IEGT is built to verify the correctness and effectiveness of the proposed design methodology.
13 December 2022 in IEEE Transactions on Power Electronics
Medium-voltage large-capacity dc transformer (DCT) is the key energy conversion link for building intelligent distribution grid. Increasing the voltage and capacity of single module in DCT can effectively improve the power density and reduce the system cost. Aiming at the integrated gate commutated thyristor (IGCT)-based high-capacity dc transformer (IGCT–HDCT), the asymmetric topology design and quasi-zero-loss switching composite modulation are proposed to achieve the construction of high efficiency and power density DCT. Through designing the snubber circuit and phase-shift ratio trajectory ingeniously, the zero-voltage switching- on and zero-current switching- off operation of the IGCT–HDCT can be maintained, which greatly reduces the switching loss and gives full play to the extremely low on -state loss characteristics of IGCT. Meanwhile, the full-range soft-switching operation (from no-load to full-load) can be achieved in the composite modulation without adding any auxiliary component. And the design of the snubber circuit is greatly simplified, which cannot only effectively limit the dv / dt and di / dt of power semiconductors, but also improves the power density and operating efficiency of IGCT–HDCT. Finally, the theoretical analysis of the proposed system solution is verified by building a 1.25 MW IGCT–HDCT engineering prototype, and the maximum operating efficiency reaches 98.6%–99.1%.