ZHENG QIU

Mr. ZHENG QIU


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MZMeng Zhao
Meng Zhao
MBMaoyong Bai
Maoyong Bai
ZWZhaojun Wu
Zhaojun Wu
SBShaodong Bai
Shaodong Bai
ZQZHENG QIU
ZHENG QIU
HCHongxing Cai
Hongxing Cai
Multispectral temperature measurement technology based on blackbody radiation theory has been widely applied in the field of non-contact temperature measurement. However, its applicability is limited by the single-point measurement mode. To address this limitation, this study developed a spectral fusion temperature measurement device and proposed a new method for reconstructing the two-dimensional temperature field of deflagration fireballs by fusing spectral and imaging data. The device adopts a CCD sensor and a fiber optic spectrometer placed in parallel with parallel optical axes. To ensure the accuracy of the CCD’s response characteristics at different distances, the photo-response non-uniformity (PRNU) calculation method was used for precision validation. In this study, spectral and imaging data of deflagration fireballs were obtained through experiments. Spectral data of consecutive frames at 189 ms, 192 ms, 195 ms, and 198 ms were extracted and analyzed, confirming that the temperature range at the four time points is 1050 K to 1800 K. The proposed method generates temperature elements with equal temperature intervals and their probabilities within the temperature range, and calculates the theoretical radiation spectrum of each element. Then, least squares optimization fitting is performed on the experimentally measured spectra to obtain the optimal probabilities of the temperature elements in the temperature field. By combining these optimal probabilities with CCD grayscale images, the 2D temperature distribution of the deflagration fireball was reconstructed. Results show that: the PRNU value of the device at a distance of 9 m is less than 2.2% through experimental verification; fused images of the temperature field spectra of four consecutive frames of the deflagration fireball were obtained using the proposed method. The average temperatures reconstructed by the proposed method at 189 ms, 192 ms, 195 ms, and 198 ms were 1382 K, 1373 K, 1366 K, and 1357 K, respectively, while the corresponding temperatures obtained by conventional spectral inversion were 1430 K, 1422 K, 1414 K, and 1406 K. The relative errors were 3.2%, 3.4%, 3.3%, and 3.4%, respectively, with an average relative error of approximately 3.3%.

25 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZLZhong Lv
Zhong Lv
ZQZHENG QIU
ZHENG QIU
HSHengyi Sun
Hengyi Sun
JZJianwei Zhou
Jianwei Zhou
JWJianbo Wang
Jianbo Wang
YZYe Zhang
Ye Zhang
This study developed an inertial measurement unit (IMU)-enhanced bidirectional reflectance distribution function (BRDF) imaging system to address angular errors in multi-angle polarimetric measurements. The system integrates IMU-based closed-loop feedback, motorized motion, and image calibration, achieving zenith angle error reduction of up to 1.2° and angular control precision of approximately 0.05°. With a modular and lightweight structure, it supports rapid deployment in field scenarios, while the 2000 mm rail span enables detection of large-scale targets and three-dimensional reconstruction beyond the capability of conventional tabletop devices. Experimental evaluations on six representative materials show that compared with mark-based reference angles, IMU feedback consistently improves polarimetric accuracy. Specifically, the degree of linear polarization (DoLP) mean deviations are reduced by about 5–12%, while standard deviation fluctuations are suppressed by 20–40%, enhancing measurement repeatability. For the angle of polarization (AoP), IMU feedback decreases mean errors by 10–45% and lowers standard deviations by 10–37%, ensuring greater spatial phase continuity even under high-reflection conditions. These results confirm that the proposed system not only eliminates systematic angular errors but also achieves robust stability in global measurements, providing a reliable technical foundation for material characterization, machine vision, and volumetric reconstruction.