Iuliia S. Kakuliia

Mrs. Iuliia S. Kakuliia


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
Alexey ShaposhnikAlexey Shaposhnik
Alexey Shaposhnik
PMPavel V. Moskalev
Pavel V. Moskalev
AVAlexey Vasiliev
Alexey Vasiliev
KOKirill Oreshkin
Kirill Oreshkin
АЗАлексей Алексеевич Звягин
Алексей Алексеевич Звягин
IKIuliia S. Kakuliia
Iuliia S. Kakuliia
In this study, multivariate data processing during thermal modulation of the SnO2–PdO gas sensor was performed using the multivariate calibration (MC) method. We propose to supplement this method with a procedure that allows the solving of problems of both quantitative and qualitative analysis. The advantage of the extended method (Multivariate Calibration for Selective Analysis, MCSA) compared to other methods is its modest requirements for computing resources, which allows it to be easily implemented on standard microcontrollers. The MCSA method opens up the prospect of creating compact gas analyzers of a new generation, capable of selective gas analysis in hard-to-reach places in an autonomous mode. The implementation of the MCSA method was demonstrated using the example of selective determination of hydrogen sulfide and carbon monoxide by a sensor whose temperature periodically changed from 100 to 450 °C. The training sample data were transformed by the MCSA method, which allowed for successful qualitative and quantitative analysis of the test sample data.

28 July 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Alexey ShaposhnikAlexey Shaposhnik
Alexey Shaposhnik
PMPavel V. Moskalev
Pavel V. Moskalev
AVAlexey Vasiliev
Alexey Vasiliev
KOKirill Oreshkin
Kirill Oreshkin
АЗАлексей Алексеевич Звягин
Алексей Алексеевич Звягин
IKIuliia S. Kakuliia
Iuliia S. Kakuliia
Multivariate data processing during thermal modulation of the SnO2–PdO gas sensor was performed using the multivariate calibration (MC) method. We propose to supplement this method with a procedure that allows solving problems of both quantitative and qualitative analysis. The advantage of the extended method (Multivariate Calibration for Selective Analysis, MCSA) compared to other methods is its modest requirements for computing resources, which allows it to be easily implemented on standard microcontrollers. The MCSA method opens up the prospect of creating compact gas analyzers of a new generation capable of selective gas analysis in hard-to-reach places in an autonomous mode. The implementation of the MCSA method was demonstrated using the example of selective determination of hydrogen sulfide and carbon monoxide by a sensor whose temperature periodically changed from 100 to 450 °C. The training sample data were transformed by the MCSA method, which allowed for successful qualitative and quantitative analysis of the test sample data.