Corinne Balleyguier

Prof. Dr. Corinne Balleyguier

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2020 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
W(With Language Review By Europa Donna–The European Breast Cancer Coalition For The European Society Of Breast Imaging (Eusobi)
With Language Review By Europa Donna–The European Breast Cancer Coalition For The European Society Of Breast Imaging (Eusobi)
UBUlrich Bick
Ulrich Bick
RTRubina M. Trimboli
Rubina M. Trimboli
AAAlexandra Athanasiou
Alexandra Athanasiou
CBCorinne Balleyguier
Corinne Balleyguier
FSFrancesco Sardanelli
Francesco Sardanelli
We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgical biopsy, we illustrate the criteria used by radiologists for choosing the most appropriate combination of device type for sampling and imaging technique for guidance. Then, we describe the commonly used devices, from fine-needle sampling to tissue biopsy with larger needles, namely core needle biopsy and vacuum-assisted biopsy, and how mammography, digital breast tomosynthesis, ultrasound, or magnetic resonance imaging work for targeting the lesion for sampling or localisation. The differences among the techniques available for localisation (carbon marking, metallic wire, radiotracer injection, radioactive seed, and magnetic seed localisation) are illustrated. Type and rate of possible complications are described and the issue of concomitant antiplatelet or anticoagulant therapy is also addressed. The importance of pathological-radiological correlation is highlighted: when evaluating the results of any needle sampling, the radiologist must check the concordance between the cytology/pathology report of the sample and the radiological appearance of the biopsied lesion. We recommend that special attention is paid to a proper and tactful approach when communicating to the woman the need for tissue sampling as well as the possibility of cancer diagnosis, repeat tissue sampling, and or even surgery when tissue sampling shows a lesion with uncertain malignant potential (also referred to as “high-risk” or B3 lesions). Finally, seven frequently asked questions are answered.

15 June 2021 in Cancers
Verified
Journal Article
Open access
PDF file
YLYingping LI
Yingping LI
SASAMY AMMARI
SAMY AMMARI
CBCorinne Balleyguier
Corinne Balleyguier
NLNathalie Lassau
Nathalie Lassau
ECEmilie Chouzenoux
Emilie Chouzenoux
In brain MRI radiomics studies, the non-biological variations introduced by different image acquisition settings, namely scanner effects, affect the reliability and reproducibility of the radiomics results. This paper assesses how the preprocessing methods (including N4 bias field correction and image resampling) and the harmonization methods (either the six intensity normalization methods working on brain MRI images or the ComBat method working on radiomic features) help to remove the scanner effects and improve the radiomic feature reproducibility in brain MRI radiomics. The analyses were based on in vitro datasets (homogeneous and heterogeneous phantom data) and in vivo datasets (brain MRI images collected from healthy volunteers and clinical patients with brain tumors). The results show that the ComBat method is essential and vital to remove scanner effects in brain MRI radiomic studies. Moreover, the intensity normalization methods, while not able to remove scanner effects at the radiomic feature level, still yield more comparable MRI images and improve the robustness of the harmonized features to the choice among ComBat implementations.

1 May 2014 in European Journal of Radiology
Verified
Journal Article
Closed access
VIVictor Ianculescu
Victor Ianculescu
LCLaura Maria Ciolovan
Laura Maria Ciolovan
ADAriane Dunant
Ariane Dunant
PVPhilippe Vielh
Philippe Vielh
CMChafika Mazouni
Chafika Mazouni
CBCorinne Balleyguier
Corinne Balleyguier

1 June 2023 in Radiology
Verified
Journal Article
Closed access
MBManon P. L. Beuque
Manon P. L. Beuque
MLMarc B. I. Lobbes
Marc B. I. Lobbes
YWYvonka van Wijk
Yvonka van Wijk
YWYousif Widaatalla
Yousif Widaatalla
SPSergey Primakov
Sergey Primakov
Philippe LambinPhilippe Lambin
Philippe Lambin
Background Handcrafted radiomics and deep learning (DL) models individually achieve good performance in lesion classification (benign vs malignant) on contrast-enhanced mammography (CEM) images. Purpose To develop a comprehensive machine learning tool able to fully automatically identify, segment, and classify breast lesions on the basis of CEM images in recall patients. Materials and Methods CEM images and clinical data were retrospectively collected between 2013 and 2018 for 1601 recall patients at Maastricht UMC+ and 283 patients at Gustave Roussy Institute for external validation. Lesions with a known status (malignant or benign) were delineated by a research assistant overseen by an expert breast radiologist. Preprocessed low-energy and recombined images were used to train a DL model for automatic lesion identification, segmentation, and classification. A handcrafted radiomics model was also trained to classify both human- and DL-segmented lesions. Sensitivity for identification and the area under the receiver operating characteristic curve (AUC) for classification were compared between individual and combined models at the image and patient levels. Results After the exclusion of patients without suspicious lesions, the total number of patients included in the training, test, and validation data sets were 850 (mean age, 63 years ± 8 [SD]), 212 (62 years ± 8), and 279 (55 years ± 12), respectively. In the external data set, lesion identification sensitivity was 90% and 99% at the image and patient level, respectively, and the mean Dice coefficient was 0.71 and 0.80 at the image and patient level, respectively. Using manual segmentations, the combined DL and handcrafted radiomics classification model achieved the highest AUC (0.88 [95% CI: 0.86, 0.91]) (P < .05 except compared with DL, handcrafted radiomics, and clinical features model, where P = .90). Using DL-generated segmentations, the combined DL and handcrafted radiomics model showed the highest AUC (0.95 [95% CI: 0.94, 0.96]) (P < .05). Conclusion The DL model accurately identified and delineated suspicious lesions on CEM images, and the combined output of the DL and handcrafted radiomics models achieved good diagnostic performance. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bahl and Do in this issue.

1 December 2017 in European Journal of Radiology
Verified
Journal Article
Closed access
CBCorinne Balleyguier
Corinne Balleyguier
JAJulia Arfi-Rouche
Julia Arfi-Rouche
LLLaurent Levy
Laurent Levy
PTPatrick R. Toubiana
Patrick R. Toubiana
FCFranck Cohen-Scali
Franck Cohen-Scali
BBBruno Boyer
Bruno Boyer

27 June 2016 in The Breast Journal
Verified
Journal Article
Closed access
PDF file
ATAnne-Marie Tardivel
Anne-Marie Tardivel
CBCorinne Balleyguier
Corinne Balleyguier
ADAriane Dunant
Ariane Dunant
SDSuzette Delaloge
Suzette Delaloge
CMChafika Mazouni
Chafika Mazouni
CDClarisse Dromain
Clarisse Dromain
To assess the value on diagnostic and treatment management of contrast-enhanced spectral mammography (CESM), as adjunct to mammography (MG) and ultrasound (US) in postscreening in a breast cancer unit for patients with newly diagnosed breast cancer or with suspicious findings on conventional imaging. Retrospective review of routine use of bilateral CESM performed between September 2012 and September 2013 in 195 women with suspicious or undetermined findings on MG and/or US. CESM images were blindly reviewed by two radiologists for BI-RADS(®) assessment and probability of malignancy. Each lesion was definitely confirmed either with histopathology or follow-up. Two hundred and ninety-nine lesions were detected (221 malignant). CESM sensitivity, specificity, positive-predictive value and negative-predictive value were 94% (CI: 89-96%), 74% (CI: 63-83%), 91% (CI: 86-94%) and 81% (CI: 70-89%), respectively, with 18 false positive and 14 false negative. CESM changed diagnostic and treatment strategy in 41 (21%) patients either after detection of additional malignant lesions in 38 patients (19%)-with a more extensive surgery (n = 21) or neo-adjuvant chemotherapy (n = 1)-or avoiding further biopsy for 20 patients with negative CESM. CESM can be performed easily in a clinical assessment after positive breast cancer screening and may change significantly the diagnostic and treatment strategy through breast cancer staging.