Aime Ruus

Prof. Aime Ruus

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2021 in Applied Spectroscopy Reviews
Verified
Journal Article
Open access
FVFlorentina Villanueva
Florentina Villanueva
MRMilagros Ródenas
Milagros Ródenas
ARAime Ruus
Aime Ruus
JSJohn Saffell
John Saffell
MGMarta F. Gabriel
Marta F. Gabriel
Effective evidence-based actions to reduce indoor air pollution must be derived from data obtained using accurate means for assessment of the critical air pollutants and for the identification of their sources. This is of paramount importance to provide robust evidence for establishing effective policies or preventive measures. Nevertheless, designing a reliable sampling plan for assessing concentration of inorganic pollutant in the indoor air requires expertise in conducting rigorous sampling campaigns and proper knowledge on the existing standards and methodologies for assessing concentration of the target substances. Therefore, this review focuses on the relevant information and recommendations that should be considered when designing a sampling plan to collect complementary data on the indoor environment under study, to properly define the criteria for establishing the details for the work and to ensure the quality of the assessments. In particular, comprehensive information on the most commonly used methodologies for the determination of a list of critical inorganic pollutants for indoor air quality monitoring has been compiled. Thus, inorganic gaseous pollutants such as CO2, CO, O3, NO2, NO, NH3, SO2, H2O2, H2S, HNO3 and HNCO are included in the present review.

20 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
MKMihkel Kiviste
Mihkel Kiviste
SMSami Musakka
Sami Musakka
ARAime Ruus
Aime Ruus
JVJuha Vinha
Juha Vinha
Existing buildings are a source of great potential for energy efficiency through renovation. In this study, the national energy requirements equivalent for the major renovation of existing non-residential buildings using the example of office buildings in five European case countries are drawn out and discussed. The non-residential building sector has been found to be complex and heterogenous with much less available data than for the residential sector, but having greater average specific energy consumption per floor area. The existing non-residential building stock in the studied countries has been divided into varying amounts of groups and sub-groups. The energy requirements have been shifting from the increasing requirements for the U-values of the building envelope (before the 2000s) towards calculated energy demand for buildings as a whole (currently). The requirements for buildings in the near future will be carbon emission based. The energy efficiency of N-RBs in all of the studied case countries have been steadily improved during different decades of construction. Relatively older office stock combined with the relatively late introduction of national energy requirements was found to have a significantly larger potential for energy savings. Different terms and contents in national requirements were used to describe the principles of “major renovation” as from EPBD.

18 November 2021 in Applied Spectroscopy Reviews
Verified
Journal Article
Open access
VMVictor G. Mihucz
Victor G. Mihucz
ARAime Ruus
Aime Ruus
JRJane Raamets
Jane Raamets
LWLenka Wimmerová
Lenka Wimmerová
TVTeresa Vera
Teresa Vera
KHKati Huttunen
Kati Huttunen
This review emphasizes the importance of classification of surface reservoirs represented by building and indoor materials. Models developed in the past 45 years to study mainly non-reactive thermodynamic partitioning of air pollutants to surfaces as well as their validation through analytical measurements are discussed. Analytical techniques aiming at surface characterization have been summarized. Applications relevant to surface chemistry performed indoors in the last decade are also given. Finally, techniques for microbiological sampling to characterize the hygienic state of surfaces have also been compiled. Readers will be introduced to the state-of-the-art of analytical techniques that are being used indoors for (physico)chemical and microbiological characterization of surfaces. The focus is on real-time in situ instrumentation used to understand chemical processes rather than air quality monitoring indoors. Our aim was to give an overview of useful instrumentation and a tutorial on analytical approaches and challenges represented by surfaces.

26 November 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
KKKristo Kalbe
Kristo Kalbe
RPRoland Pärn
Roland Pärn
ARAime Ruus
Aime Ruus
TKTargo Kalamees
Targo Kalamees

19 February 2024 in Journal of Sustainable Architecture and Civil Engineering
Verified
Journal Article
Open access
PDF file
APAlois Andreas Põdra
Alois Andreas Põdra
GAGert Air Allas
Gert Air Allas
ARAime Ruus
Aime Ruus
ELElo Lutsepp
Elo Lutsepp
TKTargo Kalamees
Targo Kalamees
The wooden log house serves as a prevalent architectural archetype in rural regions of several Nordic and Baltic countries. To ensure the long-lasting nature of these buildings, proper maintenance is imperative. However, in order to meet the evolving expectations of residents and minimize the environmental impact, a deep renovation is currently required. To successfully achieve the goals of this renovation wave and effectively address the personal needs of the homeowners, it is crucial to develop systemic renovation solutions that can be offered through a digital renovation passport. Consequently, the purpose of this study is to identify common damages, renovation requirements, and evaluate current renovation practices. The findings will serve as a crucial resource for the development of a digital renovation passport. In our study, we utilize rural wooden log houses (comprising 208 houses, 4 years of data) as our research subject. The building elements that are most in need of renovation are the external walls, roofs, and foundations, which require renovation in 77%, 63%, and 63% of the buildings, respectively. The primary cause of damage to the vulnerable structures is excessive moisture. Additionally, decay in the foundation can be attributed to factors such as erosion of mortar, frost, insufficient plinth height, inadequate foundation depth, and inadequate moisture protection. Recommendations provided by consultants primarily focus on restoring and preserving the dwellings' original architectural appearance. As a result, they are deemed insufficient in terms of improving energy performance and indoor climate. This lack of comprehensive consultation is concerning as it fails to consider the potential for cost efficiency, minimizing disruption to occupants, and achieving a comprehensive end result. The absence of recommendations for enhancing indoor climate, energy efficiency, general living quality, and reducing the building's carbon footprint performance the necessity for such renovation solutions and the importance of educating professionals and homeowners. The study's novelty lies in the establishment of statistical probabilities for damages and their causes, as well as the assessment of renovation and maintenance needs and the quality of existing recommendations. Results are scaled to the Estonian building stock, showing the renovation need on national scale. The findings can be incorporated into the digital renovation passport, along with specific renovation goals related to a given house.

30 June 2020
Verified
Conference Paper
Open access
PDF file
MSMihkel Soolepp
Mihkel Soolepp
ARAime Ruus
Aime Ruus
NNNele Nutt
Nele Nutt
JRJane Raamets
Jane Raamets
AKArdo Kubjas
Ardo Kubjas
Paper as a material needs a lot of input energy. Many measures have been suggested to recycle paper, but still a huge amount of it ends in landfills. Hereby, one possibility for recycling paper - making paper plaster and putting it into service in indoor environment - is introduced. The study focuses on the moisture buffering properties of paper plaster. Two questions are under consideration in this article. Firstly, how paper type and production method influence the properties (dry density, drying shrinkage) of paper plaster, and secondly, what the material moisture buffering properties of paper plaster are. The plasters for testing were made from four types of paper (printer paper, glossy paper, newsprint and book paper). The production methods used were rumpling, grinding with a shredder or special crusher (prepared for the study) and soaking the paper after that. The dry density of groups varied from approx. 240 kg/m3 to 400 kg/m3. The shrinkage properties were from 3% to 10% in diameter. To evaluate the moisture buffering ability of paper plaster, the methodology introduced in the Nordtest protocol was used. Paper plaster is an outstanding water vapour buffering material [MBV=2.23-3.91 g/(m2·%RH)] belonging to the moisture buffering class "excellent" defined by Rode [15]. From the production methods rumpling gave the best value while printer paper showed the best values from the chosen materials. The tests with glossy paper resulted in modest values. To conclude, all the paper materials and preparation methods introduced in this study can be used to make paper plaster