Stefan Bogdan

Dr. Stefan Bogdan

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2019 in EP Europace
Verified
Journal Article
Closed access
ENEyal Nof
Eyal Nof
MBMaria Grazia Bongiorni
Maria Grazia Bongiorni
AAAngelo Auricchio
Angelo Auricchio
CBChristian Butter
Christian Butter
NDNikolaos Dagres
Nikolaos Dagres
MGMichael Glikson
Michael Glikson
Aims: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved. Methods and results: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08–1.19), P < 0.0001 and OR 2.68 (1.22–5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04–0.95), P = 0.03 and OR 0.32 (0.13–0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01–4.16), P = 0.046]. Conclusion: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.

7 December 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
MMMiruna Micheu
Miruna Micheu
PNPopa- Fotea Nicoleta-Monica
Popa- Fotea Nicoleta-Monica
NONicoleta Oprescu
Nicoleta Oprescu
SBStefan Bogdan
Stefan Bogdan
MDMonica Dan
Monica Dan
Maria DorobantuMaria Dorobantu
Maria Dorobantu
Background: The aim of this study was to explore the rare variants in a cohort of Romanian index cases with hypertrophic cardiomyopathy (HCM). Methods: Forty-five unrelated probands with HCM were screened by targeted next generation sequencing (NGS) of 47 core and emerging genes connected with HCM. Results: We identified 95 variants with allele frequency < 0.1% in population databases. MYBPC3 and TTN had the largest number of rare variants (17 variants each). A definite genetic etiology was found in 6 probands (13.3%), while inconclusive results due to either known or novel variants were established in 31 cases (68.9%). All disease-causing variants were detected in sarcomeric genes (MYBPC3 and MYH7 with two cases each, and one case in TNNI3 and TPM1 respectively). Multiple variants were detected in 27 subjects (60%), but no proband carried more than one causal variant. Of note, almost half of the rare variants were novel. Conclusions: Herein we reported for the first time the rare variants identified in core and putative genes associated with HCM in a cohort of Romanian unrelated adult patients. The clinical significance of most detected variants is yet to be established, additional studies based on segregation analysis being required for definite classification.

2 June 2014 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
SBStefan Bogdan
Stefan Bogdan
RKRobert Klempfner
Robert Klempfner
ASAvi Sabbag
Avi Sabbag
DLDavid Luria
David Luria
OGOsnat Gurevitz
Osnat Gurevitz
RBRoy Beinart
Roy Beinart

1 June 2012
Verified
Journal Article
Closed access
SBStefan Bogdan
Stefan Bogdan
ASAndrei Seferian
Andrei Seferian
ATAndreea Totoescu
Andreea Totoescu
SDStefan Dumitrache-Rujinski
Stefan Dumitrache-Rujinski
MCMihai Ceausu
Mihai Ceausu
MBMiron Bogdan
Miron Bogdan

Verified
Journal Article
Open access
PDF file
SDSilvia Deaconu
Silvia Deaconu
Alexandru DeaconuAlexandru Deaconu
Alexandru Deaconu
ASAlina Scarlatescu
Alina Scarlatescu
IPIoana Petre
Ioana Petre
Sebastian OnciulSebastian Onciul
Sebastian Onciul
RVRadu Gabriel Vatasescu
Radu Gabriel Vatasescu
Background: We aimed to evaluate whether right ventricle (RV) longitudinal strain indexed to pulmonary arterial systolic pressure (PASP) has prognostic significance in patients undergoing cardiac resynchronization therapy (CRT). Methods: Patients undergoing CRT were prospectively included. The primary endpoint was adverse cardiovascular events (death and HF-related hospitalizations). RV global longitudinal strain (RVGLS) and RV free wall strain (RVfwS) were measured by speckle tracking and indexed to echocardiographic estimated PASP. Results: A total of 54 patients (64.0 ± 13.8 years; 58% male) were included. After 33 ± 12.9 months, the primary endpoint occurred in 18 patients. Baseline RVGLS/PASP and RVfwS/PASP showed good discriminative ability for response to CRT (AUC = 0.88, 95% CI (0.74–1) and AUC = 0.87, 95% CI (0.77–1)). RVGLS/PASP and RVfwS/PASP were significantly associated with high risk of events at univariate analysis (HR 0.039, 95% CI (0.001–0.8) p < 0.05, respectively HR = 0.049, 95% CI (0.0033–0.72), p < 0.05). Upon multivariate Cox regression analysis, RVGLS/PASP and RVfwS/PASP remained associated with high risk of events (HR 0.018, 95% CI (0.0005–0.64), p = 0.02 and HR 0.015, 95% CI (0.0004–0.524), p = 0.01) after correction for gender, etiology, QRS duration and morphology. Conclusions: Indexing RV longitudinal strain (global and free wall) by PASP provides a parameter, which independently identifies patients with high risk of cardiovascular events and predicts non-response to CRT.

9 August 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
SBStefan Bogdan
Stefan Bogdan
Mircea Ioan Alexandru BistriceanuMircea Ioan Alexandru Bistriceanu
Mircea Ioan Alexandru Bistriceanu
Cosmin Gabriel UrsuCosmin Gabriel Ursu
Cosmin Gabriel Ursu
AAAndrei Constantin Anghel
Andrei Constantin Anghel
DADarie-Ioan Andreescu
Darie-Ioan Andreescu
Alexandru DeaconuAlexandru Deaconu
Alexandru Deaconu
Background: Patients with end-stage renal disease (ESRD) are at elevated risk for device-related complications following pacemaker implantation. Leadless pacemakers (LPMs) offer theoretical advantages over transvenous pacemakers (TVPs), but their safety and efficacy in this high-risk population remain unclear. Our aim was to compare clinical outcomes and complication profiles between leadless and transvenous pacemakers in patients with ESRD. Methods: We conducted a systematic review and meta-analysis according to PRISMA guidelines, including three retrospective studies comparing LPMs and TVPs in ESRD patients. The primary endpoint was overall complications post-implantation. Secondary outcomes included early mortality (within 30 days), access site complications, device-related events, thrombotic events, and respiratory complications. A random-effects model was used to pool odds ratios (ORs) and 95% confidence intervals (CIs). Results: Three studies comprising 10.075 ESRD patients were included. No significant difference was found in overall complications (OR 1.35, 95% CI 0.78–2.33, p = 0.14) or early mortality (OR 1.01, 95% CI 0.42–2.43, p = 0.97) between LPM and TVP groups. However, LPMs were associated with increased access site complications (OR 2.51, 95% CI 1.06–5.90, p = 0.04), thrombotic events (OR 1.42, 95% CI 1.14–1.78, p = 0.03), and respiratory complications (OR 1.43, 95% CI 1.01–2.03, p = 0.05). Device-related complication rates were similar (OR, 1.09; 95% CI, 0.63–1.88; p = 0.30). Heterogeneity was low across most outcomes. Conclusions: Among patients with ESRD, leadless pacemakers did not reduce overall complications or short-term mortality compared to transvenous systems and were associated with increased risk of certain procedural complications. These findings could support a personalized approach to device selection in ESRD and highlight the need for further prospective studies to guide clinical decision-making in this population.